Anolis ArcSource Outdoor 24MC Integral

Installation Instructions

Safety Warning

Fixture must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. This device falls under class one and must be grounded!

Mounting Options

STEP 1A: MOUNTING - USING YOKE

Use an Allen key 6 to release M8 tilting lock on each side of luminaire and adjust tilt of LED module in range of +35°/-90°.

Mount the fixture via suitable mounting holes. Ensure that you are mounting the fixture to a secure and non-flammable surface.

Fasten the Yoke of the fixture to the surface by three [screw]s.

STEP 1B: MOUNTING - USING FLOOR STAND

Mount the floor stand to the surface via 4 mounting holes of ⌀9mm or ⌀7mm in diameter.

Mount the luminaire to the Floor stand as illustrated and fasten it by [nut] with [washer] to bolt on floor stand.

Description: ArcSource Outdoor 24MC Integral mounted on the Floor stand.

STEP 1C: MOUNTING - USING LAND SPIKE (100 MM / 130 MM)

Insert the Land Spike into ground. The underground part of Land Spike should be placed perpendicularly into the ground. If tools are needed to insert the spike, use of some protective layer and applying pressure in the middle is recommended to prevent damaging of the land spike.

Mount the luminaire to the Land spike as illustrated and fasten it by two M8x20 [screw]s with [washer]s and spring [washer]s.

Description: ArcSource Outdoor 24MC Integral mounted on the Land Spike.

STEP 1D: MOUNTING USING TENON ADAPTOR (DIAMETER 63 - 80 MM / 80 - 106 MM)

Slide the Tenon Adaptor (mortise) of suitable size on a tenon (e.g., top of a metal post) and fasten in with three [screw]s included in the adapter.

Mount the luminaire to the Tenon Adaptor as illustrated and fasten it by two M8x25 [screw]s with [washer]s and spring [washer]s.

Description: ArcSource Outdoor 24MC Integral mounted on the Tenon Adaptor.

STEP 1E: MOUNTING USING POLE CLAMP (DIAMETER 63 - 80 MM / 80 - 105 MM)

Disassemble the Pole Clamp by unscrewing both [nut]s from bolts.

Mount the Pole Clamp to a pole and fasten it by screwing both [nut]s with [washer]s back to its bolts. Adjust the Pole Clamp to ensure its correct position before tightening it completely.

When in correct position, tighten both [nut]s completely.

Place the luminaire to the Pole Clamp as illustrated and fasten it by two M8x25 [screw]s with [washer]s.

Description: ArcSource Outdoor 24MC Integral mounted on each side of Pole Clamp.

Connection

STEP 2: CONNECTION

Single Luminaire Connection

Connect [DMX] IN and [Power IN] cable to a [Junction Box] and [Power]/data [cable] from the [Junction Box] to the luminaire.

Multiple Luminaire Connection

Use [Power]/data [cable] for connection between [Junction Boxes] as illustrated. Notice the change of connection between the first two and all following junction boxes of the daisy chain line.

Junction Box Installation

Open the [Junction Box] by unscrewing 4 M4x20 [screw]s and lifting up the cover.

Mount the [Junction Box] to a surface via two mounting holes and suitable fasteners.

Wire Stripping and Colour Coding

Wire Stripping Lengths

Power Connection: 9 mm

Data Connection: 7 mm

Power Connection - Power IN Colour Coding
Core (EU)Core (US)LNGROUND
BrownBlackBlueWhiteGreen/YellowGreen
DMX CONNECTION
0 VData GroundD-D+
Data -Data +
Cable CE/US Leader - LED Output
WIREDATA AND POWER CONNECTION
BrownLive
BlueNeutral
Yellow/GreenGround
Red+
White-
Shielding0

Wiring Diagrams

5A: Connection scheme for the installations of single luminaire.

5B: Wiring connection - Daisy chain - First Junction Box. Connection scheme for the first Junction Box in daisy chain line.

5C: Wiring connection - Daisy chain - Following Junction Box. Connection scheme for each following Junction Box in daisy chain line. Only power/data cables are used.

