WARNING: Safety Precautions
To reduce the risk of fire, electric shock, or personal injury:
- We suggest installation by a licensed electrician.
- Please read the instructions carefully and save them for future reference.
- Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
- › Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
- › Place the wall switch in the “OFF” position.
- The mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
- Make sure that the ceiling or wall can stand the weight of the lamp before installation.
- Make sure the voltage you are using is 120V. The maximum wattage is Type T, Max 60W per bulb.
- Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
- When replacing bulbs, you should turn off or unplug the lamp and wait until it is cool, as bulbs get hot quickly.
- The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution, and care must be used with any electrical products.
Finished Product Appearance
The finished product is a chandelier featuring a decorative frame, likely made of metal, designed to hold multiple glass shades. It is intended for ceiling mounting and provides illumination.
Tools Required (Not Included)
- Ladder: A stepladder for reaching the ceiling.
- Philips Head or Flat Blade Screwdriver: For driving screws during assembly and mounting.
- Electrical Tape: For insulating wire connections.
- Pliers: For gripping and manipulating parts.
- Wire Cutter/Stripper: For cutting wires and removing insulation.
Parts List
Parts Type & Quantity Including:
- (C) Single bar (1)
- (D) Green ground screw (1)
- (E) Canopy (1)
- (F) Collar ring (1)
- (G) Collar loop (1)
- (H) Quick link (2)
- (I) Chain (1)
- (J) Loop (1)
- (K) Fixture loop assembly (1)
- (L) Clasp (6)
- (M) Loop rod (3)
- (N) Tube (1)
- (O) Socket assembly (1)
- (P) Iron frame (1)
- (Q) Glass shade (12)
- (R) Bracket (12)
- (S) Washer (24)
- (T) Nut (24)
Accessories & Quantity Enclosed:
- (A) Wire connector (3)
- (B) Mounting screw (2)
- (S) Washer (1) (spare part)
- (T) Nut (1) (spare part)
Assembly & Installation Instructions
Step 1: Pre-installation
Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
Step A1:
1) Screw loop (J) onto fixture loop assembly (K). 2) Screw tube (N) onto the bottom of fixture loop assembly (K) and the top of socket assembly (O).
Step A2:
Open the upper clasps (L), attach fixture loop assembly (K) with loop rods (M).
Step A3:
Open the below clasps (L), attach iron frame (P) with loop rods (M). Close clasps (L).
Step 2: Chain Adjustment
Step B1:
By measuring, determine the correct number of links needed for proper hanging height. Using the chain pliers, disconnect and discard the unwanted part of chain (I).
Step B2:
Attach quick link (H) to chain (I) and loop (J) on the top of fixture loop assembly (K).
Step B3:
Carefully weave the fixture wires through chain (I) in and out of every other link and stop just when you reach the top of chain (I). Gently pull the wires to ensure the wires are not stressed.
Step 3: Turn Off Power
Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.
- › Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
- › Place the wall switch in the “OFF” position.
Step 4: Make Installation
Step C1:
Remove collar ring (F) from collar loop (G). Attach single bar (C) to the outlet box with mounting screws (B). NOTE: the side of single bar (C) marked "GND" must face out.
Step C2:
Raise canopy (E) over collar loop (G) and screw collar ring (F) to measure a proper position. Unscrew collar ring (F) from collar loop (G) and remove canopy (E). Refer to the following note, you would know the proper position where collar loop (G) should be located. NOTE: canopy (E) should be snug against the ceiling and collar loop (G) should be screwed enough threads (no less than 6 threads) on the pre-assembled threaded nipple for more secure hanging. If not, adjust collar loop (G) on single bar assembly (C) by screwing collar loop (G) in or out of single bar (C) until the secure length is achieved.
Step C3:
Pass chain (I) through collar ring (F) and then through canopy (E).
Step C4:
Open quick link (H), attach quick link (H) to collar loop (G). Close quick link (H). Pass the fixture wires through collar loop (G) to the top of the pre-assembled threaded nipple and gently pull to ensure the wires are not stressed.
Step C5:
If needed, shorten the length of fixture wires. At this point, the remaining wire length measured above single bar (C) is at least 6".
Step C6: Make Wire Connections
Connect wires as below wires connection shown. PLEASE NOTE THAT GROUND WIRE IS BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
Connect ground wires: Connect the fixture's ground wire to the green ground screw. Connect the outlet box's ground wire to the green ground screw, using a cupped washer if provided.
Connect other wires: Connect the black or red supply wire to the fixture's black wire (typically a parallel cord that is round and smooth, or insulated wire with a copper conductor). Connect the white supply wire to the fixture's white wire (typically a parallel cord that is square and ridged, or insulated wire with a silver conductor).
Twist wires together with plastic wire connectors until tightly joined. Wrap each connector with approved electrical tape. Be sure that no wire strands are exposed and then carefully tuck all wires into the outlet box.
Step C7:
Raise canopy (E) to the ceiling and secure canopy (E) in place by tightening collar ring (F) onto collar loop (G).
Step C8: Install Glass Shades and Bulbs
- Remove nuts (T) from bracket (R).
- Align nuts (T) with the holes on bracket (R) and then screw nuts (T) into holes with washers (S) to secure glass shades (Q) as shown in the illustration.
- Install bulbs (not included). Please do not exceed the maximum wattage recommended on the socket (60W per bulb).
Final Check
Check everything is already installed properly, then you could turn on the light. Enjoy!
Ordering Parts
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustration when ordering parts.
Cleaning
To clean, wipe the fixture with a soft cloth. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.