Distributed by HoMedics
Cool & Warm Mist Dual Tank Ultrasonic Humidifier
Model: UHE-WM65
Instruction Manual and Warranty Information
1 year limited warranty
Register Your Product At: www.homedics.com/register
Important Safety Instructions
When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:
Read All Instructions Before Using
DANGER - To Reduce the Risk of Electric Shock:
- Always place humidifier on a firm, flat surface. A waterproof mat or pad is recommended for use under the humidifier. Never place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.
- Always unplug the unit from the electrical outlet immediately after using and before cleaning.
- DO NOT reach for a unit that has fallen into water. Unplug it immediately.
- DO NOT use while bathing or in the shower.
- DO NOT place or store the unit where it can fall or be pulled into a tub or sink.
- DO NOT place or drop into water or other liquids.
- DO NOT use water above 86° Fahrenheit (30° C).
WARNING - To Reduce the Risk of Burns, Electric Shock, Fire or Injury to Persons:
- A unit should never be left unattended while plugged in.
- Close supervision is necessary when this unit is used by or near children, invalids, or disabled persons.
- Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by HoMedics; specifically any attachments not provided with this unit.
- NEVER drop or insert any object into any opening.
- DO NOT operate where aerosol (spray) products are being used, or where oxygen is being administered.
- Always hold the water tank firmly with both hands when carrying a full tank of water.
- NEVER use the humidifier in an environment where explosive gasses are present.
- DO NOT place the humidifier near heat sources, such as a stove, and do not expose the humidifier to direct sunlight.
- DO NOT carry this unit by the power cord or use the power cord as a handle.
- To disconnect, turn all controls to the “off” position, then remove the plug from the outlet.
- This unit is designed for personal, non-professional use only.
- DO NOT use outdoors. For indoor use only.
SAVE THESE INSTRUCTIONS
CAUTION - Please Read All Instructions Carefully Before Operation.
- Never cover the unit while it is operating.
- Always keep the cord away from high temperature and fire.
- If the cord sustains damage, you must stop using this product immediately and contact HoMedics consumer relations (see Warranty section for consumer relations contact information).
- Perform regular maintenance on the ultrasonic membrane.
- Never use detergent to clean the ultrasonic membrane.
- Never clean the ultrasonic membrane by scraping with a hard object.
- Do not attempt to adjust or repair the unit. Servicing must be performed by professional or qualified personnel.
- Stop using this unit if there is an unusual noise or smell.
- Unplug this unit when not in use for a long period of time.
- Do not touch the water or any parts of the unit that are covered by water while the unit is on or plugged in.
- Never operate without water in the tank.
- Only use water in the tank.
- Never use any additive to the water.
- Do not wash, adjust, or move this unit without first unplugging it from the electrical outlet.
- Keep this unit out of reach of children. Do not allow children to use this unit without supervision.
Unique Features and Specifications
Unique Features
Ultrasonic Technology
This humidifier uses ultrasonic high frequency technology to convert the water into 1–5 million super particles that are dispersed into the air evenly.
Warm & Cool Mist Function
Choose either warm or cool mist for customized comfort.
Night Light
A useful night light feature is included for your convenience.
Auto Shut-Off Protection
When the tank is empty the unit will shut off automatically.
Specifications
Feature | Value |
---|---|
Voltage | 120V/60Hz |
Watts | 101 |
Capacity | 1.7 gallon – 6.11 liters |
Run Time | 72 hours |
Run time is calculated based on using cool water and setting the mist level between the low and medium settings. Based on the natural humidity level in your home, the temperature of water you use, and the mist level setting you choose, you may experience longer or shorter run times.
How to Use
Control Panel Description: The unit features a Power ON/OFF button, a Warm Mist button, a Night Light ON/OFF button, and a Mist Increase/Decrease Adjustment Knob. The Night Light illuminates a ring around the knob.
Power ON/OFF Button
Plug the unit into a 120-volt AC electrical outlet. Press the POWER ON/OFF button to turn the unit on. Press the POWER ON/OFF button again to turn the unit off.
ATTENTION: When the water in the tank is almost empty, the humidifying function will power off to indicate to the user to refill the tank.
Mist Adjustment Setting
Mist adjusts from lowest output to highest output. To increase the mist output, turn the MIST adjustment knob clockwise. To decrease mist output, turn the MIST adjustment knob counter-clockwise.
