JOINON WALLBOX I-CON DLM
Quick Installation Guide
Product Overview
The JOINON WALLBOX I-CON DLM is an electric vehicle charging station designed for wall mounting.
Visual Description: A compact, modern wall-mounted unit with an integrated charging cable and connector.
Installation Procedure
Step 1: Initial Setup
Unpack the wallbox. Familiarize yourself with the contents using the provided manual. A QR code is available for accessing digital documentation.
Visual Description: A person holding the wallbox unit and a printed manual, gesturing towards a QR code.
Step 2: Wall Marking
Select a suitable location on the wall for installation. Mark the mounting points accurately.
Visual Description: A person using a marker to draw alignment marks on a wall surface.
Step 3: Mounting Bracket Installation
Securely attach the wall mounting bracket to the wall using appropriate screws and wall anchors.
Visual Description: A close-up of screws and wall plugs, indicating their use for mounting.
Step 4: Wallbox Attachment
Mount the main wallbox unit onto the previously installed bracket.
Visual Description: The wallbox unit being positioned and attached to the wall bracket.
Step 5: Electrical Wiring
Open the wallbox enclosure to access the internal terminal block. Connect the incoming power supply cables: Line 1 (L1), Neutral (N), and Protective Earth (PE) for single-phase, or Line 1 (L1), Line 2 (L2), Line 3 (L3), Neutral (N), and Protective Earth (PE) for three-phase systems. Ensure all connections are made according to the wiring diagrams and local electrical regulations.
Visual Description: The wallbox is shown open, revealing internal electrical components and a terminal block. Two wiring diagrams are presented: one for single-phase (L1, N, PE) and one for three-phase (L1, L2, L3, N, PE) connections.
Important Safety Note: ⚠️ Always ensure the power supply is disconnected before performing any electrical connections.
Step 6: Final Enclosure
Close and secure the wallbox enclosure after completing the wiring.
Visual Description: The wallbox unit being closed, completing the installation.
Wiring Configurations
The JOINON WALLBOX I-CON DLM supports the following electrical supply configurations:
- Single-phase: Connect to L1, N, and PE terminals.
- Three-phase: Connect to L1, L2, L3, N, and PE terminals.
Visual Description: Detailed schematic diagrams illustrating the correct terminal connections for both single-phase and three-phase power inputs.