A diagram shows the Anolis AMBIANE AP recessed ceiling light fixture, featuring a circular trim and a ribbed heat sink for thermal management.
Step 1: Ceiling Opening
Step 1.A: Standard Mounting Hole
Diagram showing a circular ceiling opening with a diameter of 212-214 mm for standard mounting.
Prepare mounting hole with diameter between 212-214 mm.
Step 1.B: With Adapter Ring
Diagram showing a larger circular ceiling opening with a diameter of 235-255 mm, and an "ADAPTER RING" below it.
Use of the Adapter ring is recommended in case of a bigger ceiling opening. Refer to Step 6.B before connecting power and data cables.
Step 2: Primary Power Connection
Diagram illustrating primary power connections for the Ambiane Power Rack and Ambiane Power AP, showing terminals for DALI, DMX, Secondary Power, and Primary Power, connecting to the Ambiane AP's control unit.
Install terminal block on power cable (from Ambiane Power Rack or Ambiane Power AP) and connect it to the Primary power connection of Ambiane AP's control unit.
Step 3: Data Connection (DMX or DALI)
Diagram for data connection showing terminal blocks for DALI, DMX, Secondary Power, and Primary Power. A separate diagram details DMX connection terminals: 0V, D-, D+, Data Ground, Data, Data +.
Install terminal blocks on DMX or DALI cables and connect them to the control unit.
DMX Connection Terminals:
- 0V (Ground)
- D-
- D+
- Data Ground
- Data
- Data +
Step 4: Secondary Power Connection (48V)
Diagram showing secondary power (48V) connection with a power cable (red and blue wires) connecting to terminals labeled Secondary Power and Primary Power on the Ambiane AP's control unit.
Install terminal block on power cable for secondary power and connect it to the Secondary power connection of Ambiane AP's control unit.
Step 5: DIP Switch Configuration
Diagram of the control unit showing a DIP SWITCH panel with 12 switches. Instructions mention unscrewing two screws and removing a plastic cover to access it.
Unscrew 2 screws on the control unit and remove the plastic cover.
Set the DIP switches to positions according to your operation mode. The fixture can be controlled by DMX or DALI (switch 11 in OFF position).
Step 6.A: Luminaire Installation (Standard)
Make sure power and data cables are connected.
Diagram illustrating luminaire installation. It shows connecting power and data cables, then inserting the fixture into a 212-214 mm ceiling opening using spring clips.
Lift up spring clips on both sides, insert luminaire into ceiling opening and release spring clips to hold luminaire in place.
Step 6.B: Luminaire Installation with Adapter Ring
Diagrams detailing luminaire installation with an adapter ring. This involves sliding the adapter ring under the control unit and spring clips, then inserting the fixture into a 235-255 mm ceiling opening and securing it with spring clips.
- Slide Adapter ring under the control unit and above both spring clips.
- Lift up both springs and slide Adapter ring under them.
- Adapter ring installed on the luminaire.
- Lift up springs on both sides, insert luminaire into ceiling opening and release springs to hold luminaire in place.
Step 7: Installation of Accessories - Anti-Glare
Diagram showing the installation of the Anti-Glare accessory. The Anti-Glare ring is inserted into the Ambiane AP's reflector until three locks snap into place, then clicked to secure.
Insert the Anti-Glare ring into the Ambiane AP's reflector until three locks snap into slots.
Click on Anti-Glare ring to secure.