SFA SANIBEST® PRO B85

Installation and Maintenance Instructions

1. Description

The SANIBEST® PRO B85 macerator pump is manufactured in a factory certified to ISO 9001, ensuring a high level of performance, safety, and reliability when installed and used according to the instructions provided. This device is not intended for use by persons (including children) with limited physical, sensory, or mental abilities, or those lacking experience and knowledge, unless they are supervised and receive necessary instructions from a responsible person. Children should be supervised to ensure they do not play with the device.

2. Applications

This appliance is a compact lift pump unit designed for removing wastewater from a horizontal outlet toilet, shower, bidet, or washbasin (depending on the model). It complies with EN 12050-3 and European standards for electrical safety and electromagnetic compatibility.

3. Installation

The unit should be installed in the same room as the toilet and any other connected sanitary appliances. It must be easily accessible for inspection and maintenance. Installation and operation must comply with local regulations and EN 12056-4. To optimize acoustic performance, it is important to:

Electrical Connection

Connect the electrical supply only after all water connections are finalized. Electrical installation must be carried out by a qualified person. The unit must be placed so the power socket is accessible. The power supply circuit must be earthed (Class I) and protected by a high-sensitivity residual current device (30mA). Warning: Ensure the electricity is turned OFF at the main switchboard before wiring to the connector. All wiring must conform to BS7671 requirements for electrical installations. Do not connect the unit to a conventional plug and socket; it must be wired into a fused, unswitched, fixed wiring connector fitted with a 5-amp fuse.

4. Commissioning

Flush the toilet several times, checking that all seals and connections are watertight. Verify the watertightness of connections with sanitary appliances: toilet, shower, bidet, or washbasin (depending on the model).

5. Maintenance

WARNING!!! In case of prolonged absence, it is essential to turn off the water supply and protect the installation against freezing.

Cleaning/Descaling

To descale and clean the macerator and the bowl, regularly use a suitable descaling product, such as the SFA SANIBROYEUR Cleanser/Descalent, designed to remove scale while respecting the internal components of the unit.

6. Troubleshooting

IN ALL CASES, DISCONNECT THE MACERATOR FROM THE POWER SUPPLY BEFORE PERFORMING ANY INTERVENTION.

Symptom Probable Cause Remedy
Motor does not start Electrical power supply is not active or is defective. Restore electrical supply or check the electrical power supply. If the problem persists, consult an approved repair agent.
Motor emits a rattling or crunching sound, hums, but does not run Motor or control system defect; Foreign object blocking the motor. Remove the foreign object. If the problem persists, consult an approved repair agent.
Unit intermittently activates Motor or control system defect. Consult an approved repair agent.
Motor operates normally but continues to run for a long time or does not stop Connected sanitary appliances are dripping; Non-return valve is faulty; Discharge height or length is excessive, or too many bends (pressure loss); Unit has been running for too long (thermal cut-out). Check upstream installation; Clean or replace the non-return valve; Re-evaluate the installation; Consult an approved repair agent if necessary; Wait for reset.
Unit stops Thermal cut-out activated. Wait for the unit to reset. If the problem persists, consult an approved repair agent.
Motor is surging and water in the WC pan goes down very slowly Air vent is clogged up; Motor problem; Shower installed too low relative to the macerator. Clear the air vent hole; Consult an approved repair agent; Check the installation.
Cloudy water comes up into the shower basin (units with side inlets) Hinged side inlet discs clogged up. Clean the hinged discs. If the problem persists, consult an approved repair agent.

7. Guarantee

The appliance is guaranteed for two years from the date of purchase, provided it is installed and used in accordance with this manual. The guarantee covers only the disposal of toilet paper, faecal matter, and sanitary wastewater. Damage caused by foreign bodies such as cotton, tampons, sanitary towels, wet wipes, food, hair, metal, wood, or plastic objects, or by pumping liquids such as solvents or oils, will invalidate the guarantee.

Company Information and Service Helplines

Various SFA branches and service helplines are listed for different countries, including France, United Kingdom, Ireland, Australia, Germany, Italy, Spain, Portugal, Switzerland, Benelux, Sweden, Norway, Poland, Russia, Czech Republic, Romania, Turkey, China, Korea, and South Africa. Contact details include telephone and fax numbers. Service information is available at www.sfa.biz.

PDF preview unavailable. Download the PDF instead.

090924-manual sanibest-pro Adobe InDesign CS6 (Windows) Acrobat Distiller 9.2.0 (Windows)

Related Documents

Preview SFA Sanibest Pro Installation and Maintenance Manual
Comprehensive guide for the SFA Sanibest Pro macerator pump, covering installation, operation, maintenance, and troubleshooting. Includes multilingual instructions and safety information.
Preview SFA Saniaccess 3 Installation and User Manual
This document provides installation, operation, and maintenance instructions for the SFA Saniaccess 3 macerator pump unit. It covers safety warnings, applications, installation guidelines, electrical connections, commissioning, troubleshooting, and warranty information.
Preview SFA Sanidouche, Sanishower, Sanipump Installation Guide
Comprehensive installation instructions and technical specifications for SFA Sanidouche, Sanishower, and Sanipump macerator pumps. Includes diagrams, part lists, and contact information for global service.
Preview SFA Sani-Access Installation and Maintenance Manual
Comprehensive guide for the installation, operation, and maintenance of SFA Sani-Access 1 and Sani-Access 2 macerator units. Includes troubleshooting, safety warnings, and warranty information.
Preview SANIPACK/SANINSIDE Macerator Pump Installation and Maintenance Manual
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of SANIPACK/SANINSIDE compact lift pumps. Designed for efficient waste water removal from horizontal outlet toilets, showers, bidets, and washbasins, these SFA macerator pumps ensure reliable performance when installed and used correctly.
Preview SFA Sanivite/Sanipump 2 Installation and Operation Manual
This document provides installation instructions, technical specifications, and contact information for the SFA Sanivite/Sanipump 2 macerator pump.
Preview SFA Sanidouche Flat Installation Guide
Comprehensive installation instructions for the SFA Sanidouche Flat macerator pump, including diagrams, technical specifications, and contact information for global support.
Preview SFA Sanimulti Macerator Pump: Operating and Installation Manual
Detailed operating and installation guide for the SFA Sanimulti macerator pump (model SA222), covering safety, technical specifications, installation procedures, troubleshooting, and warranty information.