Product Identification
Indoor Unit Model: MSZ-AP71VG(K)2 / MSZ-AP71VG2
Outdoor Unit Model: MUZ-AP71VG3
This document provides detailed technical specifications for the Mitsubishi Electric MSZ-AP71VG(K)2 indoor and MUZ-AP71VG3 outdoor air conditioning units.
Energy Efficiency Ratings
The energy efficiency of the unit is rated according to European standards.
Cooling
- SEER (Seasonal Energy Efficiency Ratio): 7.2
- Energy Efficiency Class (Cooling): A++
Heating
- SCOP/A (Seasonal Coefficient of Performance - Average Season): 4.4
- Energy Efficiency Class (Heating/Average Season): A+
- SCOP/W (Seasonal Coefficient of Performance - Warmer Season): 5.8
- Energy Efficiency Class (Heating/Warmer Season): A+++
- SCOP/C (Seasonal Coefficient of Performance - Colder Season): X (Not Specified)
- Energy Efficiency Class (Heating/Colder Season): X (Not Specified)
Performance Specifications
Cooling Performance
Declared capacity for cooling at indoor temperature 27(19)°C and outdoor temperature Tj:
- Tj=35°C: 7.1 kW
- Tj=30°C: 5.3 kW
- Tj=25°C: 3.4 kW
- Tj=20°C: 1.5 kW
Declared energy efficiency ratio for cooling at indoor temperature 27(19)°C and outdoor temperature Tj:
- Tj=35°C: EERd 3.6
- Tj=30°C: EERd 5.3
- Tj=25°C: EERd 8.1
- Tj=20°C: EERd 12.4
Heating Performance (Average Season)
Declared capacity for heating/Average season at indoor temperature 20°C and outdoor temperature Tj:
- Tj=-7°C: Pdh 6.0 kW
- Tj=2°C: Pdh 3.7 kW
- Tj=7°C: Pdh 2.4 kW
- Tj=12°C: Pdh 1.7 kW
- Tj=bivalent temperature: Pdh 6.7 kW
- Tj=operating limit: Pdh 5.4 kW
Declared coefficient of performance/Average season at indoor temperature 20°C and outdoor temperature Tj:
- Tj=-7°C: COPd 2.9
- Tj=2°C: COPd 4.2
- Tj=7°C: COPd 5.9
- Tj=12°C: COPd 6.9
- Tj=bivalent temperature: COPd 2.6
- Tj=operating limit: COPd 1.9
Heating Performance (Warmer Season)
Declared capacity for heating/Warmer season at indoor temperature 20°C and outdoor temperature Tj:
- Tj=2°C: Pdh 3.7 kW
- Tj=7°C: Pdh 2.4 kW
- Tj=12°C: Pdh 1.7 kW
- Tj=bivalent temperature: Pdh 3.7 kW
- Tj=operating limit: Pdh 5.4 kW
Declared coefficient of performance/Warmer season at indoor temperature 20°C and outdoor temperature Tj:
- Tj=2°C: COPd 4.2
- Tj=7°C: COPd 5.9
- Tj=12°C: COPd 6.9
- Tj=bivalent temperature: COPd 4.2
- Tj=operating limit: COPd 1.9
Heating Performance (Colder Season)
Declared capacity for heating/Colder season at indoor temperature 20°C and outdoor temperature Tj:
- Tj=-7°C: Pdh X kW
- Tj=2°C: Pdh X kW
- Tj=7°C: Pdh X kW
- Tj=12°C: Pdh X kW
- Tj=bivalent temperature: Pdh X kW
- Tj=operating limit: Pdh X kW
- Tj=-15°C: Pdh X kW
Declared coefficient of performance/Colder season at indoor temperature 20°C and outdoor temperature Tj:
- Tj=-7°C: COPd X
- Tj=2°C: COPd X
- Tj=7°C: COPd X
- Tj=12°C: COPd X
- Tj=bivalent temperature: COPd X
- Tj=operating limit: COPd X
- Tj=-15°C: COPd X
Bivalent and Operating Limit Temperatures
- Bivalent Temperature (Heating/Average): -10°C
- Operating Limit Temperature (Heating/Average): -15°C
- Bivalent Temperature (Heating/Warmer): 2°C
- Operating Limit Temperature (Heating/Warmer): -15°C
- Bivalent Temperature (Heating/Colder): X °C
- Operating Limit Temperature (Heating/Colder): X °C
Energy Consumption
- Annual Electricity Consumption (Cooling): 345 kWh/a
- Annual Electricity Consumption (Heating/Average Season): 2131 kWh/a
