Energy Efficiency Information
This section summarizes the energy efficiency ratings for the Mitsubishi Electric MSZ-HR42VF indoor unit and MUZ-HR42VF2 outdoor unit, as per EU regulations.
Function | Model | Rating | Value | Annual Consumption |
---|---|---|---|---|
Cooling | MSZ-HR42VF / MUZ-HR42VF2 | SEER | 6.5 ( | )226 kWh/annum |
Heating (Average) | MSZ-HR42VF / MUZ-HR42VF2 | SCOP/A | 4.3 ( | )927 kWh/annum |
Heating (Warmer) | MSZ-HR42VF / MUZ-HR42VF2 | SCOP/W | 5.2 ( | )427 kWh/annum |
Heating (Colder) | MSZ-HR42VF / MUZ-HR42VF2 | SCOP/C | X | X kWh/annum |
Sound Power Level (Indoor/Outdoor): 60 dB (A) / 64 dB (A)
Detailed Technical Specifications
General Information
- Product: Room Air Conditioner
- Indoor Unit Model: MSZ-HR42VF2 / MSZ-HR42VFK2
- Outdoor Unit Model: MUZ-HR42VF2
- Functions: Cooling (Y), Heating (Y)
- Capacity Control: Variable (Y)
- Refrigerant: R32
- Global Warming Potential (GWP): 675 kgCO2eq. (based on EU 517/2014, IPCC 4th AR)
Cooling Performance
Item | Symbol | Value | Unit | Conditions |
---|---|---|---|---|
Declared Capacity | Pdc | 4.2 | kW | Indoor 27°C (19°C), Outdoor 35°C |
Declared Energy Efficiency Ratio | EERd | 3.1 | - | Indoor 27°C (19°C), Outdoor 35°C |
Declared Capacity | Pdc | 3.1 | kW | Indoor 27°C (19°C), Outdoor 30°C |
Declared Energy Efficiency Ratio | EERd | 4.8 | - | Indoor 27°C (19°C), Outdoor 30°C |
Declared Capacity | Pdc | 2.0 | kW | Indoor 27°C (19°C), Outdoor 25°C |
Declared Energy Efficiency Ratio | EERd | 7.9 | - | Indoor 27°C (19°C), Outdoor 25°C |
Declared Capacity | Pdc | 1.3 | kW | Indoor 27°C (19°C), Outdoor 20°C |
Declared Energy Efficiency Ratio | EERd | 12.7 | - | Indoor 27°C (19°C), Outdoor 20°C |
Heating Performance (Average Season)
Item | Symbol | Value | Unit | Conditions |
---|---|---|---|---|
Declared Capacity | Pdh | 2.9 | kW | Indoor 20°C, Outdoor 7°C |
Declared Coefficient of Performance | COPd | 4.3 | - | Indoor 20°C, Outdoor 7°C |
Declared Capacity | Pdh | 2.6 | kW | Indoor 20°C, Outdoor -7°C |
Declared Coefficient of Performance | COPd | 3.0 | - | Indoor 20°C, Outdoor -7°C |
Declared Capacity | Pdh | 1.6 | kW | Indoor 20°C, Outdoor 2°C |
Declared Coefficient of Performance | COPd | 4.3 | - | Indoor 20°C, Outdoor 2°C |
Declared Capacity | Pdh | 1.1 | kW | Indoor 20°C, Outdoor 7°C |
Declared Coefficient of Performance | COPd | 5.6 | - | Indoor 20°C, Outdoor 7°C |
Declared Capacity | Pdh | 1.0 | kW | Indoor 20°C, Outdoor 12°C |
Declared Coefficient of Performance | COPd | 6.2 | - | Indoor 20°C, Outdoor 12°C |
Bivalent Temperature | Tbiv | -10 | °C | Heating/Average |
Operating Limit Temperature | Tol | -10 | °C | Heating/Average |
Heating Performance (Warmer Season)
Item | Symbol | Value | Unit | Conditions |
---|---|---|---|---|
Declared Capacity | Pdh | 1.6 | kW | Indoor 20°C, Outdoor 2°C |
Declared Coefficient of Performance | COPd | 4.3 | - | Indoor 20°C, Outdoor 2°C |
Declared Capacity | Pdh | 1.1 | kW | Indoor 20°C, Outdoor 7°C |
Declared Coefficient of Performance | COPd | 5.6 | - | Indoor 20°C, Outdoor 7°C |
Declared Capacity | Pdh | 1.0 | kW | Indoor 20°C, Outdoor 12°C |
Declared Coefficient of Performance | COPd | 6.2 | - | Indoor 20°C, Outdoor 12°C |
Bivalent Temperature | Tbiv | 2 | °C | Heating/Warmer |
Operating Limit Temperature | Tol | -10 | °C | Heating/Warmer |
Heating Performance (Colder Season)
Item | Symbol | Value | Unit | Conditions |
---|---|---|---|---|
Declared Capacity | Pdh | X | kW | Indoor 20°C, Outdoor -7°C |
Declared Coefficient of Performance | COPd | X | - | Indoor 20°C, Outdoor -7°C |
Bivalent Temperature | Tbiv | X | °C | Heating/Colder |
Operating Limit Temperature | Tol | X | °C | Heating/Colder |
Power Consumption in Other Modes
Mode | Symbol | Value | Unit |
---|---|---|---|
Off mode | POFF | 4 | W |
Standby mode | PSB | 4 | W |
Thermostat off mode | PTO | 7 | W |
Other Technical Details
Item | Value | Unit |
---|---|---|
Sound Power Level (Indoor) | 60 | dB (A) |
Sound Power Level (Outdoor) | 64 | dB (A) |
Degradation Coefficient (Cooling) | 0.25 | Cdc |
Degradation Coefficient (Heating) | 0.25 | Cdh |
Manufacturer Information
Manufacturer: MITSUBISHI ELECTRIC CORPORATION
Address: SHIZUOKA WORKS, 3-18-1, Oshika, Suruga-ku, Shizuoka 422-8528, Japan
Contact Email: melshierp@MitsubishiElectric.co.jp
Identification and Signature:
Kenichi Saito
Department Manager,
Quality Assurance Department,
Mitsubishi Electric Air Conditioning Systems Manufacturing Turkey Joint Stock Company
(Note: Information based on COMMISSION REGULATION (EU) No. 206/2011 and COMMISSION DELEGATED REGULATION (EU) No. 626/2011, with GWP based on IPCC 4th Assessment Report.)