Akuvox EC32 Smart Intercom Quick Guide
Installation
Step-by-step Installation:
- Step 1: Place the EC32 unit in the desired installation location and mark the positions of the four mounting holes from the back cover onto the wall.
- Step 2: Remove the EC32. Use a 3mm diameter drill bit to create the holes. The depth of the holes should accommodate the length of the M4 screws being used.
- Step 3: Insert four M4 self-tapping screws into the wall, leaving approximately 2mm of the screw exposed.
- Step 4: Align the EC32 with the screws and secure it using four M4 self-tapping screws.
- Finish: Installation is complete.
Configuration
Setting up the Akuvox EC32:
- Access the Akuvox Intercom website by launching a browser and entering the IP address of your R29/R20A device. Log in using the default credentials (username: admin, password: admin).
- Configure Lift access control: Navigate to Intercom > Lift Control > Akuvox EC32 Action on the R29/R20A web UI. Enter the username and password for the EC32.
- Set user access rights: On the R29/R20A web UI, go to Intercom > Card Setting. Alternatively, for R29 models, use Intercom > Private Key or Intercom > Face to assign Lift Floor Numbers to specific users.
- Access the EC32 website: Launch a browser and enter the IP address of the EC32. Log in using the default credentials (username: admin, password: 888888).
- Adjust relay delay time: On the EC32 web UI, navigate to the Config page to set the desired intercom open time.
- Disable automatic reboot: On the EC32 web UI, go to Hardware > Device > Restart everyday and disable this feature. It is enabled by default.
Unpacking
What's in the Box:
Before using the device, please verify the contents of the shipped box:
- EC32 Unit x 1
- Key x 1
Note: You will need to provide your own M4x20 self-tapping screws or longer M4 self-tapping screws.
Device Wiring
Connection Diagram:
The device features several connection points:
- Power Supply: Connect to a 12VDC/1A power source.
- Network Port: Connect your network cable (CAT).
- RS485: Connect to RS485+ and RS485- terminals for serial communication.
- 12V Input: A dedicated 12V input terminal.
The device includes terminal blocks numbered 1 through 16 for various connections.
Technical Requirements
- Double-sided black and white printing.
- Material: 120g imported double-sided coated paper.
- Size: 180x130mm.
- Product requires design approval prior to mass production.
Notice Information
Information in this document is believed to be accurate and reliable at the time of printing. This document is subject to change without notice. Updates can be found on the Akuvox website: http://www.akuvox.com.
©Copyright 2021 Akuvox Ltd. All rights reserved.
Manufacturer: AKUVOX (XIAMEN) NETWORKS CO., LTD.
Address: 10/F, NO.56 GUANRI ROAD, SOFTWARE PARK II, XIAMEN 361009, CHINA
Website: www.akuvox.com
Document Metadata
- Document Number: YS32000011
- Revision: V1.0
- Model Number: TZ-SM-002296