- Annual Electricity Consumption (Heating/Warmer Season): 888 kWh/a
- Annual Electricity Consumption (Heating/Colder Season): X kWh/a
Other Items
- Sound Power Level (Indoor/Outdoor): 65/69 dB (A)
- Refrigerant: R32
- Global Warming Potential (GWP): 675 kgCO2eq. (Note: GWP value of 550 is cited for Regulation (EU) No. 626/2011 based on IPCC Third Assessment Report)
- Rated Air Flow (Indoor/Outdoor): 1116/3822 m³/h
- Capacity Control: Variable
Contact Information
For more information, contact:
MITSUBISHI ELECTRIC CORPORATION SHIZUOKA WORKS
3-18-1, Oshika, Suruga-ku, Shizuoka 422-8528, Japan
E-mail: melshierp@Mitsubishi Electric.co.jp
Disclaimer
This information is based on COMMISSION REGULATION (EU) No. 206/2012 and EN 14825:2016 standards. Actual energy consumption depends on usage and location.
Related Documents
![]() |
Mitsubishi Electric MSZ-AP60VG(K)2 Air Conditioner Energy Efficiency Information This document provides detailed energy efficiency information for the Mitsubishi Electric MSZ-AP60VG(K)2 and MUZ-AP60VG2 air conditioning unit, including SEER, SCOP, and sound power levels, along with important environmental considerations regarding refrigerants. |
![]() |
Mitsubishi Electric MSZ-AY20VGK(P)2 Air Conditioner Specifications Detailed technical specifications and energy efficiency information for the Mitsubishi Electric MSZ-AY20VGK(P)2 indoor unit and MUZ-AY20VG2 outdoor unit air conditioner, including SEER, SCOP, sound levels, and refrigerant details. |
![]() |
Mitsubishi Electric MSZ-HR60VF(K)2 Air Conditioner Product Information Technical specifications and energy efficiency data for the Mitsubishi Electric MSZ-HR60VF(K)2 indoor and MUZ-HR60VF2 outdoor air conditioning units, including SEER, SCOP, sound levels, and global warming potential. |
![]() |
Mitsubishi Electric MSZ-HR71VF(K)2 Air Conditioner Specifications Detailed technical specifications and energy efficiency information for the Mitsubishi Electric MSZ-HR71VF(K)2 indoor unit and MUZ-HR71VF2 outdoor unit air conditioner, including SEER, SCOP, sound power levels, and refrigerant information. |
![]() |
Mitsubishi Electric MSZ-AY15VGK(P)2 Air Conditioner Specifications Technical specifications and energy efficiency ratings for the Mitsubishi Electric MSZ-AY15VGK(P)2 indoor and MUZ-AY15VG2 outdoor air conditioning units, including SEER, SCOP, sound levels, and refrigerant information. |
![]() |
Mitsubishi Electric MSZ-HR25VF2 Air Conditioner: Energy Efficiency and Technical Data Detailed energy efficiency ratings (SEER, SCOP) and technical specifications for the Mitsubishi Electric MSZ-HR25VF2/MUZ-HR25VF2 air conditioning unit, including Global Warming Potential (GWP) information and sound levels. |
![]() |
Mitsubishi Electric MSZ-FT50VGK2 Air Conditioner Energy Efficiency This document provides detailed energy efficiency information for the Mitsubishi Electric MSZ-FT50VGK2 indoor unit and MUZ-FT50VGHZ2 outdoor unit air conditioner, including SEER, SCOP, and energy consumption ratings across different operating conditions and seasons. |
![]() |
Mitsubishi Electric MSZ-HR35VF(K)2 Air Conditioner Product Information and Specifications Comprehensive product information and technical specifications for the Mitsubishi Electric MSZ-HR35VF(K)2 indoor unit and MUZ-HR35VF2 outdoor unit air conditioner, detailing energy efficiency (SEER, SCOP), noise levels, capacity, and refrigerant data. |