SFA Sanidouche, Sanishower, Sanipump Installation Guide

Model: D60

Standard: EN 12050-2

Electrical: 220-240 V - 50 Hz, 250 W - 1.3 A - IP44 - Class 1

Weight: 3.5 KG

Product Overview

The SFA Sanidouche, Sanishower, and Sanipump are designed for lifting wastewater from sanitary facilities. They are compact and efficient units suitable for various installations.

Key Features:

Installation Diagrams and Instructions

The following diagrams illustrate the recommended installation procedures:

Diagram 1: General Installation Layout

Illustrates the basic setup for connecting sanitary appliances to the SFA unit. Shows correct and incorrect pipe routing.

Step 1: Connect the waste pipe from the sanitary appliance to the appropriate inlet on the SFA unit. Ensure correct pipe diameter (e.g., 40mm) and slope. Avoid sharp bends.

Step 2: Connect the discharge pipe to the SFA unit. Ensure the discharge pipe has a suitable diameter (e.g., 22/32mm or 32/40mm) and is routed correctly to the main sewage system.

Step 3: Verify the electrical connection is safe and according to local regulations.

Step 4: Check the maximum vertical and horizontal discharge distances. The unit can pump water up to 4 meters vertically and 40 meters horizontally (with a 1% slope). Note the maximum head and distance limitations indicated by percentage slopes.

Diagram 2: Installation Steps

Provides a step-by-step visual guide for assembling and connecting the unit.

Step 1: Prepare the inlets. For a 22mm pipe, use part C and clamp B. For a 32mm pipe, use part A and clamp C.

Step 2: Attach the discharge pipe using part F and D.

Step 3: Connect the discharge pipe to the unit using part F.

Step 4: Connect the 40mm discharge pipe using part E and clamp F.

Step 5: Connect the 32mm discharge pipe using part E and clamp F.

Step 6: Secure the unit using screws G and H.

Step 7: Ensure the unit is stable and properly positioned.

Step 8: Final check of all connections and ensure no leaks.

Diagram 3: Unit Dimensions and Technical Data

Shows the physical dimensions of the unit and important technical specifications.

Dimensions:

  • Height: 214 mm
  • Width: 356 mm
  • Depth: 294 mm
  • Overall height with connections: 144 mm
  • Outlet height: 74 mm
  • Inlet height: 150 mm

Performance Chart:

A chart shows the relationship between flow rate (L/min) and discharge head (meters). For example, at 50 L/min, the maximum head is approximately 2 meters. At 20 L/min, the maximum head is approximately 4 meters.

Slope Recommendations:

  • Minimum slope for discharge pipe: 1% (1 cm per meter).
  • Maximum vertical lift: 4 meters.
  • Maximum horizontal run: 40 meters (with 1% slope).

Parts List

The following parts are included or required for installation:

Refer to the exploded view diagram for detailed part identification.

Exploded View Diagram

The exploded view diagram shows all internal and external components of the SFA unit, with corresponding part numbers for reference and replacement.

Key Components:

Contact and Service Information

Service Helplines

France: TEL 0810 05 90 02 / FAX 03 44 94 46 19

United Kingdom: TEL 08457 650011 / FAX 020 8842 1671

Ireland: TEL 1850 23 24 25 / FAX +353 46 97 33 093

Australia: TEL +1300 554 779 / FAX +61.2.9882.6950

Germany: TEL 0800 82 27 82 0 / FAX (060 74) 30928-90

Italia: TEL 0382 6181 / FAX +39 0382 618200

España: TEL +34 93 544 60 76 / FAX +34 93 462 18 96

Portugal: TEL +35 21 911 27 85 / FAX +35 21 957 70 00

Suisse Schweiz Svizzera: TEL +41 (0)32 631 04 74 / FAX +41 (0)32 631 04 75

Benelux: TEL +31 475 487100 / FAX +31 475 486515

Sverige: TEL +46 (0)8-404 15 30

Norge: TEL +46 (0)8-404 15 30

Polska: TEL (+4822) 732 00 33 / FAX (+4822) 751 35 16

Česká Republika: TEL +420 266 712 855 / FAX +420 266 712 856

România: TEL +40 256 245 092 / FAX +40 256 245 029

Türkiye: TEL +90 212 275 30 88 / FAX +90 212 275 90 58

China: TEL +86(0)21 6218 8969 / FAX +86(0)21 6218 8970

Brazil: TEL +55 11 3262 2903

Russia: TEL (495) 258 29 51 / FAX (495) 258 29 51

For more service information, visit: www.sfa.fr

PDF preview unavailable. Download the PDF instead.

enk2x8z9c3w3nzbxg3ee2a7wpb22wf3l Adobe InDesign CS6 (Windows) Adobe PDF Library 10.0.1

Related Documents

Preview SFA Sanidouche/Sanishower/Sanipump Installation and User Manual
Comprehensive guide for installing and using SFA Sanidouche, Sanishower, and Sanipump wastewater lifting stations. Includes safety, applications, maintenance, troubleshooting, and technical specifications.
Preview SFA Sanidouche, Sanishower, Sanipump Installation and User Manual
Comprehensive guide for the installation, operation, maintenance, and troubleshooting of SFA Sanidouche, Sanishower, and Sanipump wastewater lifting stations. Covers product features, safety instructions, and technical specifications.
Preview SFA Sanidouche Flat Installation Guide
Comprehensive installation instructions for the SFA Sanidouche Flat macerator pump, including diagrams, technical specifications, and contact information for global support.
Preview Guide d'installation SFA SANIDOUCHE, SANISHOWER, SANIPUMP
Ce manuel fournit des instructions complètes pour l'installation, l'utilisation et la maintenance des stations de relevage SFA SANIDOUCHE, SANISHOWER et SANIPUMP. Il détaille les applications, les raccordements électriques, les procédures de dépannage et les conditions de garantie, assurant une performance optimale et sécurisée.
Preview SFA Sanivite/Sanipump 2 Installation and Operation Manual
This document provides installation instructions, technical specifications, and contact information for the SFA Sanivite/Sanipump 2 macerator pump.
Preview SFA SANIBEST® PRO B85 Installation and Maintenance Manual
This document provides comprehensive installation, operation, and maintenance instructions for the SFA SANIBEST® PRO B85 macerator pump. It covers safety precautions, applications, installation steps, electrical connections, troubleshooting, and warranty information.
Preview SFA Sanimulti Macerator Pump: Operating and Installation Manual
Detailed operating and installation guide for the SFA Sanimulti macerator pump (model SA222), covering safety, technical specifications, installation procedures, troubleshooting, and warranty information.
Preview SFA Sanibest Pro Installation and Maintenance Manual
Comprehensive guide for the SFA Sanibest Pro macerator pump, covering installation, operation, maintenance, and troubleshooting. Includes multilingual instructions and safety information.