Hormann Aluminium Fire Protection Element A / RS 350, Fixed Glazing
Main Functions
- Smoke protection according to DIN 18095
Optional Performance Characteristics
- Sound insulation up to 42 dB
- Fall protection A/C2
Product Description
Profile Material: Aluminium tube frame made of extruded profiles DIN 1725, single-skin.
Visible Width Leaf / Frame: 70 mm
Installation Depth: 50 mm
Base Height: 150 / 105 / 70 mm
Mullion Height: 100 mm
Filling: 6 mm laminated safety glass; optionally with panel or a combination of panel/glass.
Extension Profiles: 25 or 50 mm
Glass Retaining Strips: Optionally on the hinge side or opposite the hinge side.
Dimensions with Transom/Mullion (in mm)
Frame Outer Dimension | Width | Height |
---|---|---|
Frame Outer Dimension | 300 - unlimited | 300 - 4500 |
Maximum Door Height | 3000 mm |
Surfaces
- Standard: High-quality powder coating in RAL 9016 matt
- Anodized: Anodized surface E6 / EV1
- RAL by Choice: High-quality powder coating in RAL by choice (gloss levels: matt or matt fine structure (gloss level 30 ± 5), silk gloss (gloss level 75 ± 10); high gloss (gloss level > approx. 85, gloss points according to ISO 2813, 60-degree measuring angle) available on request).
Performance Characteristics
Characteristic | Achievable Values | Function |
---|---|---|
Smoke Protection | According to DIN 18095 | ● (Standard) |
Sound Insulation | Up to 42 dB | ○ (Optional) |
Fall Protection | A/C2 according to DIN 18008-4 | ○ (Optional) |
Note: The specified performance characteristics are only achieved with the corresponding equipment. The values depend on the door equipment and installation situation.
Permissible Walls and Minimum Wall Thicknesses
Permissible Walls | Minimum Wall Thicknesses (Frame Height) |
---|---|
Walls made of masonry according to DIN 1053-1, stone strength class ≥ 12, mortar group ≥ II | ≥ 115 |
Walls made of concrete according to DIN 1045-1, strength class ≥ C12/15 | ≥ 100 |
Walls made of aerated concrete, block or plain stone according to DIN 4165-3, strength class 4, at least F30 | ≥ 115 |
Walls made of reinforced aerated concrete slabs according to abZ, strength class 4.4, at least F30 | ≥ 115 |
Installation walls F90-A according to DIN 4102-4, Table 10.2 | ≥ 100 |
Installation walls F90-B according to DIN 4102-4, Table 10.3 | ≥ 50 |
Installation wall according to AbP | According to test certificate |
Cross-sections and Dimension References
RAM: Frame Outer Dimension
LDVB: Clear passage glazing width
LDVH: Clear passage glazing height
SPA: Mullion spacing
Post / Transom Construction
[Diagram showing post/transom construction]
Coupled Construction
[Diagram showing coupled construction]
Plug-in System
[Diagram showing plug-in system]
Wall Connections
Masonry / Concrete - Dowel Mounting: [Diagram showing masonry/concrete dowel mounting]
Masonry / Concrete - Weld Mounting: [Diagram showing masonry/concrete weld mounting]
Masonry / Concrete - Flush Wall Screw Mounting: [Diagram showing masonry/concrete flush wall screw mounting]
Lightweight Walls - Weld Mounting: [Diagram showing lightweight walls weld mounting]
Lightweight Walls - Flush Wall Screw Mounting: [Diagram showing lightweight walls flush wall screw mounting]
Lightweight Walls - Screw Mounting: [Diagram showing lightweight walls screw mounting]
The information provided, especially details and illustrations, is non-binding and does not constitute an agreement on quality or a guarantee. Subject to changes and errors. The datasheet is protected by copyright. Reprinting, including excerpts, only with our permission.