Hormann Aluminium Fire-Resistant Interior Door A / RS 200
Datenblatt (Datasheet)
Main Functions
- Rauchschutz nach DIN 18095 (Smoke protection according to DIN 18095)
- Schallschutz bis 40 dB (Sound insulation up to 40 dB)
- Einbruchschutz RC2 (Burglar resistance RC2)
Optional performance characteristics with appropriate equipment.
Product Description
Profile Material: Aluminium profiles, 2-ply with thermal insulation through quality-secured, shear-resistant composite made of polyamide 6.6, 25% glass fiber reinforced.
View Width Leaf / Frame: 150 mm
Installation Depth: 80 mm
Base Height: 105 / 150 mm
Mullion Height: 100 mm
Filling: ISO safety glass 24 mm, optionally with panel or combination of panel / glass.
Widening Profiles: 25, 50, 100, or 150 mm
Glass Retaining Strips: Optionally on hinge side or opposite hinge side
Security Bolts: ≤ Frame height 2620 mm 1 bolt, ≤ Frame height 3000 mm 2 bolts per leaf
Dimensions with Frame (in mm)
Frame Outer Dimensions | Width | Height |
---|---|---|
Frame Outer Dimensions | 1355 - 3000 | 1740 - 3000 |
Clear Passage (90° Opening) | 1067 - 2712 | 1670 - 2930 |
Clear Passage (180° Opening) | 1215 - 2860 | 1670 - 2930 |
Mullion Leaf Division | 750 - 1500 | |
Mullion Fixed Leaf Division | 500 - 1500 |
Standard Fittings
- Door Seal: Retractable floor seal
- Threshold: Thermally separated threshold
- Handle Set: Both-sided aluminum round handle D-116 cranked, with steel core including cylinder escutcheons
- Lock: Mortise lock PZ-perforated DIN 18250 Class 5
- Closing Device: Concealed door closer TS 5000 ISM with slide rail according to DIN EN 1154 with integrated closing sequence control
- Locking Mechanism: Rebate bolt and latch lock (top)
- Sealing System: Perimeter EPDM stop seal
- Hinges: 4 aluminum 3D hinges, 2-part, 3-dimensional adjustable
- Hinges: 4 aluminum 3D hinges, 3-part, 3-dimensional adjustable
- Hinges: Roller door hinge
For further fittings, please refer to our dealer price list Part C and the product configurator.
Surfaces
- Standard: High-quality powder coating in RAL 9016 matt, anodized surface E6 / EV1
- RAL on Request: High-quality powder coating in RAL of choice
- Gloss Levels: Matt or Matt Fine Structure (Gloss Level 30 ± 5), Silk Gloss (Gloss Level 75 ± 10)
- High Gloss: High gloss (Gloss Level > approx. 85, gloss points according to ISO 2813, 60-degree measuring angle) available on request
Performance Characteristics
Characteristic | Achieved Values | Function |
---|---|---|
Smoke Protection | according to DIN 18095 | ● (Standard - series) |
Sound Insulation | up to 40 dB | ○ (Additional function - optional with appropriate equipment) |
Burglar Resistance | RC2 | ○ (Additional function - optional with appropriate equipment) |
The specified performance characteristics are only achieved with the appropriate equipment. The values depend on the door equipment and installation situation.
Permissible Walls and Minimum Wall Thicknesses
Walls | Minimum Wall Thicknesses (Frame Height) |
---|---|
Masonry walls according to DIN 1053-1, stone strength class ≥ 12, mortar group ≥ II | ≥ 115 |
Concrete walls according to DIN 1045-1, strength class ≥ C12/15 | ≥ 100 |
Aerated concrete block or aerated concrete plan blocks according to DIN 4165, strength class 4 | ≥ 150 |
Reinforced - horizontal or vertical aerated concrete slabs with general building supervisory approval (abZ), strength class G.4 | ≥ 150 |
Installation walls F90-A according to DIN 4102-4, Table 10.2 | ≥ 100 |
Installation walls F90-B according to DIN 4102-4, Table 10.3 | ≥ 100 |
Installation wall according to AbP (General Building Approval) | according to test certificate |
For burglar-resistant doors | RC2 |
Masonry walls according to DIN 1053-1, stone strength class ≥ 12, mortar group ≥ II | ≥ 115 |
Concrete walls according to DIN 1045-1, strength class ≥ C12/15 | ≥ 120 |
Aerated concrete block or aerated concrete plan blocks according to DIN 4165, strength class 4 | ≥ 240 |
Cross-sections and Dimension References
Diagrams illustrating different construction types (Post / Transom Construction, Coupling Construction, Plug-in System) and wall connections (Masonry/Concrete with dowel mounting, screw mounting, flush screw mounting; Lightweight construction with screw mounting, flush screw mounting) are provided. These diagrams show detailed measurements and connection types.
Wall Connections
Detailed technical drawings illustrate various wall connection methods for the door, including dowel mounting, screw mounting, and flush screw mounting for both masonry/concrete and lightweight construction types. These drawings specify minimum distances and mounting details.