Owner's Manual for INSTEON models including: INSTEON, 2635-222, On/Off Module, Smart Home, Home Automation, Appliance Module, Controller, Responder, Linking, Programming

INSTEON On/Off Module 2635-222 Owner's Manual

INSTEON devices can stand alone and function as a local switch or dimmer, but their real power comes when they are connected together to form a control ...

PDF preview unavailable. Download the PDF instead.

2635-222
®
INSTEON On/Off Module 2635-222 Owner's Manual

Contents

Getting Started

INSTEON On/Off Module

4

Device Overview

Buttons

Installation

Leave Your Appliance On

INSTEON Links

Understanding Linking

6

Links are One-Way

Links Remember a Device's State

Controllers

Responders

Controller-Only

7

Responder-Only

Grouping Devices

Use Cross Linking

Linking to the INSTEON Hub

8

Linking with a Single-Button Controller

9

Linking with a Multi-Button Controller

10

Multi-Linking or Making a Scene

11

Unlinking from a Single-Button Controller

12

Unlinking from a Multi-Button Controller

13

Multi-Unlinking or Removing a Scene

14

Local Programming

About Local Programming

16

Local Programming

Navigation

Local Programming Features

Local Programming Flow Chart

17

Software-Only Features

Beep on Button Press

19

Disable Local Programming

Blink on Traffic

Error Blink

Appendix

Specifications

22

Troubleshooting

25

Certifications and Warnings

27

Product Warranty

28

Getting Started Everything you need to quickly get up and running.
3

INSTEON On/Off Module

Device Overview On Status LED Off
On Off Set Button
®

Buttons
Tap to turn on For dimmable responders: Double-tap to turn on instantly Press and hold to brighten
Tap to turn off For dimmable responders: Double-tap to turn off instantly Press and hold to dim
See sections on Basic Linking and Programming Wheel for set button functions

Installation Plug your appliance into the bottom of the On/Off Module and plug the On/Off Module into an unswitched wall outlet.

Leave Your Appliance On If your appliance's switch is OFF, the On/Off Module will be unable to remotely turn ON your appliance.

®

ON

4

INSTEON Links INSTEON devices can stand alone and function as a local switch or dimmer, but their real power comes when they are connected together to form a control system. Most INSTEON devices can control one another and be the recipient of control. The process of associating multiple INSTEON devices to one another is called Linking.
5

Understanding Linking

Links are One-Way When linking INSTEON devices, the links that are created are one-way.
NEW

A

B

Links Remember a Device's State The current state of the controlled device is stored in the link: on, off or dimmed.
NEW

75%

Switch

®
Lamp Dimmer

Switch A will turn Switch B on and off but
Switch B cannot turn Switch A oXn or off.

Controllers INSTEON devices that can turn other devices on or off are called controllers.
NEW

®

a

b

c

d

e

f

®

g

h

Sensors, Switches, Keypads and the
Hub are common controllers. X

The switch will turn on the Lamp Dimmer to

75% brightness.

X

Responders INSTEON devices that receive the command of a controller are called responders.
NEW

On

N

Off

Neutral

N

Set

Load L1 Line L ®
®

Switches, Keypads, Plug-In Modules and
In-Line Modules are common reXsponders.

6

Understanding Linking

Controller-Only Some devices like sensors can only control other devices.
NEW

Responder-Only Some devices cannot control other devices; these devices only receive INSTEON commands.
NEW

®
Motion Sensor

X Dimmer Switch

X

LED Bulb

Dimmer Switch

The Motion Sensor will turn on the Switch

but the Sensor.

switch

cannot

control

theXMotion

Grouping Devices You may want to group together two devices, for example, in a virtual-three way configuration. For INSTEON, this is called Cross Linking.
NEW

Some devices can only link as
responders to devices and sXcenes.
Use Cross Linking To Cross Link, simply turn on the devices and perform the linking process twice, once in each direction.
NEW

Load

A

B

To group Switch A and B so that they each

control one load, Cross

another Linking

iasnndectheesscaorny.Xnected

A

B

Link Switch A to Switch B and repeat to link

Switch B to Switch A.

