SANIVITE/SANIPUMP 2 V35 Installation Guide
Model: V35
Manufacturer: SFA
Product Overview
The SANIVITE/SANIPUMP 2 is a compact wastewater lifting station designed to evacuate greywater from domestic appliances and sanitary fixtures where gravity drainage is not possible. It is suitable for installing under a sink, in a cabinet, or in a utility room.
This guide provides installation instructions and technical specifications for the V35 model.
Typical Installation Scenarios
The SANIVITE/SANIPUMP 2 can be connected to various fixtures, including:
- Washbasins
- Showers
- Bathtubs
- Washing machines
- Bidets
- Sinks
Diagrams illustrate the connection of these appliances to the pump unit, showing inlet and outlet pipe configurations. The system requires a minimum inlet height and a specific discharge pipe diameter (e.g., Ø 40mm Ext for main discharge, Ø 32 mm Ext for smaller inlets).
Installation Procedure
The installation involves several steps, including electrical connection, plumbing, and securing the unit. Key steps are illustrated:
Step 1: Electrical Connection
Ensure the unit is correctly connected to the power supply. Diagrams show correct (✔️) and incorrect (❌) electrical connections.
Step 2: Plumbing Connections
Connect the inlet pipes from sanitary fixtures to the designated inlets on the pump unit. Diagrams show correct (✔️) and incorrect (❌) plumbing configurations, including the use of specific adaptors and clamps.
Step 3: Securing the Unit
The unit should be placed on a stable, level surface. Diagrams show how to attach inlet pipes and discharge pipes using provided parts (e.g., A, B, C, E).
Step 4: Discharge Pipe Installation
Connect the discharge pipe to the pump outlet. Ensure proper pipe routing and connections using clamps (e.g., B, E).
Step 5: Final Assembly
Complete the assembly by attaching any remaining components and ensuring all connections are secure.
Step 6: Venting and Slope
The installation requires a minimum discharge pipe slope of 3% (approximately 1 cm per meter) to ensure proper drainage. The unit must be installed at a minimum height of 15 cm above the floor level to allow for proper connection and maintenance.
Step 7: Inlet Management
Diagrams show how to manage inlets, including the use of non-return valves and preventing backflow. It's important to avoid connecting certain types of waste (e.g., solids, aggressive chemicals) directly to the pump.
Step 8: Securing the Unit (Base)
The unit can be secured to the floor using mounting brackets (F) and screws (H), with rubber pads (G) for vibration dampening.
Included Parts
The installation kit typically includes:
- A: Elbow connector (x1)
- B: Clamps (32x55) (x8)
- C: Clamp (25x32) (x1)
- D: Adaptor (x2)
- E: Flexible hose/pipe section (x3)
- F: Mounting brackets (x2)
- G: Rubber pads (x4)
- H: Screws (x2)
A detailed exploded view diagram shows the internal and external components of the pump unit, with numbered parts for reference.
Technical Specifications
Specification | Value |
---|---|
Model | V35 |
Standard | EN 12050-2 |
Max Temperature | 60°C (5 min/h) |
Voltage | 220-240V |
Frequency | 50-60Hz |
Power | 400W |
Current | 1.7A |
IP Rating | IP44 |
Weight | 6.4 Kg |
Performance Curve
The performance graph illustrates the relationship between the flow rate (Q in L/min) and the head (H in meters). It shows the maximum achievable head for different flow rates, indicating the pump's capacity. For example, at 0 L/min, the maximum head is approximately 8 meters. At 100 L/min, the head is around 4 meters.
Discharge head limits are also indicated: max 10m, max 20m, max 30m, max 40m, max 50m, depending on the application and installation.
Service Helplines and Contact Information
For service and support, please contact the relevant regional office:
France
Tel: 01 44 82 25 55 | Fax: 03 44 94 46 19
United Kingdom
Tel: 08457 650011 (Call from a land line) | Fax: 020 8842 1671
Ireland
Tel: 1850 23 24 25 (LOW CALL) | Fax: + 353 46 97 33 093
Australia
Tel: +1300 554779 | Fax: +61.2.9882.6950
Deutschland
Tel: 0800 82 27 82 0 | Fax: (06074) 30928-90
Italia
Tel: 0382 6181 | Fax: +39 0382 618200
España
Tel: +34 93 544 60 76 | Fax: +34 93 462 1896
Portugal
Tel: +35 21 911 27 85 | Fax: +35 21 957 70 00
Suisse Schweiz Svizzera
Tel: +41 (0)32 631 04 74 | Fax: +41 (0)32 631 04 75
Benelux
Tel: +31 475 487100 | Fax: +31 475 486515
Sverige
Tel: +08-404 15 30
Norge
Tel: +08-404 15 30
Polska
Tel: (+4822) 732 00 33 | Fax: (+4822) 751 35 16
РОССИЯ (Russia)
Tel: (495) 258 29 51 | Fax: (495) 258 29 51
Česká Republika
Tel: +420 266 712 855 | Fax: +420 266 712 856
Türkiye
Tel: +90 212 275 30 88 | Fax: +90 212 275 90 58
Brazil
Tel: (11) 3052-2292
中国 (China)
Tel: +86(0)21 6218 8969 | Fax: +86(0)21 6218 8970
South Africa
Tel: +27 (0) 21 286 00 28
România
Tel: +40 787 634 557 | Email: service@saniflo.ro
For general service information, visit: www.sfa.biz