Warning
In case of TPU tubes with Presta valves, connect them using an extension air hose (available separately), otherwise the valves may melt due to overheating.
A warning graphic shows a red cross (❌) indicating an incorrect connection and a green checkmark (✔️) indicating a correct connection. The correct connection uses a hose labeled "Hose" and "Available separately" attached to a valve labeled "Presta". The incorrect connection implies direct attachment without the hose.
Package Contents
- Pump
- Silicone Case
- Sealing Part
- Adapter/Nozzle
- Cable
- Waterproof Bag
Details and Specifications
Type-C Charging Port
Nozzle
Power Button & Indicator
Size: 65*46.5*28 mm
Battery: 7.4 V * 300 mAh
Current: 2.5~5.5 A
Charging Mode: Type-C 5V 1.5A
Weight: 97 g
Working Time: approx. 200 s
Maximum Pressure: 100 PSI
Air Nozzle Adaptation
The pump is ready to use with Presta valves immediately after unpacking. For Schrader valves, reassemble the nozzle as shown below.
Two nozzle configurations are shown:
- For Presta valve: Nozzle Cap, Sealing Part, Small hole outwards.
- For Schrader valve: Nozzle Cap, Sealing Part, Large hole outwards, Adapter for Schrader valve.
Operation
- Press the power button to activate the pump, and the indicator will light up. The color indicates charge level: Green: 80%~100%, Yellow: 50%~80%, Red: <50%.
- Press the power button twice within 3 seconds of activation to start pumping.
- Attach the pump to the valve stem and hold firmly.
- Press the power button again to stop pumping and turn off the pump.
- Remove the pump.
Note: Do not approach the charging port during operation.
Instruction: Always loosen the nut first (referring to the valve stem).
Diagram Description: Shows "Air In" and an upward arrow indicating air intake into the valve.
Notes
- Fully charge the pump before use.
- The pump may get hot during operation; use the silicone case.
- Press the pump firmly against the valve before and during inflation, then adjust its position to prevent air leaks.
- It is normal to feel some resistance when removing the pump from a Presta valve after inflation.
Charging
Charge the device using a suitable charger. A full charge takes about 25 minutes. The indicator will flash red during charging and turn green when fully charged. After one full charge, the device can pump for approximately 200 seconds.
Diagram Description: Shows a charging indicator light.
Working performance after full charge:
Tire Type | Pressure | Inflation Time | Available Time (seconds) |
---|---|---|---|
700C25 | 0-60PSI | 50~60 sec | 4 |
700C25 | 0-80PSI | 80~90 sec | 2 |
700C25 | 0-100PSI | 150~160 sec | 1 |
26x1.95 | 0-35PSI | 70~80 sec | 2 |
26x1.95 | 0-50PSI | 120~130 sec | 1 |
Experimental data is for reference only.
Manufacturer
Chengdu Chendian Intelligent Technology Co., Ltd
Unit 2, Building 2, No. 88, Tianchen Road, Chengdu, Sichuan, CN, Postal Code: 611730
Environmental Protection
Electronic waste marked according to the European Union directive must not be disposed of with other municipal waste. It is subject to selective collection and recycling at designated points. By ensuring its proper disposal, you prevent potential negative consequences for the natural environment and human health. The system for collecting used equipment complies with local environmental regulations regarding waste disposal. Detailed information on this matter can be obtained from the municipal office, waste disposal facility, or the store where the product was purchased.
The product meets the requirements of the EU's New Approach Directives concerning safety, health, and environmental protection, defining hazards that should be detected and eliminated.
This document is a translation of the original user manual created by the manufacturer.
Detailed information on distributor/manufacturer warranty conditions is available at https://serwis.innpro.pl/gwarancja
The product should be regularly maintained (cleaned) by the user or by specialized service points at the user's cost and expense. In the absence of information on necessary cyclical or service maintenance actions in the user manual, regularly, at least once a week, assess any deviation of the product's physical condition from that of a new product. In case of detecting or identifying any deviation, promptly take maintenance (cleaning) or service steps. Failure to properly maintain (clean) and react promptly upon detecting a deviation may lead to permanent damage to the product. The guarantor is not responsible for damages resulting from negligence.
Importer
INNPRO Robert Błędowski sp. z o.o.
ul. Rudzka 65c
44-200 Rybnik, Poland
Tel: +48 533 234 303
Email: hurt@innpro.pl
Website: www.innpro.pl
Safety Precautions
Before charging, check if the device contacts are clean. Never leave the device unattended during use and charging. Ensure you can quickly disconnect the device from the power source in an emergency. Never expose the device to high temperatures. Charge the device in a dry and well-ventilated area, away from flammable materials, maintaining a clear space of at least 1 meter from other objects. Never cover the device during charging. Never use a power adapter, charging station, cables, etc., without the manufacturer's recommendation and certification. Protect your property; the device is equipped with cells that are difficult to extinguish. Equip yourself with a fire blanket.
LI-ION Battery
The device is equipped with a LI-ION (lithium-ion) battery, which ages over time and with use due to its physical and chemical structure. The manufacturer specifies the maximum working time of the device under laboratory conditions, where optimal operating conditions exist and the battery is new and fully charged. Actual working time may differ from the declared time and is not a defect but a characteristic of the product. To maintain maximum battery life, it is not recommended to discharge it below 3.18V or 15% of its total capacity. Lower values, such as 2.5V for a cell, will permanently damage it and are not covered by warranty. If the battery or the entire device is not used for more than one month, charge the battery to 50% and check its charge level cyclically every two months. Store the battery and device in a dry place, away from sunlight and freezing temperatures.
LI-PO Battery
The device is equipped with a LI-PO (lithium-polymer) battery, which ages over time and with use due to its physical and chemical structure. The manufacturer specifies the maximum working time of the device under laboratory conditions, where optimal operating conditions exist and the battery is new and fully charged. Actual working time may differ from the declared time and is not a defect but a characteristic of the product. To maintain maximum battery life, it is not recommended to discharge it below 3.5V or 5% of its total capacity. Lower values, such as 3.2V for a cell, will permanently damage it and are not covered by warranty. If the battery or the entire device is not used for more than one month, charge the battery to 50% and check its charge level cyclically every two months. Store the battery and device in a dry place, away from sunlight and freezing temperatures.