Mitsubishi Electric Air Conditioner Energy Efficiency Information
Model: MSZ-FT50VGK2 (Indoor Unit) / MUZ-FT50VGHZ2 (Outdoor Unit)
Energy Efficiency Ratings
The following table details the energy efficiency ratings for the Mitsubishi Electric MSZ-FT50VGK2 and MUZ-FT50VGHZ2 air conditioning unit.
Item | Symbol | Cooling | Heating (Average) | Heating (Warmer) | Heating (Colder) |
---|---|---|---|---|---|
Seasonal Efficiency | SEER | 7.2 | - | - | - |
SCOP/A | - | 4.3 | - | - | |
SCOP/W | - | - | 5.5 | - | |
SCOP/C | - | - | - | 3.3 | |
Energy Efficiency Class | SEER | A++ | - | - | - |
SCOP/A | - | A+ | - | - | |
SCOP/W | - | - | A+++ | - | |
SCOP/C | - | - | - | B |
Performance Data
Detailed performance data for cooling and heating modes are provided below.
Cooling Performance
Item | Symbol | Value | Unit |
---|---|---|---|
Design Load | Pdesignc | 5.0 | kW |
Declared Capacity (Indoor 27°C / Outdoor 19°C) | Pdc | 5.0 | kW |
Declared Efficiency Ratio (Indoor 27°C / Outdoor 19°C) | EERd | 8.3 | - |
Declared Capacity (Indoor 27°C / Outdoor 35°C) | Pdc | 5.0 | kW |
Declared Efficiency Ratio (Indoor 27°C / Outdoor 35°C) | EERd | 5.0 | - |
Heating Performance (Average Season)
Item | Symbol | Value | Unit |
---|---|---|---|
Design Load | Pdesignh | 5.0 | kW |
Declared Capacity (Indoor 20°C / Outdoor -7°C) | Pdh | 4.5 | kW |
Declared Coefficient of Performance (Indoor 20°C / Outdoor -7°C) | COPd | 2.5 | - |
Bivalent Temperature | Tbiv | -10 | °C |
Operating Limit Temperature | Tol | -25 | °C |
Heating Performance (Warmer Season)
Item | Symbol | Value | Unit |
---|---|---|---|
Design Load | Pdesignh | 2.7 | kW |
Declared Capacity (Indoor 20°C / Outdoor 2°C) | Pdh | 2.7 | kW |
Declared Coefficient of Performance (Indoor 20°C / Outdoor 2°C) | COPd | 4.4 | - |
Bivalent Temperature | Tbiv | 2 | °C |
Heating Performance (Colder Season)
Item | Symbol | Value | Unit |
---|---|---|---|
Design Load | Pdesignh | 7.4 | kW |
Declared Capacity (Indoor 20°C / Outdoor -7°C) | Pdh | 4.5 | kW |
Declared Coefficient of Performance (Indoor 20°C / Outdoor -7°C) | COPd | 2.5 | - |
Bivalent Temperature | Tbiv | -10 | °C |
Annual Electricity Consumption
Season | Symbol | Value | Unit |
---|---|---|---|
Cooling | QCE | 243 | kWh/a |
Heating/Average | QHE | 1625 | kWh/a |
Heating/Warmer | QHE | 684 | kWh/a |
Heating/Colder | QHE | 4707 | kWh/a |
Other Information
- Sound Power Level (Indoor/Outdoor): 60/64 dB (A)
- Refrigerant: R32
- Global Warming Potential (GWP): 675 kgCO2eq. (based on Regulation (EU) No. 517/2014 from IPCC 4th Assessment Report. For Regulation (EU) No. 626/2011, which cites the IPCC Third Assessment Report, Climate Change 2001, the GWP is 550.)
- Rated Air Flow (Indoor/Outdoor): 840/2412 m³/h
Contact Information
For more information, please contact:
MITSUBISHI ELECTRIC CORPORATION SHIZUOKA WORKS
3-18-1, Oshika, Suruga-ku, Shizuoka 422-8528, Japan
E-mail: melshierp@Mitsubishi Electric.co.jp
Notes
*1 This information is based on the "product information requirement" in COMMISSION REGULATION (EU) No. 206/2012.
*2 SEER/SCOP values are measured based on EN 14825:2016: Testing and rating at part load conditions and calculation of seasonal performance.