BRAYER BR4930 Air Purifier
Introduction
The BRAYER BR4930 is an appliance designed for cleaning indoor air from dust, pet hair, tobacco smoke, allergens, bacteria, and unpleasant odors.
Description
Main Components:
- 1. Filter lid: The cover for the filter compartment.
- 2. Filter: The primary filter unit for air purification.
- 3. Air inlet grid: Where air is drawn into the purifier.
- 4. Control panel: Touch-sensitive buttons for operation.
- 5. Body: The main housing of the air purifier.
- 6. Fragrance basket: For adding aromatic oils.
- 7. Air outlet grid: Where purified air is expelled.
Control Panel (4) Buttons:
- 8. On/off/operation mode selection button: [Power/Mode] Used to turn the unit on/off and cycle through operation modes.
- 9. Low speed indicator: [Speed 1] Lights up when the purifier is on low speed.
- 10. Medium speed indicator: Lights up when the purifier is on medium speed.
- 11. Maximal speed indicator: [Speed 3] Lights up when the purifier is on maximum speed.
- 12. Ionization on/off button: [Ionizer] Activates or deactivates the ionizer function.
- 13. Filter use reset button: [Filter Reset] Used to reset the filter life indicator.
Diagram Description: The air purifier is a cylindrical unit with a top air outlet grid and a base. The control panel is located on the top surface. Various components are numbered for identification.
Diagram Description: The diagrams illustrate the filter installation process: Pic. 1 shows how to remove the filter lid. Pic. 2 shows how to remove the filter from the unit. Pic. 3 shows unpacking the new filter. Pic. 4 shows inserting the filter into the unit. Pic. 5 shows how to reattach and secure the filter lid. Pic. 6 shows the fragrance basket for adding aromatic oils.
Air Purifier Features
The air purifier utilizes filters and an air ionizer to clean indoor air.
Prefilter:
The filtering mesh retains dust particles larger than 0.2 mm. It is easy to clean and reusable.
HEPA filter and Coal filter:
- The HEPA filter cleans air from dust particles smaller than 2.5 microns, trapping plant pollen, viruses, and bacteria.
- Activated carbon absorbs unpleasant odors and tobacco smoke, trapping allergens, plant pollen, and animal hair.
Air Ionizer:
The ionizer saturates the air with negatively charged ions, beneficial for the well-being of people, animals, and plants, creating a clean, fresh atmosphere.
ATTENTION! The air purifier does not retain gases like carbon monoxide (CO) or radon (Rn) and cannot be used for air purification during fires or chemical releases.
Safety Measures and Operation Recommendations
Read the operation instructions carefully before use and keep them for future reference.
- Use the unit only for its intended purpose as described in this manual.
- Mishandling can lead to breakage, harm to the user, or damage to property, which is not covered by warranty.
- Ensure the unit's operating voltage matches your home mains voltage.
- Place and use the air purifier on a flat, dry, and steady surface. Maintain a distance of at least 20 cm from walls and furniture, and 30-50 cm clearance above the unit.
- Do not use the air purifier outdoors.
- It is not recommended to use the unit during lightning storms.
- Protect the unit from impacts, falls, vibrations, and other mechanical stress.
- Never leave the unit connected to the mains unattended.
- Do not use the unit near heating appliances, heat sources, or open flames.
- Do not use the unit where aerosols are used or sprayed, or near flammable liquids.
- Do not immerse the air purifier, power cord, or plug in water or other liquids.
- Do not use the unit near sinks, bathrooms, swimming pools, or other water-filled containers.
- If the unit falls into water, immediately unplug it before removing it from the water.
- Ensure the power cord does not touch hot surfaces or sharp furniture edges.
- Unplug the unit after use or before cleaning. When unplugging, hold the plug firmly and pull it out of the socket; do not pull the cord, as this can cause damage or a short circuit.
- Do not touch the unit body, power cord, or plug with wet hands.
- Use only supplied removable parts.
- Do not cover the air purifier during operation.
- Do not block air inlets or allow foreign objects to enter them.
- Clean the unit regularly.
- For child safety, do not leave packaging polyethylene bags unattended.
- Attention! Do not allow children to play with polyethylene bags or packaging film. Danger of suffocation!
- The unit is not intended for use by children. Supervise children to prevent them from using the unit as a toy.
- Do not allow children to touch the operating surface, unit body, power cord, or plug during operation.
- Exercise extra caution if children or disabled persons are near the operating unit.
- During operation and breaks, place the unit out of children's reach.
- The unit is not intended for use by persons with reduced physical, sensory, psychic, or mental capabilities (including children) or those lacking experience or knowledge, unless supervised or instructed by a person responsible for their safety.
- Periodically check the power cord for integrity. If damaged, it must be replaced by the manufacturer, service center, or qualified personnel.