X

7

Linking to the INSTEON Hub

1 From Rooms, navigate to All Devices.

2 Tap the Add button.

Rooms

All Devices

Check-In

Favorites

Bathroom

Bedroom

Hallway

Kitchen

Living Room

Outside

72º

All Devices Add

Back Door

Bathroom

Bedroom

Font Door

Garage Door Garage Light

Motion Sensor Outside Lights
72º

3

Select Plug-In Module form the list of devices.

Add Device

Plug-In Module Wired In

LED Bulb

Thermostat

4

When prompted, press and hold the set button on your On/Off Module

until the device double-beeps.

®

8

Linking with a Single-Button Controller

1

On your INSTEON controller, press and hold the set button until the

device beeps.

2

Make sure the On/Off Module is On and then press and hold the

On/Off Module's set button until

the device double-beeps.

®
NEW
®
Your INSTEON controller will now
control your On/Off ModuXle.
9

Linking with a Multi-Button Controller

1

On your INSTEON controller, tap the desired control button and

then press and hold the set button

until the device beeps.

2

Make sure the On/Off Module is On and then press and hold the

On/Off Module's set button until

the device double-beeps.

A
®
B

NEW

®
Your INSTEON controller will now
control your On/Off ModuXle.
10

Multi-Linking or Making a Scene

1

On your INSTEON controller, press and hold the set button until the

device beeps, then tap the set

button.

2

Adjust your scene members to their desired state: on, off, or

brightness level if dimming.

50%

72%

Lamp 1 Lamp 2

30%

ON

A B

3

One at a time, press and hold the set button on each scene member

until it double-beeps.

Lamp 3 Appliance

4

Tap the set button on your INSTEON controller to finish

building your scene.

NEW

®
Your INSTEON controller will
now control your scene.X
11

Unlinking from a Single-Button Controller

1

On your INSTEON controller, press and hold the set button until the

device beeps.

2

Press and hold the set button again until the device beeps.

3

Press and hold the On/Off Module's set button until the

device double-beeps.

®

NEW
X
®
Your INSTEON controller will no
longer control your On/OfXf Module.
12

Unlinking from a Multi-Button Controller

1

On your INSTEON controller, tap the desired control button and

then press and hold the set button

until the device beeps.

2

Press and hold the set button again until the device beeps.

A

B

3

Press and hold the On/Off Module's set button until the

device double-beeps.

®

NEW
X
®
Your INSTEON controller will no
longer control your On/OfXf Module.
13

Multi-Unlinking or Removing a Scene

1

On your INSTEON controller, press and hold the set button until the

device beeps. Press and hold the

set button again, then tap the set

button.

2

One at a time, press and hold the set button on each scene member

until it double-beeps.

A B C

3

Tap the set button on your INSTEON controller to exit Multi-

Unlinking mode.

®
®
NEW
X
®
®
Your INSTEON controller will no longer
control your INSTEON respXonders.
14

Local Programming Use tlohceallopcraolgprraomgrmamingmtinogsetot lsoectalloocna-l loevne-le, vraeml, rpamraptersaatensdaenvdenevpeenrform paefarfcotromryarefasceto. ry reset.
15

NEW
About Local Programming

Local Programming The Programming Wheel is a visual representation of the device's settings. Many device features can be configured using the Programming Wheel. Some devices have more options than others but the programming wheel presents even the most complicated devices with a straightforward, navigable path.

Navigation To move right, press and hold the set button To move down, tap the set button
X
Status LED blinks green Status LED double-blinks green Status LED blinks red Status LED double-blinks red

Local Programming Features

Linking Mode

Readies the module for linking to another INSTEON module. As linking is directional, the first device placed into linking mode will become the controller in the controller/responder relationship. The second device will become the responder. The device automatically exits linking mode after a link has been made with another INSTEON device or four minutes have elapsed without linking.

Multi-Linking Mode

Readies the module for linking to multiple INSTEON modules. The module will remain in linking mode for 4 minutes or until the module's set button is tapped. This mode is very usefully for manually creating scenes.

Unlinking Allows the removal of links from the INSTEON module. The device will automatically exit unlinking mode Mode after a link has been removed from another INSTEON device or four minutes have elapsed without linking.

