AprilAire Ventilating Dehumidifier
Models E100V/8190FF
Features
- E100V Dehumidifier is wired specifically for use with the 8190FF Ventilation Plenum.
- Patent-pending ventilation design.
- Removes moisture from outdoor air before it enters the living space.
- Unit is designed, when properly installed, to achieve ASHRAE Standard 62.2.
- Integral moisture and ventilation control.
- High and low temperature limit lock-outs.
- Simple plug-in installation.
- Installation temperature range up to 140°F.
- Optional dehumidification control via thermostats (see below).
Specifications
Specification | Value |
---|---|
Nominal ventilation airflow (CFM) | 150 CFM |
Capacity pints/day | 100 ppd |
Energy factor(1) | 2.6 L/kW-h (5.5 pints/kW-h) |
Airflow @ varying E.S.P. (external static pressure - dry coil) |
0.0" w.c.: 280 CFM |
0.2" w.c.: 245 CFM | |
0.4" w.c.: 210 CFM | |
Voltage, phase, frequency | 120VAC, 1 phase, 60 Hz |
Current draw(1) | 6.9 Amps |
Noise-Fan Only | 52.8 dBA (ducted) |
Noise-Compressor and Fan | 55.0 dBA (ducted) |
Dimensions (combined cabinets)(2) | Width: 14 1/2" |
Height: 23 1/2" w/o adjustable feet | |
Length: 48 1/4" | |
Weights | E100V Unit Weight: 64 lbs. |
E100V Shipping Weight: 82 lbs. | |
8190FF Unit Weight: 13.7 lbs. | |
8190FF Shipping Weight: 16.8 lbs. | |
Inlet air operating conditions during | Dehumidification: 50°F–104°F, 40°F dew point min. |
Ventilation: 40°F–140°F, 0%–99% RH | |
Control Cabinet Solution | Built-in digital control with display |
Air discharge orientation | Top |
Inlet/Outlet duct collars | 10" round |
Backflow damper at outlet | Included |
Air filter | Washable MERV 8 |
Refrigeration Coil type | Corrosion-resistant aluminum |
8' Power cord type | Plug type |
Drain connection(3) | 3/4" PVC adapters |
Warranty | 5 Years |
(1)Rated capacity, energy factor and current draw measured at 80°F/60% RH inlet air at 0.0 ESP.
(2)Height does not include adjustable feet. Length includes the duct collars, and width includes the filter doors.
(3)Thread adapter and barbed fitting for clear drain tubing included.
Benefits
- Helps control RH in the home during periods when the air conditioning system does not run long enough to remove sufficient moisture. If air conditioner can satisfy RH requirements, the AprilAire unit's compressor shuts off.
- Optimizes energy savings by locking out ventilation during the hottest/coldest times of the day.
- Improves indoor air quality.
- Installation labor is reduced, requiring only a power outlet and 24-volt wiring to the HVAC system.
- When properly installed and set, the AprilAire Ventilating Dehumidifier will meet the mechanical ventilation requirements of:
- ASHRAE 62.2
- Energy Star Certified Homes
- EPA Indoor airPLUS
- International Residential Code (IRC)
Dimensions and Physical Description
The unit features a width of 14 1/2 inches, a height of 23 1/2 inches (excluding adjustable feet), and a length of 48 1/4 inches (including duct collars). The E100V dehumidifier unit weighs 64 lbs and has a shipping weight of 82 lbs. The 8190FF ventilation plenum unit weighs 13.7 lbs and has a shipping weight of 16.8 lbs. The product includes a 5-year warranty and is designed and assembled in the USA using U.S. and global components.
Control Panel Description
The integrated digital control panel features an ON/OFF button to turn the ventilator on and off. A MODE button is used to access the ventilation time setting. UP/DOWN buttons are used to change humidity or vent time settings.
Ducting the Ventilating Dehumidifier
Attic Installation
This configuration involves a fresh air intake hood with a screen, connected via a fresh air intake duct to the dehumidifier unit. The unit's air discharge is connected to an intake grill, which then connects to a return mixing box that integrates with the furnace or air handler.
Basement Installation
In this setup, air is pulled from outside through a duct and connected to the HVAC/Furnace. A minimum 6-foot duct run is recommended.
Recommended Controls
AprilAire Thermostat Models
- 8620, 8620W, 8910, 8910W, 8920W
AprilAire Communicating Thermostat Models
- 8820, 8830, 8840
Zone Control Systems
- 6010, 6015, 6020, 6025, 6030, 6035, 6040, 6045