Mist Temperature Setting
When the humidifier is powered ON, it will be operating on the default setting—Cool Mist. To change the Mist Temperature from Cool Mist to Warm Mist, press the WARM MIST button. The mist temperature will change to Warm Mist, and the WARM MIST button will be illuminated red. To change the Mist Temperature back to Cool Mist, press the WARM MIST button again. The mist temperature will change to Cool Mist, and the light in the WARM MIST button will turn off.
NOTE: Once warm mist is selected, it will take 20 minutes before the mist becomes warm.
Night Light
Press the NIGHT LIGHT button to turn on the night light. The surround around the POWER/MIST knob will glow softly.
How to Fill
CAUTION: Before filling the unit with water, turn the power off and unplug the unit from the outlet.
NOTE: Always use two hands to carry the water tank.
- Grasp the tank handle with both hands and lift it up from the humidifier base. Remove only one tank at a time.
- Turn the tank upside down and remove the tank cap by turning it counter-clockwise.
- Fill the water tank with clean, cool water (not cold). It is recommended to use distilled water if you live in a hard water area.
- Replace the tank cap by turning clockwise until tight.
- Install both tanks back on the base of the unit. Make sure the tanks are firmly seated.
NOTE: This unit uses water from one tank at a time. It will use all the water from one tank before beginning to pull water from the other tank.
NOTE: It is normal to have a small amount of water in the base during and after use.
About White Dust
The use of high mineral content hard water may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. This mineral residue is commonly called “white dust.” The higher the mineral content (or, the harder your water is), the greater the potential for white dust. The white dust is not caused by a defect in the humidifier; it is caused only by minerals suspended in the water.
How and Why To Use Demineralization Cartridges
The HoMedics demineralization cartridge helps reduce the potential for white dust, a deposit of minerals left behind from using hard water in your humidifier. The cartridge should be replaced every 30–40 fillings. The cartridge may need to be replaced more often if you are using very hard water. Replace the cartridge when you notice an increase in white dust build-up. If white dust still forms around the humidifier after a new cartridge has been installed, consider using distilled water.
To purchase new demineralization cartridges, model # UHE-HDC4, visit your retailer or www.homedics.com.
If you live in an area with hard water, or use a water softener, it is recommended to use distilled water for better results from your humidifier. Never use water softening additives in your humidifier.
Installation Instructions (Demineralization Cartridge)
- Remove the demineralization cartridge from packaging and let it soak in water for 10 minutes.
- Remove the tank from the humidifier base and turn it over.
- Unscrew the tank cap by turning the cap counter-clockwise.
- Fill the tank with water as shown in the “How to Fill” section of the instructions.
- Add the soaked demineralization cartridge into the tank.
- Replace the tank cap by turning clockwise.
- Place the tank back on the base.
Cleaning and Care
CAUTION: Before cleaning the unit, turn the power off and unplug the unit from the outlet.
To Clean the Tank
Remove the tank from the humidifier base by lifting it from the main unit. Unscrew the tank cap and rinse the inside of the tank with clean water. To remove any scale or build-up, use a 50/50 mixture of vinegar and lukewarm water to clean the inside of the tank. It is suggested to clean the water tank once every two to three weeks, depending on your water conditions.
To Clean the Ultrasonic Membrane
Pour a 50/50 mixture of vinegar and water onto the surface of the ultrasonic membrane, then soak for five minutes. Brush clean with a soft-bristle brush and rinse. NEVER touch the ultrasonic membrane with your fingers, as the natural oils in skin can damage the membrane. It is suggested to clean the membrane once every two to three weeks, depending on your water conditions.
NOTE: Never submerge the base in water or any liquid.
To Clean the Surface
Clean the surface of your humidifier with a clean, damp, soft cloth as often as needed.
Troubleshooting
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
No Power/ No Mist from Spout | • Unit is not plugged in • No power at unit • Low water level |
• Plug unit in. • Turn the Power/Mist knob clockwise to turn the power on. • Check circuits and fuses or try a different outlet. • Refill the tank with water. |
Peculiar Odor | • Unit is new • If unit is in use, the odor may be a dirty tank or old tank water |
• Open the water tank cap and keep it in a shady, cool place for 12 hours. • Empty the old water, clean the tank, and fill with clean water. |
Excessive Noise | • Unit is not level • Low water level |
• Place unit on a flat, even surface. • Check the water level. Refill the tank if the water is low. |
White Dust Accumulation | • Hard water used • Demineralization Cartridge needs replacement |
• Use distilled water and a Demineralization Cartridge. • Replace Demineralization Cartridge. |