MultiUnlinking
Mode

Allows the removal of multiple links from the INSTEON module. The device will stay in unlinking mode for 4 minutes or until the device's set button is tapped.

LED Allows adjusting the brightness level of the module's status LED. Brightness

RF Beacon Places the module in a mode that broadcasts a signal over INSTEON RF. Any devices beeping or displaying a blinking LED are within range of the module's RF signal.

Factory Erases any user-customized programming from the device including all INSTEON device links, scenes, Reset ramp rate, on-level, etc. A factory reset cannot be undone.

16

Local Programming Flow Chart

Linking Mode

Press

Unlinking Mode

Press

®

Press

Tap

Tap

Tap

Multi-Linking Mode
Select

Press Exit

MultiUnlinking Mode
Select

Tap Exit

Press Exit

LED Brightness
Select

Press

LED Brightness
Adjust

Press Cancel

Tap

Tap

Tap

Exit

Save

RF Beacon

Press

RF Beacon Toggle

Press Cancel

Tap

Factory Reset Select

Tap Toggle
Press Reset

Tap Cancel

17

Software-Only Features Most INSTEON devices contain features that can only be enabled, disabled or modified using INSTEON control software such as HouseLinc and an INSTEON PowerLine Modem or the INSTEON Hub.
18

Software-Only Features

Beep on Button Press
The On/Off Module will beep every time one of its buttons are tapped. By default, this feature is disabled.

Disable Local Programming
Prevents changing any settings using the set button or tap-and-hold programming. By default, this feature is disabled.

X

®

®

Blink on Traffic
The On/Off Module LED will blink if it detects INSTEON communication. By default, this feature is disabled.

Error Blink The On/Off Module LED will blink red once if one or more responders do not acknowledge a message and will blink green once if all responders successfully acknowledge a message. By default, this feature is enabled.
X

®

®

®

19

Appendix Everything else you might need to know about your INSTEON product.
20

INSTEON Glossary

Controller The INSTEON transmitter

Responder The INSTEON receiver

Blinking LED turning on and off repeatedly

Dual-Band An INSTEON device that can send and receive both INSTEON powerline signals and INSTEON radio frequency signals

Ramp Rate The speed at which the load fades on or off

On-Level The preset brightness level a device will return to when turned on

INSTEON A dual-band, mesh networking technology developed by Smarthome/INSTEON. The world's most reliable, expandable and simple home automation and control technology.

Link A one way association between a controller and responder

Linking

A method for associating INSTEON controller buttons with groups of INSTEON responders such that the responders instantly return to a memorized state when the button is pushed. Links can be made manually with the set button or using software.

Unlinking

The process by which an INSTEON device can remove stored links. Just as with linking, unlinking is a one-way process and should be performed in both directions for devices that are both controllers and responders of each other, as in a 3-way switch scenario.

Multi-Linking / Unlinking

A special mode that allows more than one link to be either created or removed simultaneously, without laborious set button presses. When in linking or unlinking mode, an INSTEON device will continue to link to other devices until the set button is tapped or four minutes have elapsed, whichever occurs first.

Factory A process that erases all stored links and reconfigures the device to factory defaults. Reset

Load The device that you are controlling (e.g. a light bulb, ceiling fan, etc.)

On/Off A device that can control its connected load to turn on and off but cannot dim. Usually a relay-based device.

Retry A 2nd (or subsequent) attempt by a controller to send an INSTEON signal, usually after an acknowledge is not received from the responder in the expected time-slot.

Scene

Multiple devices respond to memorized states. For example, a dinner time scene turns on the dining table light, dims the kitchen lights to 10%, backyard lights turn off and the thermostat adjusts to 72º.

Set Button A button on an INSTEON device that is used for setting or changing its properties

Simulcast

A method for increasing the reliability of message delivery in a network. When a node in a network sends a message, every other node that hears the message retransmits it at precisely the same time based on a global clock, provided that the message has not already been retransmitted some maximum number of times. Message propagation is more robust because each node adds its energy to the signal, much like voices in a choir. Simulcasting is much simpler than message routing because there are no routing tables to maintain and nodes can join the network without any installation procedure.

X10 A legacy powerline networking technology. Many INSTEON devices are backwards compatible with X10 devices by setting a house and unit code.

