JOINON WALLBOX I-CON Power Supply Connection
Brand: GEWISS
Overview
This guide details the power supply connection for the GEWISS JOINON WALLBOX I-CON electric vehicle charging station. It covers the wiring for both 2-phase plus earth (2P+÷) and 3-phase plus neutral plus earth (3P+N+÷) configurations.
Terminal Blocks
The wallbox features two primary terminal blocks for power connections:
- Terminal Block 1: Designated for the electronic board's power supply.
- Terminal Block 2: Designated for the main power supply input.
Electronic Board Power Options
The electronic board within the wallbox can receive power through two distinct methods:
- Dedicated Line: Power can be supplied via a specific, dedicated line. This option is beneficial for enabling a potential power supply from an Uninterruptible Power Supply (UPS), ensuring continuity.
- Main Supply Tap: Alternatively, power can be drawn directly from the main power supply by connecting to the Line 1 (L1) and Neutral (N) terminals.
Diagrammatic Representation
The accompanying diagrams visually illustrate the physical layout of the terminal blocks and the routing of power cables (L1, N, PE for 2-phase; L1, L2, L3, N, PE for 3-phase) for each configuration. They show how the main power input is distributed to both the main supply terminal block and, via the specified methods, to the electronic board terminal block.
Contact Information
GEWISS S.p.A. provides contact details in accordance with relevant European Directives and Regulations:
Company: GEWISS S.p.A.
Address: Via A.Volta, 1, IT-24069 Cenate Sotto (BG), Italy
General Inquiries: +39 035 946 111
SAT Support: sat@gewiss.com
Quality Marks: qualitymarks@gewiss.com
Website: www.gewiss.com
Support Hours: Monday - Friday, 8:30 - 12:30 and 14:00 - 18:00.
Document Revision: 04/2021