UNICOL

Contact: 01865 767676 | sales@unicol.com | www.unicol.com

UNICOL CP Series Ceiling Mounts

Models: CP1, CP2, CP3, CP4, CP5, CP6, CP8, CP9, CPAV1

WARNING

Please carefully inspect the product before assembling. If you notice any apparent damage, call your carrier claims agent and do not continue the installation until it has been reviewed. Please watch for pinch points. Do not put your fingers between moveable parts. Do not tamper with or disassemble any spring loaded parts. Before installing, make sure that the supporting surface will support five times the combined load of the solution and the hardware. Never exceed the maximum load capacity. Please also layout all components to ensure that you have all of the required parts before proceeding (see BOM list on following page). Use of this product for anything other than its specified use may result in failure or personal injury. This product is intended for indoor use only. We recommend using a qualified trades person for installation. Use an assistant or lifting equipment to lift and position products.

For support, please call: +44 (0)1865 767676 or email: sales@unicol.com

Components

The following ceiling plates are available:

Diagrams show various ceiling mounting plate designs, illustrating their structure and connection points. These are designed to attach to ceilings and support columns or other mounting hardware.

Tools Required

Installers Required

1

Installation Steps

Step 1: Ceiling Mounting

For models (excluding CP5 & CPSC1): Using the 4 ceiling mounting slots, determine where you want to install your mount, mark it, and fix it into position. Please consider cabling and ceiling fixings prior to installation. Ensure the surface is capable of supporting 5x the combined solutions weight.

For model CP5: Using the 8 ceiling mounting slots, determine where you want to install your mount, mark it, and fix it into position. Please consider cabling and ceiling fixings prior to installation. Ensure the surface is capable of supporting 5x the combined solutions weight.

Diagrams illustrate the ceiling plates with multiple mounting points, showing how to position and fix them to the ceiling.

Step 2: Column Attachment

For models (excluding CP3 & CP4): Slide all cabling through the column and through the gap in the ceiling plate socket. Being mindful of the cables, slide the column into the socket, ensuring that the two holes either side align with those on the mount. Using the through bolt, secure the column into place and tighten the two grub screws at the rear.

For models CP3 & CP4: These plates fix directly with socket-ended products such as suspension adapters and PSU mounts. Slide all cabling through the ceiling plate and attachment. Being mindful of the cables, slide the attachment over the stub column, ensuring that the two holes either side align. Using the through bolt, secure the column into place and tighten the two grub screws at the rear.

Diagrams show the process of feeding cables through the column and attaching it to the ceiling plate, highlighting alignment points and securing hardware.

Adjustments

CP6 Tilt Adjust

To adjust the angle of the CP6, slightly loosen the connecting bolt and move the socket to the correct angle. Once set, tighten the bolt to secure.

Diagram illustrates the tilt adjustment mechanism on the CP6.

CP9 Swivel Adjust

The CP9 offers 360° swivel as standard. When it arrives, it will have been tightened with an impact gun, making it stiff to move (to prevent unauthorised movement). To twist as desired, we recommend fitting the columns first.

Diagram illustrates the 360° swivel capability of the CP9.

Models: CP1, CP2, CP3, CP4, CP5, CP6, CP8, CP9, CPAV1, CP1 Anti Vibration Ceiling Plate, CP1, Anti Vibration Ceiling Plate, Vibration Ceiling Plate, Ceiling Plate

File Info : application/pdf, 4 Pages, 450.21KB

PDF preview unavailable. Download the PDF instead.

unicol-cpav1

References

Adobe PDF Library 17.0 Adobe InDesign 19.5 (Windows)

Related Documents

Preview UNICOL CP Series Ceiling Mounts Installation Guide
Installation guide for UNICOL CP1-CP9 and CPAV1 ceiling mounting solutions. Covers safety, tools, components, and step-by-step assembly instructions for professional AV installations.
Preview UNICOL GK Series Projector Mounts Installation Guide (GKC, GK1, GK2, GK3, GK4 with GAP/GAPU)
Comprehensive installation guide for UNICOL GK Series projector mounts, including models GKC, GK1, GK2, GK3, and GK4, designed for use with GAP and GAPU adapter plates. Covers standard, floor, table, wall, truss, and column mounting.
Preview UNICOL SG3/SG4/SG5 Multi-Screen Gantry Installation Guide
Comprehensive installation guide for UNICOL SG3, SG4, and SG5 multi-screen gantry systems, detailing component assembly, screen mounting, and safety precautions for 33-57 inch displays.
Preview UNICOL GC25/GC35 Girder Clamp Installation Guide
Comprehensive installation instructions and safety guidelines for the UNICOL GC25 and GC35 Girder Clamps. Learn how to safely mount your equipment to girders with this robust clamp, supporting up to 120kg.
Preview UNICOL SG3/SG4/SG5 Gantry System Installation Guide
Comprehensive installation guide for UNICOL SG3, SG4, and SG5 multi-screen gantry systems. Learn how to safely mount displays with detailed steps and safety warnings.
Preview UNICOL GKC/GK1/GK2/GK3/GK4 Projector Mount Installation Guide
Comprehensive installation guide for UNICOL GKC, GK1, GK2, GK3, and GK4 projector mounts, including details on using GAP and GAPU adapter plates, mounting options, and safety warnings.
Preview Unicol PSU/PSC/PPSU/VSU Projector Mount Installation Guide
Detailed installation guide for Unicol PSU, PSC, PPSU, and VSU projector mounts, covering components, tools, and step-by-step assembly for various mounting configurations.
Preview UNICOL CT1/CT2 Truss Clamp Installation Guide
Official installation guide for UNICOL CT1 and CT2 truss clamps. Learn how to safely mount your equipment with these heavy-duty clamps, supporting up to 120kg for professional AV and lighting setups.