21

Specifications
General Available Colors White Brand: INSTEON FCC ID SBP26352 Industry Canada 5202A-26352
Manufacturer Product No.: 2635-222 Patent No.: Protected under US and Foreign Patents (see www.insteon.com/ patents) UPC: 813922013368 Warranty: 2 years, limited

Operation

Audio Alert Beeper, can be disabled through software Operation Modes INSTEON only
Load Sensing No Local Control Yes Setup Memory Non-volatile EEPROM
Status LED Red/Green LED

INSTEON Features INSTEON Device Category 0x02 appliance control
INSTEON Device Subcategory 0x37 INSTEON ID 1
INSTEON Links 417 INSTEON Messages Repeated Yes INSTEON Minimum Receive Level 10 mV INSTEON Minimum Transmit Level 3.2 Vpp into 5 Ohms
INSTEON Powerline Device Yes INSTEON Powerline Frequency 131.65 KHz
INSTEON RF Device Yes Maximum Controlled Scenes 1

22

Maximum Scene Memberships 400

Multi-Link Support Yes

Multi-Unlink Support Yes

RF Beacon Yes

Radio Frequency 915.0 MHz

Radio Frequency Range 150 feet

Scene Commands Supported as Controller

On Fast-On

Begin Brighten

End Brighten

Scene Commands Supported as Responder

On Fast-On

Beep

Software Configurable Yes

Off Fast-Off Begin Dim End Dim Off Fast-Off

Mechanical
Dimensions 3.24" H x 2.08" W x 2.02" D 82.5mm H x 53mm W x 51.5mm D
Dimming Technology Employed Relay - On/Off only
Enclosure Material UV stabilized plastic
Mounting Grounded electrical outlet, NEMA 5-15
Operating Environment Indoors
Operating Humidity Range 0-90% relative humidity, non-condensing
Operating Temperature Range 32º to 104º F 0º to 40º C
Set Button Yes
Storage Temperature Range -4º to 158º F -20º to 70º C
Weight 5.2 oz

23

Electrical

Controlled Outlet Yes, grounded. NEMA 5-15 type

Hardwired Remote Control No

Load Types General Appliances

15A Max

Resistive

15A Max

Incandescent

1,800W Max

Motors

1HP Max

Ballasts

10A Max

Maximum Load 1,800 Watts (15 Amps)

Minimum Load None

Pass-through Outlet No

Power Consumption <0.75 Watts

Supply Voltage 120 Volts AC ± 10%, 50/60 Hertz, single phase

Surge Resistance Surges over 1,000 volts

X10 Features (Powerline Only) X10 Support No

24

Troubleshooting
On/Off Module LED does not turn on It is possible your On/Off Module is not receiving power. If the attached load can still be controlled, It is possible that the status LED has been disabled.
Try this: · Test On/Off Module in a different power outlet. If the LED illuminates when using a different outlet, check
the original outlet for power. Some outlets are controlled by a switch elsewhere in the room. Avoid switched outlets as they disable your INSTEON device when turned off.
· If the outlet works and the connected load can be toggled, use software or the programming wheel to change the behavior of the status LED. The status LED brightness can be dimmed to the point that it appears off. HouseLinc allows setting of this device property.
Unable to add On/Off module to a scene as a controller or a responder If the device has power, something is likely interfering with the INSTEON signal. Large appliances, power strips and some electronic devices may generate powerline noise.
Try this: · Check to see if you have connected On/Off Module to a power strip, surge suppressor, backup battery or
AC line filter. These devices often filter out the INSTEON powerline signal. Relocate the On/Off Module to a standard AC outlet.
· Large appliances like refrigerators or air conditioners may be generating powerline noise that is disrupting the INSTEON signal. If the issue only appears to happen when one of these large appliances is running, install a noise filter at that device. If you are uncertain of the device generating the noise, disconnect the potentially offending devices from power and test your On/Off Module again. If the issue is resolved, install noise filters at each offending appliance.
· Some small electronics devices that include an AC/DC power supply can generate substantial electrical noise, in some cases, enough to disrupt an entire house of INSTEON devices. Search your home for speaker docks, small stereos, etc. and disconnect them from power to perform testing. If removing these devices from your powerline resolves the INSTEON issue, install a noise filter at each offending small electronic appliance.
· Your On/Off Module may be too far from another INSTEON device to receive a signal. Try locating the On/ Off Module closer to another INSTEON device and if the issue is resolved, install a Range Extender or other Dual-Band INSTEON device between the intended location of your On/Off Module and the next nearest INSTEON device.
The On/Off Module is slow to respond to commands from a controller This issue most likely lies with the controller, not the On/Off Module; the controller is most likely repeating commands not acknowledged by an INSTEON device that has been removed from the network. The repeated commands are slowing down the INSTEON network, resulting in a delayed response from the On/Off Module.
Try this: · Consider if you have removed any INSTEON devices from you network that were part of the slow-to-
respond scene. If so, the links to these devices need to be removed from the controller. Use software to examine the database of the controller or if you know the modules that were removed, manually remove their links using the standard unlinking procedure.
· If you are unable to identify the missing devices, perform a factory reset on the controller. This will remove all links from the controller's database but will also require that you reconfigure the device's scenes and properties.
25