Installation Accessories

STEP 3: INSTALLATION ACCESSORIES

Cable Gland Installation

Use wrench size 24 for cable gland M20x1.5. Install Cable glands individually!

Apply Loctite 5331 thread sealant on the plastic holder and Loctite 577 thread locking compound on the gland body in the indicated locations prior to assembly.

Failure to properly install cable glands will result in failure of the water tight seal!

Closing Junction Box

Install safety cover and top cover back. Before applying the torque, make sure the thread is clean and functional.

Torque: 4x 2 Nm

Top Hat and Half Top Hat

Description: Top Hat and Half Top Hat. (Identical installation instructions)

Installing Half Top Hat

Unscrew 4 M6x12 [screw]s from rear side of the luminaire as highlighted.

Slide the accessory on the luminaire from a side.

Fasten the accessory to the rear side of luminaire with four M6x12 [screw]s and spring [washer]s.

Description: ArcSource Outdoor 24MC Integral with Half Top Hat.

Installing Optical Demo Set

Unscrew two M6x12 [screw]s from the rear side of luminaire as highlighted.

Slide the Optical demo set on the luminaire.

Fasten the accessory to the rear side of luminaire with two original [screw]s and [washer]s.

Slide an optical foil into Optical demo set.

Description: ArcSource Outdoor 24MC Integral with Optical demo set.

Models: Arcsource Outdoor 24MC Integral, Arcsource Outdoor Integral, Arcsource, Outdoor Integral, 24MC Integral, Integral

PDF preview unavailable. Download the PDF instead.

Installation Instructions ArcSource Outdoor 24MC integral v2 February 2022 Adobe PDF Library 16.0.7 Adobe InDesign 17.2 (Windows)

Related Documents

Preview Anolis Calumma M/L/XL SC and MC Installation Instructions
Comprehensive installation guide for the Anolis Calumma M, L, and XL SC and MC lighting fixtures, covering yoke installation, cable gland procedures, DALI and DMX connections, wireless DMX setup, power connections, and accessory installations.
Preview Anolis Calumma M/L/XL SC and MC Installation Instructions
Comprehensive installation guide for Anolis Calumma M, L, and XL SC and MC lighting fixtures. Covers yoke mounting, cable gland installation, DALI, DMX, and Wireless DMX connections, accessory fitting (top hats, optical demo sets), and various pole and surface mounting configurations.
Preview Anolis ArcSource Outdoor 4 MC LED Fixture User Manual
Comprehensive user manual for the Anolis ArcSource Outdoor 4 MC, a Cree MC-E RGBW multichip LED fixture. Includes installation, connection, technical specifications, accessories, and dimensions for professional lighting applications.
Preview Ambiane HP111 Recessed User Manual - Anolis LED Lighting
Comprehensive user manual for the Anolis Ambiane HP111 Recessed LED luminaire, covering installation, technical specifications, DMX/DALI/RDM control, maintenance, and software updates.
Preview Anolis Eminere Series LED Lighting Fixture User Manual
Comprehensive user manual for the Anolis Eminere series of LED lighting fixtures (Eminere 1, 2, 3, 4). Covers safety, installation, technical specifications, connections, booster box usage, maintenance, and accessories.
Preview Anolis AMBIANE AP Installation Instructions
Comprehensive installation guide for the Anolis AMBIANE AP lighting fixture, detailing steps for ceiling mounting, power and data connections, and accessory installation.
Preview Anolis Lyrae XS MC Inground LED Luminaire - Specification Sheet
Detailed specification sheet for the Anolis Lyrae XS MC inground LED luminaire, featuring high light output, various optics, RGBW/RGBA color options, IP68/IK10 rating, and flexible control protocols.
Preview Anolis AMBIANE HP111 Pendant Remote Installation Instructions
Comprehensive installation guide for the Anolis AMBIANE HP111 Pendant Remote, detailing steps for mounting, control unit setup, power and data cable connections, and hanging wire adjustments. Includes safety warnings and technical specifications.