Important Safety Instructions
WARNING (To reduce the risk of fire, electric shock, or personal injury):
- Installation by a licensed electrician is suggested.
- Read these instructions carefully and save them for future reference.
- Before starting, NEVER attempt any electrical work without shutting off the electricity.
- Go to the main fuse or circuit breaker box and place the main power switch in the "OFF" position.
- Place the wall switch in the "OFF" position.
- The mounting surface should be clean, dry, flat, and strong enough. It must be at least 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected.
- Ensure the ceiling or wall can support the weight of the lamp before installation.
- Verify the voltage is 120V. The maximum wattage per bulb is Type B, Max 40W.
- Keep the lamp away from acidic and alkaline substances to prevent damage to the lamp's surface.
- When replacing bulbs, turn off or unplug the lamp and wait until it is cool, as bulbs get hot quickly.
- The safety instructions in this manual do not cover all possible conditions. Common sense, caution, and care must be used with any electrical products.
Finished Product
A diagram showing the finished product: a five-light chandelier with glass shades, suspended from a central tube.
Tools Required (Not Included)
Before starting assembly and installation, please prepare the needed tools as shown below:
[Ladder]
Ladder
[Screwdriver]
Philips Head or Flat Blade Screwdriver
[Electrical Tape]
Electrical Tape
[Pliers]
Pliers
[Wire Cutter/Stripper]
Wire Cutter/Stripper
Parts List
Parts Type & Qty Including:
- (C) Mounting plate (1)
- (D) Green ground screw (1)
- (E) Canopy (1)
- (F) Loop (2)
- (G) Ball nut (2)
- (H) Quick link (2)
- (I) Tube
- (J) Socket assembly (1)
- (K) Socket arm (5)
- (L) Socket (5)
- (M) Lampshade (5)
Accessories Enclosed
- (A) Wire connector (3)
- (B) Mounting screw (2)
Assembly & Installation Instructions
- Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the illustration.
Pre-installation Steps
Step A1: 1) Carefully pass the fixture wires through tubes (I) and loops (F). 2) Screw tubes (I) to the top of the socket assembly (J).
Diagram A1: Shows fixture wires being passed through tubes and loops.
Step A2: Open quick links (H). Attach quick links (H) to loops (F) on canopy (E) and on the top of tubes (I). Close quick links (H).
Diagram A2: Illustrates the attachment of quick links to loops on the canopy and tubes.
Power Off Procedure
Before starting the installation, NEVER attempt any work without shutting off the electricity until the work is done.
- Go to the main fuse or circuit breaker box and place the main power switch in the "OFF" position.
- Place the wall switch in the "OFF" position.
Main Installation Steps
Step B1: Unscrew ball nuts (G) from mounting plate (C).
Diagram B1: Shows ball nuts being unscrewed from the mounting plate.
Step B2: Attach mounting plate (C) to the outlet box with mounting screws (B). Note: the side of the mounting plate (C) marked "GND" must face out.
Diagram B2: Depicts the mounting plate being attached to the outlet box with screws, noting the "GND" marking.
Step B3: If needed, shorten the length of fixture wires. Ensure the remaining wire length measured above canopy (E) is at least 6 inches.
Diagram B3: Shows wire length adjustment.
Step B4: Make wire connections.
Connect wires as shown in the connection diagram. PLEASE NOTE THAT THE GROUND WIRE IS BARE COPPER WIRE; NEVER CONNECT OTHER WIRES TO GROUND WIRES.
Diagrams A & B (Ground Connection): Illustrate connecting the outlet box ground to the fixture ground using a green ground screw, with notes on dimples and cupped washers.
Wire Connection Chart Connect Black or Red Supply Wire to: Connect White Supply Wire to: Black White *Parallel cord (round & smooth) *Parallel cord (square & ridged) Clear, Brown, Gold or Black without tracer Clear, Brown, Gold or Black with tracer Insulated wire (other than green) with copper conductor Insulated wire (other than green) with silver conductor * Note: When parallel wires (SPT I & SPT II) are used, the neutral wire is square shaped or ridged, and the other wire will be round or smooth.
- Twist wires together with plastic wire connectors until tightly joined.
- Wrap each connector with approved electrical tape, ensuring no wire strands are exposed.
- Carefully tuck all wires into the outlet box.
Step B5: Raise canopy (E) to the ceiling and secure canopy (E) in place by tightening ball nuts (G) onto the pre-assembled screws on mounting plate (C).
NOTE: Canopy (E) should be snug against the ceiling with ball nuts (G). If not, remove canopy (E) and adjust the threaded length of the pre-assembled mounting screws on mounting plate (C):
- First, unscrew the pre-assembled hex nuts.
- Then, screw the pre-assembled mounting screws in or out of mounting plate (C).
- When the secure length is achieved, tighten the pre-assembled hex nuts and return to Step B5.
Diagram B4 & B5: Show wire connections and canopy attachment/adjustment.
Step B6: 1) Install bulbs (not included). Do not exceed the maximum wattage recommended for the socket. 2) Carefully screw lampshades (M) onto sockets (L) as shown in the illustration.
Diagram B6: Shows bulbs being installed and lampshades being screwed onto sockets.
Final Check
Check that everything is installed properly, then you can turn on the light. Enjoy!
Ordering Parts
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use the exact wording from the illustration when ordering parts.
Cleaning
To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner (such as mild and non-abrasive soap). Do not use abrasive materials such as scouring pads, powders, steel wool, or abrasive paper.