Troubleshooting The connected appliance turned on by itself There must be a device in your INSTEON network that is unexpectedly linked to the On/Off Module Try this: · Use software to examine the On/Off Module's links. If you can identify the stray controller, remove the link. · If you are unable to identify the unexpected controller, perform a factory reset on the On/Off Module. This
will remove all links from the module's database but will also require that you reconfigure the device's scenes and properties.
Using a controller, On/Off Module will turn off but not turn on Most likely, the On/Off Module was linked to the controller with the load set to Off Try this: · Make sure the On/Off Module's connected load is on and then re-link the device to your INSTEON
controller. This link will overwrite the previous "off" link.
On/Off Module does not respond to button taps or controller links A power surge or excessive powerline noise may have caused the module to unexpectedly stop responding. Try this: · Unplug On/Off Module for 10 seconds and then reconnect the device to power. Test the local buttons to
see if the load will turn on or off. · While unusual, On/Off Module may require a factory reset to restore normal operation. Follow the
procedure outlined in the Programming Wheel to reset the device to factory settings. You will be required to reconfigure the device's scenes and properties after the reset.
When using the connected load's switch, the load does not turn on Your load may not be receiving power if the On/Off Module is off. Try this: · Use the buttons on the side of the On/Off Module to turn on the connected device. Remember, if the
connected load is turned off using its own switch, On/Off Module is unable to control the device. · If your connected load is a lamp, check the bulb. It is possible that your light bulb needs to be replaced.
26

Certifications and Warnings
Read and understand these instructions before installing and retain them for future reference. This product is not designed or approved for use on powerlines other than 120VAC, 50Hz or 60Hz, single phase. Attempting to use this product on unapproved powerlines may have hazardous consequences. · Use only indoors or in outdoor rated box · This product may feel warm during operation. The amount of heat generated is within approved limits and
poses no hazards. To minimize heat buildup, ensure the area surrounding this product is as clear of clutter as possible. · Each INSTEON product is assigned a unique INSTEON I.D., which is printed on the product's label. · To reduce the risk of overheating and possible damage to other equipment, do not use this product to control loads in excess of the specified maximum(s) or, install in locations with electricity specifications which are outside of the product's specifications. If this device supports dimming, please note that dimming an inductive load, such as a fan or transformer, could cause damage to the dimmer, the load bearing device, or both. If the manufacturer of the load device does not recommend dimming, use a non-dimming INSTEON device. USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD. This device complies with FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. CAUTION - To reduce the risk of overheating and possible damage to other equipment do not install to control a receptacle, a motor-operated appliance, a fluorescent lighting fixture, or a transformer-supplied appliance. Gradateurs commandant une lampe a filament de tungstene ­ afin de reduire le risqué de surchauffe et la possibilite d'endommagement a d'autres materiels, ne pas installer pour commader une prise, un appareil a moteur, une lampe fluorescente ou un appareil alimente par un transformateur. DECLARATION OF CONFORMITY Hereby, INSTEON declares that this device is in compliance with the essential requirements and other relevant provisions of the following Directives: 1) Electromagnetic Compatibility Directive 2004/108/EC 2) Hazardous Substance Directive 2005/95/EC Technical data and copies of the original Declaration of Conformity are available and can be obtained from INSTEON; 16542 Millikan Ave, Irvine, CA, USA.
27

