R. STAHL Isolator Barriers

Loop-powered binary output for Ex i field circuit

Model: 9176/20-15-00k | Art. No. 222181

Key Features

The 9176 series binary outputs issue binary signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps, or horns. The devices are powered by the control circuit and feature intrinsically safe outputs that are galvanically separated from the inputs. Two-channel variants have galvanically separated channels.

Technical Data

Explosion Protection

Parameter Value
Application range (zones) 2
Ex interface zone 0, 1, 2, 20, 21, 22
IECEX gas certificate IECEx BVS 13.0012 X
IECEx gas explosion protection Ex nA [ia Ga] IIC T4 Gc
IECEx dust certificate IECEx BVS 13.0012 X
IECEx dust explosion protection [Ex ia Da] IIIC
ATEX gas certificate BVS 04 ATEX E 075 X
ATEX gas explosion protection II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
ATEX dust certificate BVS 04 ATEX E 075 X
ATEX dust explosion protection II (1) D [Ex ia Da] IIIC
FMUS certificate FM16US0122X
CFM certificate FM16CA0067X
Marking cFMus Class I, Div. 2, Groups A,B,C,D;
Class I, Zone 2, Group IIC
AIS Class I,II,III, Div. 1, Groups A,B,C,D,E,F,G;
Class I, Zone 0, [AEx ia]/[Ex ia] IIC
Certificates ATEX (BVS), Brazil (ULB), Canada (FM), China (NEPSI), IECEx (BVS), Korea (KTL), SIL (exida), USA (FM)
Ship approval CCS, EU RO MR (DNV)
Declaration of conformity ATEX (EUK), China (CCC)

Safety Data

Parameter Value
Max. voltage Uo/Voc 27.6 V
Max. current lo (Ex ia) 86.5 mA
Max. current lo (Ex ib) 44 mA
Max. power Po 596 mW
Max. permissible external capacitance C/C for IIC 0.085 μF
Max. permissible external inductance L/La for IIC 1.8 mH
Max. permissible external capacitance C/C for IIB 0.667 μF
Max. permissible external inductance L/La for IIB 17 mH
Internal capacitance 1.1 nF
Internal inductance Negligible
Max. voltage Uo parallel 27.6 V
Max. power Po parallel 1192 mW
Max. current lo (Ex ia) paral. 173 mA
Max. current lo (Ex ib) paral. 88 mA
Internal capacitance parallel 2.2 nF
Internal inductance parallel negligible
Safety-related max. voltage 253 V
Intrinsically safe limiting values inductance L/capacitance C₀ Max. connectable inductance L/capacitance C₀: 2 parallel channels
IIC L₀ [mH] 2.5 mH
IIC C₀ [µF] 0.665 μF
IIB L₀ [mH] 2.500 mH
IIB C₀ [µF] 0.665 μF

Electrical Data

Parameter Value
Number of channels 2
Internal resistance R 320 Ω
Auxiliary Power without
Auxiliary power consumption 0.5 W + (I x 37 mW/mA)
Polarity reversal protection Yes

Galvanic Isolation

Parameter Value
Test voltage as per standard (Ex i input to Ex i input) EN IEC 60079-11
Test voltage as per standard (Input to input) EN 50178
Test voltage 350 V AC

Input

Parameter Value
Input conditions In accordance with EN 61131-2
Input voltage for ON 18 – 31.2 V
Input voltage for OFF 0 – 5 V
Control Power PE 0.5 W + (IA x 37 mW/mA) (with I = max. required output current)

Output

Parameter Value
Output open-circuit voltage U₂ 25 V
Max. output current la max 29 mA
Max. output current I note Parallel channels: 58 mA
Internal resistance R₁ note 320 Ω/parallel: 160 Ω
Output residual ripple < 100 mV
Output switching frequency ≤ 10 Hz
Switching delay ON/OFF ≤ 50 ms
Switching delay OFF/ON ≤ 18 ms

Switching State Indication

Yellow "OUT" LED

9176/.0-15-00 output characteristic

A graphical representation shows two curves, labeled A and B, plotting current [mA] on the x-axis against voltage [V] on the y-axis. Curve A shows the characteristic for each channel, while Curve B shows the characteristic for channel 1 and parallel channel 2 for specific model types.

Ambient Conditions

Parameter Value
Ambient temperature °C (Single device) -20 °C ... 70 °C
Ambient temperature °C (Group assembly) -20 °C ... 60 °C
Ambient temperature °F (Single device) -4 °F ... +158 °F
Ambient temperature °F (Group assembly) -4 °F ... +140 °F
Note on ambient temperature The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide".
Storage temperature °C -40 °C ... 80 °C
Storage temperature °F -40 °F ... +176 °F
Max. relative humidity 95%
Use at the height of < 2000 m
Electromagnetic compatibility Tested to the following standards and regulations: EN 61326-1. For use in industrial areas; NAMUR NE 21

Mechanical Data

Parameter Value
Degree of protection (IP) IP30
Degree of protection (IP) terminals IP20
Fire resistance (UL 94) VO
Enclosure material Polyamide
Grid dimension 17.6 mm
Width 17.6 mm
Width, inches 0.69 in
Height 114.5 mm
Height in inches 4.51 in
Length 128 mm
Length in inches 5.04 in
Weight 180 g
Weight 0.4 lb

Mounting / Installation

Parameter Value
Mounting orientation Horizontal, Vertical
Mounting type DIN rail NS35/15, NS35/7.5
Connection type Spring clamp terminal
Min. rigid conductor cross section 0.2 mm²
Max. rigid conductor cross section 2.5 mm²
Min. flex conductor cross section 0.2 mm²
Max. flex conductor cross section 2.5 mm²
Connection cross-section AWG 24 ... 14

Technical Drawings

9176/.0-15-00 output characteristic

A graphical representation shows two curves, labeled A and B, plotting current [mA] on the x-axis against voltage [V] on the y-axis. Curve A shows the characteristic for each channel, while Curve B shows the characteristic for channel 1 and parallel channel 2 for specific model types.

