MOEN
Buy it for looks. Buy it for life.®
Specifications
[Illustration of a showerhead, handle, and tub spout]
DESCRIPTION
- Metal construction with various finishes identified by suffix
- Includes showerhead, arm, flange and diverter tub spout
OPERATION
- Handle operates counterclockwise through a 270° arc with off at 6 o'clock and maximum hot at the 9 o'clock position. Shut off in clockwise direction.
- Adjustable temperature limit stop to control maximum hot water temperature.
- Pressure balancing mechanism maintains selected discharge temperature to ± 3°.
FLOW
- EP suffix models are limited to 2.0 gpm (7.6 L/min) max for products manufactured prior to June 30, 2018. EP suffix models manufactured after June 30, 2018 are limited to 1.75 gpm (6.7 L/min) max.
CARTRIDGE
- 1222 cartridge design
- Accommodates back to back installations
- Nonmetallic, nonferrous and stainless steel material
STANDARDS
- Third party certified to meet ASME A112.18.1/CSA B125.1 and all applicable requirements referenced therein.
- EP suffix models are third party certified to WaterSense®.
- ADA ☤ for lever handles.
WARRANTY
- Lifetime limited warranty against leaks, drips and finish defects to the original homeowner.
- 10 year limited warranty when used in a multifamily installation.
- 5 year limited warranty when used in a commercial installation.
- Visit www.moen.com/support for complete details and limitations.
Models
- T2842EP series - shower trim only
- T2843EP series - tub/shower trim
Valves
- 62300 series
- 2500 series
[WaterSense logo]
THICK WALL APPLICATION CRITICAL DIMENSIONS
[Diagram showing dimensions for thick wall application. Key dimensions include: 8" (203mm) showerhead diameter, 2-15/16" (75mm) handle height, 7-9/16" (189mm) from finished wall to center of valve, 2-15/16" (75mm) from finished wall to center of tub spout, 2-1/2" MAX (63mm) tub spout length. Also shows 1/2" MIN. CC (13mm) and 5/8" MIN. IPS (16mm) pipe connections.]
THIN WALL APPLICATION
[Diagram showing installation on a thin wall, indicating face of stud and wall line.]
Rev. 12/17