Brayer BR4701 Ultrasonic Humidifier
Instruction Manual
Introduction
This document provides instructions for the Brayer BR4701 Ultrasonic Humidifier. It covers operation, safety, maintenance, and troubleshooting. Please read this manual carefully before using the unit and keep it for future reference. The document is available in multiple languages including English, German, Russian, Kazakh, and Belarusian.
Product Description
The BR4701 is an ultrasonic humidifier designed to increase the relative humidity in a room. It uses high-frequency vibrations to break water into fine particles (1-5 microns), creating a cool mist that mixes with the air. A comfortable room humidity level is between 40% and 60%. Insufficient humidity, especially during heating seasons, can negatively affect human health, pets, plants, and furniture.
Key Components:
- [Diagram 1: Humidifier Parts] The ultrasonic humidifier is depicted with its components clearly labeled. Key parts include: 1. Water tank, 2. Water inlet, 3. Filter, 4. Water tank lid, 5. Process chamber with sprayer, 6. Body, 7. Aromatic oil container, 8. Illumination on/off button, 9. On/off/mist release control knob, 10. Operation/no water indicator, 11. Water level scale, and 12. Lid with mist release nozzle.
- [Diagrams 2-6] Illustrations show the steps for assembling or disassembling the humidifier parts.
Technical Specifications
- Power supply: 220-240 V, ~50-60 Hz
- Rated input power: 25 W
- Water tank capacity: 3.0 L
- Water discharge: ≥ 250 ml/h
- Humidified area: up to 25 sq.m.
- Filter capacity: 3000 L
- Unit operating life: 3 years
Safety Measures and Operation Recommendations
Read the operation manual carefully before using the unit; after reading, keep it for future reference.
- Use the unit for its intended purpose only, as specified in this manual.
- Mishandling the unit can lead to its breakage and cause harm to the user or damage to the user's property, which is not covered by warranty.
- Ensure the operating voltage of the unit corresponds to your home mains voltage.
- Place and use the Ultrasonic humidifier on a flat, dry, and water-resistant surface. Maintain a distance of at least 30 cm from walls, furniture, and interior objects.
- Do not place the humidifier near computers or other sensitive electronic appliances.
- Do not place the unit on high-pile carpets.
- Do not use the Ultrasonic humidifier outdoors.
- It is not recommended to use the unit during lightning storms.
- Protect the unit from impacts, falling, vibrations, and other mechanical stress.
- Never leave the unit connected to the mains unattended.
- Do not use the unit near heating appliances, heat sources, or open flame.
- Do not use the unit in areas where aerosols are used or sprayed, or near inflammable liquids.
- Do not use the unit near kitchen sinks, in bathrooms, near swimming pools, or other containers filled with water.
- If the unit falls into water, unplug it immediately before removing it from the water.
- Do not let the power cord touch hot surfaces or sharp furniture edges.
- Unplug the unit after usage or before cleaning. When unplugging, hold the power plug, not the cord, to avoid damage and short circuits.
- Do not touch the unit body, power cord, or plug with wet hands.
- Use only supplied removable parts.
- Use tap water cleaned with domestic water filters, distilled, or boiled water. Water temperature should not exceed +40°C.
- Do not use sparkling or dirty water. Do not add perfume additives to the water tank.
- Do not switch the unit on without the water tank or if the tank is empty.
- Switch the humidifier off when the water tank is empty.
- Unplug the unit before removing the water tank.
- Do not cover the humidifier during operation.
- Do not cover air inlets or allow foreign objects to enter them.
- Do not immerse the humidifier, power cord, or plug in water or other liquids.
- Do not move or tilt the unit during operation, or remove the water tank.
- Switch off and unplug the unit before cleaning or when not in use. Empty the tank and process chamber.
- Unplug the unit before moving it. Carry the unit carefully by the body with both hands.
- Clean the unit regularly.
- For child safety, keep packaging materials (like polyethylene bags) out of reach and sight of children.
ATTENTION! ⚠️ Do not allow children to play with packaging film. Danger of suffocation! The unit is not intended for use by children. Supervise children to prevent them from using the unit as a toy. Do not allow children to touch the operating surface, unit body, power cord, or power plug during operation.
Close supervision is necessary when children or disabled persons are near the operating unit. During operation and breaks, place the unit out of children's reach.
This unit is not intended for use by persons with physical, mental, or sensory impairments (including children) or those lacking experience or knowledge, unless supervised or instructed by a responsible person.
Regularly check the power cord for damage. If damaged, it must be replaced by the manufacturer, service center, or qualified personnel to avoid danger.
Do not attempt to repair the unit yourself. Do not disassemble it. If a malfunction occurs or the unit is dropped, unplug it and contact a service center.
Transport the unit in its original packaging to avoid damage.
Store the unit in a dry, cool place out of reach of children and disabled persons.
THE UNIT IS INTENDED FOR HOUSEHOLD USAGE ONLY
Before the First Use
- After transportation or storage at negative temperatures, unpack the unit and wait for 3 hours before use.
- Use the humidifier at room temperatures between +10°C and +40°C, with relative humidity less than 80%.