- Do not attempt self-repair. Do not disassemble the unit. If a malfunction occurs or after dropping, unplug and contact a service center.
- Transport the unit in its original packaging to avoid damage.
Before First Use
After transportation or storage at negative temperatures, unpack the unit and wait for 3 hours before use.
- Unpack the unit and remove all packaging materials.
- Keep the original packaging.
- Read safety measures and operating recommendations.
- Check the delivery set.
- Examine the unit for damage; do not plug it in if damaged.
- Ensure the unit's power supply voltage specifications match your mains voltage. A 60 Hz mains supply does not require additional settings.
Preparing the Filters
ATTENTION! Before removing the lid (1), ensure the power plug is not inserted into the socket.
- Place the air purifier horizontally.
- Remove the lid (1) by turning it to the position [Unlock symbol] (Pic. 1).
- Remove the filter (2) from the air purifier body (5) (Pic. 2).
- Unpack the filters (Pic. 3).
- Install the filter (2) into the air purifier body (5) (Pic. 4).
- Reinstall the lid (1) and turn it to the position [Lock symbol] (Pic. 5).
- The air purifier is now ready for operation.
Using the Air Purifier
Place and use the air purifier on a flat, dry, and steady surface. Maintain a distance of at least 20 cm from walls and furniture, and 30-50 cm clearance above the unit.
Switching On:
The control panel (4) buttons are touch-sensitive. Each touch is accompanied by a sound signal.
- Connect the power plug to the mains socket. A sound signal indicates the purifier is in standby mode.
- To turn on the purifier, touch the on/off/operation mode selection button (8) [Power/Mode]. The purifier will start at low speed, and the indicator (9) will light up.
- To turn off the purifier, touch and hold the on/off/operation mode selection button (8) [Power/Mode] for 3-5 seconds. The purifier will switch to standby mode. Then unplug the unit.
- To change speed modes, touch the on/off/operation mode selection button (8) [Power/Mode]. Speed modes are indicated by indicators (9, 10, 11).
- Maximum speed is indicated by indicator (11) [Max Speed].
Ionization Mode:
- To activate ionization, touch button (12) [Ionizer].
- To deactivate ionization, touch button (12) [Ionizer] again.
Fragrance Basket:
Remove the aromatic oil container (Pic. 6), add a few drops of aromatic oil, and reinstall the container.
Resetting Filter Operation Time:
If indicator (13) [Filter Reset] lights up and flashes during operation, the filter (2) needs cleaning or replacement.
ATTENTION! Before removing the lid (1), ensure the power plug is not inserted into the mains socket.
- Remove the lid (1) by turning it to the position [Unlock symbol] (Pic. 1).
- Remove the filter (2) from the air purifier body (5) (Pic. 2).
- Using a vacuum cleaner with an appropriate attachment, clean the outer surface of the filter (2).
- Install the filter (2) into the air purifier body (5) (Pic. 3).
- Reinstall the lid (1) and turn it to the position [Lock symbol] (Pic. 5).
- Turn on the air purifier by touching the on/off/operation mode selection button (8) [Power/Mode].
- Touch and hold button (13) [Filter Reset] for 3-5 seconds. A sound signal will be heard, and the indicator [Filter Reset] will turn off.
Cleaning and Maintenance
- Before cleaning, switch off the air purifier and ensure the power plug is disconnected from the socket.
- Wipe the unit body (5) with a slightly damp cloth, then dry it.
- Do not use liquid detergents, abrasive cleaners, or solvents.
- To prevent electric shock, ensure no water or other liquids enter the air purifier body.
- Clean air grids (3, 7) using a vacuum cleaner with an appropriate attachment.
- To extend filter life, periodically remove and clean filters (2) from dust and lint.
Storage
- After cleaning, store the air purifier in a dry, cool place inaccessible to children and disabled persons.
- Before next use, check the unit's operability, power cord insulation, and plug integrity.
Delivery Set
- Air purifier with installed filters - 1 pc.
- Instruction manual - 1 pc.
Technical Specifications
- Power supply: 220-240 V ~ 50 Hz
- Rated input power: 25 W
- Negative ion output: ≥ 10.0 million/cm³ (10 cm from the air outlet grid)
- Room area: up to 18 m²
- Productivity: 150 m³/hour
Recycling
To prevent environmental damage or harm to health from uncontrolled waste disposal, do not discard the unit or batteries with household waste after their service life. Take them to specialized collection points for recycling.
Waste generated during product disposal must be collected and disposed of properly.
For more information on recycling, contact your local municipal administration, waste disposal service, or the shop where you purchased the product.
Manufacturer's Information
The manufacturer reserves the right to change the design, construction, and technical specifications that do not affect the general operating principles of the unit, without prior notice.
Unit operating life: 3 years
Manufacturing date is specified in the serial number.
For malfunctions, contact an authorized service center promptly.