Connection diagrams

Diagram 1: Hazardous Location (Division 1, Zone 0/1) to Nonhazardous Location (Division 2, Zone 2). Shows Input from Control System to ISpac Isolator, and Output to Field Device.

Diagram 2: Hazardous Location (Division 1, Zone 0/1) to Nonhazardous Location (Division 2, Zone 2). Shows Input from Control System to ISpac Isolator, and Output to Field Device.

Dimensional Drawings

A diagram shows the overall dimensions of the isolator barrier in millimeters and inches. Key dimensions include height (114.5 mm / 4.51 in), width (17.6 mm / 0.69 in), and length (128 mm / 5.04 in). The diagram also indicates compatibility with various ISpac series modules and Fieldbus Power Supply Series 9412.

Accessories

Accessory Art. No.
Transparent cover (For 91xx ISpac modules, Yellow, transparent. Clear identification of the device for SIL applications. Packaging unit: 10 pieces) 200914

Spare Parts

Screw terminal

Description Art. No.
3-pole plug, screw connector, thread: M3, stripping length: 7 mm, color: green 112817
3-pole plug, screw connector, thread: M3, stripping length: 7 mm, color: black 112816
3-pole plug, screw connector, thread: M3, stripping length: 7 mm, color: blue 112818

Screw terminal with test tap

Description Art. No.
3-pole plug with test tap, screw connector, thread: M3, stripping length: 7 mm, colour: black 113005
3-pole plug with test tap, screw connector, thread: M3, stripping length: 7 mm, colour: blue 113004

Spring clamp terminal

Description Art. No.
3-pole plug with test tap, spring clamp connection, stripping length: 10 mm, color: green 112825
3-pole plug with test tap, spring clamp connection, stripping length: 10 mm, color: black 112824
3-pole plug with test tap, spring clamp connection, stripping length: 10 mm, color: blue 112826

R. STAHL, INC. | 13259 N. Promenade Blvd. | Stafford, TX 77477 | Tel. +1 800 782 4357

PDF preview unavailable. Download the PDF instead.

ex-single-data-sheet-loop-powered-binary-output-ex-i-field-circuit-9176-20-15-00k-222181-en-us-rstahl Adobe PDF Library 17.0

Related Documents

Preview R. STAHL 9176A/20-15-00k Galvanic Isolator: Ex i Field Circuit Output
Technical specifications and features of the R. STAHL 9176A/20-15-00k loop-powered binary output Ex i field circuit isolator. Details on safety, electrical characteristics, mechanical properties, and accessories.
Preview R. STAHL 9176/20-15-00s Isolator Barrier: Technical Specifications
Detailed technical specifications for the R. STAHL 9176/20-15-00s loop-powered binary output isolator barrier for Ex i field circuits, including explosion protection, safety data, electrical data, ambient conditions, and mechanical data.
Preview R. STAHL 9176/20-15-00k Loop-Powered Binary Output Isolator for Ex i Field Circuits
Technical specifications and data for the R. STAHL 9176/20-15-00k loop-powered binary output isolator, designed for intrinsically safe operation in Ex i field circuits. Features include suitability for solenoid valves and signaling devices, two-channel variants, and no need for separate auxiliary power.
Preview R. STAHL 9176A Isolator Barriers: Loop-Powered Binary Output for Ex i Field Circuits
Technical specifications and details for the R. STAHL 9176A series isolator barriers, designed for loop-powered binary outputs in Ex i field circuits. Features include intrinsic safety, galvanic separation, and suitability for solenoid valves and signaling devices.
Preview R. STAHL 9176A Isolator Barrier: Loop-Powered Binary Output for Ex i Field Circuits
Detailed technical specifications and data for the R. STAHL 9176A Isolator Barrier, a loop-powered binary output device designed for intrinsically safe operation in Ex i field circuits. Learn about its explosion protection, technical data, safety features, and accessories.
Preview R. STAHL 9176/20-16-00k Loop-Powered Binary Output Isolator for Ex i Field Circuits
Technical data and specifications for the R. STAHL 9176/20-16-00k loop-powered binary output isolator, designed for intrinsically safe operation of Ex i solenoid valves, indicator lamps, and horns. Features include two-channel variants, no auxiliary power requirement, and galvanic separation.
Preview R. STAHL 9176/20-16-00s Loop-Powered Binary Output Isolator Barrier
Technical data and specifications for the R. STAHL 9176/20-16-00s loop-powered binary output isolator barrier for Ex i field circuits. Features include intrinsic safety, galvanic separation, and suitability for solenoid valves and signaling devices.
Preview R. STAHL 9176/20-15-00k Ex i Binary Output Isolator - Technical Specifications
Detailed technical specifications for the R. STAHL 9176/20-15-00k loop-powered binary output Ex i field circuit isolator, including safety data, electrical characteristics, environmental conditions, and mechanical data.