- Unpack the unit and remove all packaging materials.
- Keep the original package.
- Check the delivery set.
- Read the safety measures and operating recommendations.
- Examine the unit for damages; do not plug it in if damaged.
- Ensure the power supply voltage matches your mains voltage.
Using the Ultrasonic Humidifier
- Remove the water tank (1) from the unit body (6) and remove the lid with the "mist" release opening (12) (Pic. 1).
- Turn the water tank (1) upside down, turn the lid (4) counterclockwise, and remove it (Pic. 2).
- Before first use, it is recommended to remove the filter (3) by turning it counterclockwise and immerse it in water for 5-10 minutes.
- Install the filter (3) onto the lid (4) and screw it clockwise.
- Fill the water tank (1) with the required amount of water (Pic. 3). Note: If using hard tap water, use water filtered by household filters or mix tap water with distilled water in a 1:1 ratio.
- Install the lid (4) onto the water inlet (2) and screw it clockwise.
- Place the filled water tank (1) onto the unit body (6).
- Wait for the process chamber (5) to fill with water.
- To use the aromatization function, remove the container (7). Add a few drops of water-soluble aromatic oil and reinstall the container (7) (Pic. 4). Notes: Use only water-soluble aromatic oils. If not using the function, remove, wash, dry, and reinstall the container.
- Insert the power plug into the socket.
- Switch on the humidifier by turning the knob (9) clockwise. The indicator (10) will turn green.
- Adjust the mist release intensity by turning the knob (9).
- Press the button (8) to turn the illumination on or off.
- If the water tank (1) is empty, the indicator (10) will turn red.
- Switch off the humidifier by turning the knob (9) counterclockwise and unplug the unit.
- Fill the tank (1) with water, install it, and switch the unit on.
- After operation, switch off the humidifier by turning the knob (9) counterclockwise and unplug the unit.
Cleaning and Maintenance
WARNING! ⚠️ Always switch off and unplug the humidifier before cleaning or maintenance.
Hard water can cause mineral scale buildup in the process chamber (5), on the sprayer, and in the water tank (1), leading to reduced efficiency.
- It is recommended to clean the process chamber (5) and sprayer weekly, and change the water in the tank (1).
- If the humidifier will not be used for an extended period:
- Empty water from the tank (1) and process chamber (5).
- Wash and clean the process chamber (5) and sprayer.
- Wash the water tank (1).
- Dry the unit thoroughly and store it.
Weekly Care
- Once a week, wash the water tank (1), process chamber (5), and sprayer with warm water and a neutral detergent. Rinse thoroughly with water (Pic. 5).
- Add a few drops of detergent to the sprayer and wait a few minutes. Use a brush to remove deposits from the sprayer surface (Pic. 6). Note: Scale removal substances for electric kettles can be used for the process chamber (5) and sprayer, strictly following their instructions.
- Clean the unit body (6) with a slightly damp cloth and then dry it.
- Do not immerse the unit body (6), power cord, or plug in water or other liquids. Ensure no liquid enters the unit body (6).
- Do not use solvents or abrasive cleaners on the body (6) or water tank (1).
Storage
- Before storing, clean the humidifier and ensure all parts are dry. Pack the unit in its original packaging.
- Do not store the unit with a wet filter (3), residual water in the tank (1), or process chamber (5).
- Store the humidifier in a dry, cool place out of reach of children and disabled persons.
Troubleshooting
Problem | Possible Causes | Troubleshooting |
---|---|---|
Indicator doesn't light up, no mist release | No supply voltage or the mains socket is damaged. | Connect the unit to the mains. Plug another, known good appliance into the socket to verify it works properly. |
Indicator is glowing red, no mist release. | The water tank is empty. | Fill the water tank with water. |
Released mist has foreign smell. | First use of the unit. | Drain water from the tank and leave it open for several hours in a cool place. |
Stale water in the tank. | Unplug the unit, remove the water tank, pour out the water, wash the tank, and fill with clean water. | |
Low mist release intensity | Mineral scale on the sprayer. | Unplug the unit and clean the sprayer. |
Delivery Set
- Ultrasonic humidifier assembled — 1 pc.
- Manual — 1 pc.
Recycling and Disposal
To prevent environmental harm or health risks from uncontrolled waste disposal, do not discard the unit or batteries with household waste after their service life. Take them to specialized recycling stations.
Waste generated during disposal must be collected and disposed of properly.
For more information on recycling, contact your local municipal administration, waste disposal service, or the retailer where you purchased the product.
The manufacturer reserves the right to change the appearance, design, and specifications without prior notice, provided these changes do not affect the general operating principles of the unit.
Manufacturer Information
Manufactured for: Ruste GmbH, Berggasse 18/18, 1090 Vienna, Austria.
Produced for: Ruste GmbH, Berggasse 18/18, 1090 Vienna, Austria.
Manufactured by order of Ruste GmbH, Berggasse 18/18, 1090 Vienna, Austria.
Authorized manufacturer representative: OOO "Grantel", 143912, Moscow region, Balashikha, Enthusiasts highway, building 1A.
Tel: +7 (495) 297-50-20, e-mail: info@brayer.su
Made in China.