Mitsubishi Electric MSZ-FT25VGK2 & MUZ-FT25VGHZ2 Air Conditioner Energy Information
This document provides detailed energy efficiency information for the Mitsubishi Electric MSZ-FT25VGK2 indoor unit and MUZ-FT25VGHZ2 outdoor unit.
Product Identification
Indoor Unit Model: MSZ-FT25VGK2
Outdoor Unit Model: MUZ-FT25VGHZ2
Product Type: Room Air Conditioner
Functions: Cooling, Heating
Heating Season: Average (mandatory), Warmer (if designated), Colder (if designated)
Capacity Control: Variable
Energy Efficiency Ratings
Cooling
Seasonal Efficiency (SEER): 8.6
Energy Efficiency Class: A+++
Heating
Average Season (SCOP/A): 4.6
Average Season Energy Efficiency Class: A++
Warmer Season (SCOP/W): 5.8
Warmer Season Energy Efficiency Class: A+++
Colder Season (SCOP/C): 3.5
Colder Season Energy Efficiency Class: A
Technical Specifications
Cooling Capacity
- Design Load (Pdesignc): 2.5 kW
- Declared Capacity at 27°C (Tj=35°C): 2.5 kW
- Declared Capacity at 30°C (Tj=30°C): 1.9 kW
- Declared Capacity at 25°C (Tj=25°C): 1.2 kW
- Declared Capacity at 20°C (Tj=20°C): 1.3 kW
Heating Capacity (Average Season)
- Design Load (Pdesignh): 3.2 kW
- Declared Capacity at -7°C (Tj=-7°C): 2.9 kW
- Declared Capacity at 2°C (Tj=2°C): 1.8 kW
- Declared Capacity at 7°C (Tj=7°C): 1.2 kW
- Declared Capacity at 12°C (Tj=12°C): 1.0 kW
- Bivalent Temperature: -10°C
- Operating Limit Temperature: -25°C
Sound Power Levels
Indoor Unit (LWA): 60 dB(A)
Outdoor Unit (LWA): 60 dB(A)
Environmental Information
Global Warming Potential (GWP): 675 kgCO2eq.
Note on GWP: The GWP value is based on Regulation (EU) No. 517/2014 from IPCC 4th Assessment Report. For Regulation (EU) No. 626/2011, which cites the IPCC Third Assessment Report, Climate Change 2001, the GWP is 550.
Contact Information
For more information, please contact:
MITSUBISHI ELECTRIC CORPORATION SHIZUOKA WORKS
3-18-1, Oshika, Suruga-ku, Shizuoka 422-8528, Japan
E-mail: melshierp@Mitsubishi Electric.co.jp
MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD
Additional Notes
*1 This information is based on COMMISSION REGULATION (EU) No. 206/2012.
*2 SEER/SCOP values are measured based on EN 14825:2016: Testing and rating at part load conditions and calculation of seasonal performance.