Product Warranty
Limited Warranty
Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner's Manual. This warranty shall not apply to defects or errors caused by misuse or neglect. If the product is found to be defective in material or workmanship, or if the product does not perform as warranted above during the warranty period, Seller will either repair it, replace it, or refund the purchase price, at its option, upon receipt of the product at the address below, postage prepaid, with proof of the date of purchase and an explanation of the defect or error. The repair, replacement, or refund that is provided for above shall be the full extent of Seller's liability with respect to this product. For repair or replacement during the warranty period, call 866-243-8022 with the Model # and Revision # of the device to receive an RMA# and send the product, along with all other required materials to:
INSTEON ATTN: Receiving 16542 Millikan Ave. Irvine, CA 92606-5027
Limitations
The above warranty is in lieu of and Seller disclaims all other warranties, whether oral or written, express or implied, including any warranty or merchantability or fitness for a particular purpose. Any implied warranty, including any warranty of merchantability or fitness for a particular purpose, which may not be disclaimed or supplanted as provided above shall be limited to the two-year of the express warranty above. No other representation or claim of any nature by any person shall be binding upon Seller or modify the terms of the above warranty and disclaimer.
Home automation devices have the risk of failure to operate, incorrect operation, or electrical or mechanical tampering. For optimal use, manually verify the device state. Any home automation device should be viewed as a convenience, but not as a sole method for controlling your home.
In no event shall Seller be liable for special, incidental, consequential, or other damages resulting from possession or use of this device, including without limitation damage to property and, to the extent permitted by law, personal injury, even if Seller knew or should have known of the possibility of such damages. Some states do not allow limitations on how long an implied warranty lasts and/or the exclusion or limitation of damages, in which case the above limitations and/or exclusions may not apply to you. You may also have other legal rights that may vary from state to state.

Protected under U.S. and foreign patents (see www.insteon.com/patents) © Copyright 2013 INSTEON

Rev 10.23.13

28


Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Macintosh)

Related Documents

Preview INSTEON On/Off Outdoor Module 2634-222 Owner's Manual
Comprehensive owner's manual for the INSTEON On/Off Outdoor Module (Model 2634-222), covering installation, setup, operation, troubleshooting, specifications, and warranty information.
Preview Getting Started with Insteon On/Off Module | Insteon Smart Home Setup
Quick start guide for setting up the Insteon On/Off Module. Learn how to connect devices, pair with the Insteon app, and unlock advanced features like schedules and scenes for your smart home automation.
Preview INSTEON ApplianceLinc 2456SE Outdoor Plug-In Appliance On/Off Module User Manual
Comprehensive user manual for the INSTEON ApplianceLinc 2456SE Outdoor Plug-In Appliance On/Off Module, covering installation, operation, advanced features, troubleshooting, and warranty information.
Preview INSTEON On/Off Module 2635-222 Quick Start Guide
Quick start guide for the INSTEON On/Off Module (Model 2635-222), detailing installation, linking to the INSTEON Hub, and basic device control for smart home automation.
Preview Insteon Dimmer Module Owner's Manual - Smart Home Lighting Control
Comprehensive owner's manual for the Insteon Dimmer Module (Model 2457D2). Learn about installation, device overview, linking with controllers and hubs, manual linking, local programming, troubleshooting, specifications, and warranty information for your smart home lighting system.
Preview INSTEON Outdoor On/Off Module Quick Start Guide
Quick start guide for the INSTEON Outdoor On/Off Module, detailing installation, linking to the INSTEON Hub, and basic device control for outdoor lighting and appliances.
Preview Insteon Alert Module 2867-222 Owner's Manual
Comprehensive owner's manual for the Insteon Alert Module (Model 2867-222), covering setup, installation, alert types, local programming, factory reset, specifications, troubleshooting, and warranty information.
Preview INSTEON Starter Kit Quick Start Guide - Smart Home Automation
Get started with your INSTEON Starter Kit. This guide provides instructions for setting up your Hub, adding dimmer modules, and exploring remote access and scheduling features for your smart home.