INSTALLATION INSTRUCTIONS

AMBIANE AP

A diagram shows the Anolis AMBIANE AP recessed ceiling light fixture, featuring a circular trim and a ribbed heat sink for thermal management.

Step 1: Ceiling Opening

Step 1.A: Standard Mounting Hole

Diagram showing a circular ceiling opening with a diameter of 212-214 mm for standard mounting.

Prepare mounting hole with diameter between 212-214 mm.

Step 1.B: With Adapter Ring

Diagram showing a larger circular ceiling opening with a diameter of 235-255 mm, and an "ADAPTER RING" below it.

Use of the Adapter ring is recommended in case of a bigger ceiling opening. Refer to Step 6.B before connecting power and data cables.

Step 2: Primary Power Connection

Diagram illustrating primary power connections for the Ambiane Power Rack and Ambiane Power AP, showing terminals for DALI, DMX, Secondary Power, and Primary Power, connecting to the Ambiane AP's control unit.

Install terminal block on power cable (from Ambiane Power Rack or Ambiane Power AP) and connect it to the Primary power connection of Ambiane AP's control unit.

Step 3: Data Connection (DMX or DALI)

Diagram for data connection showing terminal blocks for DALI, DMX, Secondary Power, and Primary Power. A separate diagram details DMX connection terminals: 0V, D-, D+, Data Ground, Data, Data +.

Install terminal blocks on DMX or DALI cables and connect them to the control unit.

DMX Connection Terminals:

  • 0V (Ground)
  • D-
  • D+
  • Data Ground
  • Data
  • Data +

Step 4: Secondary Power Connection (48V)

Diagram showing secondary power (48V) connection with a power cable (red and blue wires) connecting to terminals labeled Secondary Power and Primary Power on the Ambiane AP's control unit.

Install terminal block on power cable for secondary power and connect it to the Secondary power connection of Ambiane AP's control unit.

Step 5: DIP Switch Configuration

Diagram of the control unit showing a DIP SWITCH panel with 12 switches. Instructions mention unscrewing two screws and removing a plastic cover to access it.

Unscrew 2 screws on the control unit and remove the plastic cover.

Set the DIP switches to positions according to your operation mode. The fixture can be controlled by DMX or DALI (switch 11 in OFF position).

Step 6.A: Luminaire Installation (Standard)

Make sure power and data cables are connected.

Diagram illustrating luminaire installation. It shows connecting power and data cables, then inserting the fixture into a 212-214 mm ceiling opening using spring clips.

Lift up spring clips on both sides, insert luminaire into ceiling opening and release spring clips to hold luminaire in place.

Step 6.B: Luminaire Installation with Adapter Ring

Diagrams detailing luminaire installation with an adapter ring. This involves sliding the adapter ring under the control unit and spring clips, then inserting the fixture into a 235-255 mm ceiling opening and securing it with spring clips.

  1. Slide Adapter ring under the control unit and above both spring clips.
  2. Lift up both springs and slide Adapter ring under them.
  3. Adapter ring installed on the luminaire.
  4. Lift up springs on both sides, insert luminaire into ceiling opening and release springs to hold luminaire in place.

Step 7: Installation of Accessories - Anti-Glare

Diagram showing the installation of the Anti-Glare accessory. The Anti-Glare ring is inserted into the Ambiane AP's reflector until three locks snap into place, then clicked to secure.

Insert the Anti-Glare ring into the Ambiane AP's reflector until three locks snap into slots.

Click on Anti-Glare ring to secure.

Models: AMBIANE AP LED Lighting, AMBIANE AP, LED Lighting, Lighting

PDF preview unavailable. Download the PDF instead.

Installation Instructions Ambiane AP v2 January 2023 Adobe PDF Library 17.0 Adobe InDesign 18.1 (Windows)

Related Documents

Preview Ambiane HP111 Recessed User Manual - Anolis LED Lighting
Comprehensive user manual for the Anolis Ambiane HP111 Recessed LED luminaire, covering installation, technical specifications, DMX/DALI/RDM control, maintenance, and software updates.
Preview Anolis AMBIANE HP111 Pendant Remote Installation Instructions
Comprehensive installation guide for the Anolis AMBIANE HP111 Pendant Remote, detailing steps for mounting, control unit setup, power and data cable connections, and hanging wire adjustments. Includes safety warnings and technical specifications.
Preview Ambiane TD LED Fixture User Manual and Installation Guide
Comprehensive user manual and installation guide for the Anolis Ambiane TD LED lighting fixture, detailing setup, control protocols (DMX, DALI, 0-10V), technical specifications, and software update procedures.
Preview Anolis Calumma M/L/XL SC and MC Installation Instructions
Comprehensive installation guide for Anolis Calumma M, L, and XL SC and MC lighting fixtures. Covers yoke mounting, cable gland installation, DALI, DMX, and Wireless DMX connections, accessory fitting (top hats, optical demo sets), and various pole and surface mounting configurations.
Preview Anolis Calumma S MC/SC User Manual: Installation, Specifications, and Operation
Comprehensive user manual for Anolis Calumma S MC and Calumma S SC LED lighting fixtures. Covers safety, installation, DMX/DALI control, software updates, technical specifications, and maintenance.
Preview Anolis Lyrae XS MC Inground LED Luminaire - Specification Sheet
Detailed specification sheet for the Anolis Lyrae XS MC inground LED luminaire, featuring high light output, various optics, RGBW/RGBA color options, IP68/IK10 rating, and flexible control protocols.
Preview Anolis Calumma M/L/XL SC and MC Installation Instructions
Comprehensive installation guide for the Anolis Calumma M, L, and XL SC and MC lighting fixtures, covering yoke installation, cable gland procedures, DALI and DMX connections, wireless DMX setup, power connections, and accessory installations.
Preview Anolis ArcSource Outdoor 24MC Integral Installation Instructions
Comprehensive installation guide for the Anolis ArcSource Outdoor 24MC Integral LED luminaire, covering mounting options, electrical connections, and accessory installation. Includes safety warnings and technical specifications.