DOD Mini Volume Pedal Owner's Manual
Thank you for purchasing the DOD Mini Volume Pedal, a passive miniature volume pedal that offers complete volume control without taking up valuable space on your pedalboard.
Features
- Compact size that takes up minimal space on your pedalboard
- Full-range sweep for complete control
- High-quality 500-kΩ potentiometer with a high-frequency response for smooth volume control
- Built-in treble bleed circuit prevents treble loss at low volumes
- Detachable rubber feet for pedalboard mounting
- 1/4-inch TS input and output jacks
- Non-slip pedal surface
- Rugged construction
Setup
- Turn off your amplifier and connect your cables (see connection diagram below).
- Turn down your amplifier's volume, press the toe of the DOD Mini Volume Pedal down, and then turn on your amplifier.
- Slowly increase your amplifier's volume until the desired level is reached.
Connection Diagram Description: The diagram illustrates a typical guitar effects setup. A guitar is connected to a series of effect pedals, which then connect to the DOD Mini Volume Pedal. The output of the volume pedal goes to an amplifier. The text 'USE ONLY UNBALANCED TS CABLES' is prominently displayed.
Important Note on Usage
The two hex screws on the underside of the pedal are part of the spring-loaded adjustment mechanism. If you notice play over time, slightly loosen these screws and then retighten them. This presses the main gear back against the pedal gear.
DO NOT remove these screws or operate the pedal while the screws are loosened. This can cause the gears to become misaligned and the pedal to malfunction. There are no user-serviceable parts inside the pedal. The pedal must not be opened under any circumstances.
Compliance and Safety Information
Altitude Warning: This product should not be used at altitudes above 2,000 meters (approx. 6,560 feet).
Symbol Key: The symbols shown are internationally recognized warnings for potential hazards associated with electrical products. The lightning bolt with an arrow (⚡️) in a triangle indicates that dangerous voltages are present within the unit. The exclamation mark (❗) in a triangle indicates that the user must consult the operating manual.
These symbols also indicate that there are no user-serviceable parts inside the unit. Do not open the unit. Do not attempt to service the unit yourself. Refer all servicing to qualified personnel. Opening the unit for any reason will void the manufacturer's warranty.
Do not get the unit wet. If liquid is spilled on the unit, turn it off immediately and take it to a dealer for servicing. Disconnect the unit from power during thunderstorms (⛈️) to prevent damage.
British Mains Plug Warning
A molded mains plug that has been cut off from the cord is unsafe. Dispose of the plug at a suitable disposal facility. NEVER plug a damaged or cut-off mains plug into a 13-amp socket. Do not use the plug without the fuse cover. Replacement fuse covers are available from your local dealer. Replacement fuses are 13 Ampere and MUST be ASTA approved to BS1362.
Product Disposal
If you wish to dispose of this product, do not mix it with normal household waste. There is a separate collection system for used electronic products in accordance with legislation that mandates proper treatment, recovery, and recycling. Households in the 25 EU member states, Switzerland, and Norway can return their used electronic products free of charge to designated collection points or to retailers (when purchasing a similar new product). For countries not listed above, please contact your local authorities for proper disposal methods. This ensures that your disposed product undergoes the required treatment, recovery, and recycling, and prevents potential negative impacts on the environment and human health.
General Safety Warnings
FOR YOUR PROTECTION, PLEASE READ THE FOLLOWING:
- READ THESE INSTRUCTIONS.
- KEEP THESE INSTRUCTIONS.
- HEED ALL WARNINGS.
- FOLLOW ALL INSTRUCTIONS.
- DO NOT USE THIS APPARATUS NEAR WATER.
- CLEAN ONLY WITH A DRY CLOTH.
- FOR INDOOR USE ONLY.
Installation and Usage Guidelines
- DO NOT block any of the ventilation openings. Install the unit according to the manufacturer's instructions.
- DO NOT install the unit near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
- USE ONLY accessories/accessories specified by the manufacturer.
- Unplug the unit during thunderstorms (⛈️) or when unused for long periods.
- Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades, one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are for your safety. If the provided plug does not fit into your outlet, consult an electrician to replace the obsolete outlet.
- Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
- Use only with the cart, stand, tripod, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
Maintenance
Have all servicing performed by qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when the power-supply cord or plug is damaged, liquid has been spilled, or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Power Information
ON/OFF SWITCH: The power switch used in this unit does NOT interrupt the connection to the power source.
POWER DISCONNECTION: The plug must remain readily operable. For rack-mounted or permanently installed apparatus where the plug is not accessible, an all-pole mains switch with a contact separation of at least 3 mm in each pole must be incorporated into the electrical installation of the rack or building. When connecting to a 240 V supply, a suitable CSA/UL-certified power cord must be used for this supply.
Power Cord Wiring
NOTICE TO CUSTOMER, IF YOUR UNIT IS EQUIPPED WITH A POWER CORD.
WARNING: THIS UNIT MUST BE CONNECTED TO A GROUNDED OUTLET (?).
The conductors of the power cord are colored in accordance with the following code:
- GREEN AND YELLOW – EARTH
- BLUE – NEUTRAL
- BROWN – LIVE
Since the colors of the conductors of the power cord of this unit may not correspond with the colored markings of the terminals in your plug, proceed as follows:
- The GREEN AND YELLOW colored wire MUST be connected to the terminal in the plug marked with the letter E or with the EARTH symbol (?) or colored GREEN or GREEN AND YELLOW.
- The BLUE colored wire MUST be connected to the terminal marked with N or BLACK.
- The BROWN colored wire MUST be connected to the terminal marked with L or RED.
This unit may require the use of a different power cord, a different plug connector, or both, depending on the power source available at installation. If the plug connector needs to be changed, have the maintenance performed by qualified service personnel, referring to the table below. The GREEN/YELLOW cable must be connected directly to the unit chassis.
CONDUCTOR | WIRE COLOR (Normal) | WIRE COLOR (Alt) |
---|---|---|
L (LIVE) | BROWN | BLACK |
N (NEUTRAL) | BLUE | WHITE |
E (EARTH) | GREEN/YEL | GREEN |
CAUTION: IF THE GROUNDING IS INTERRUPTED, CERTAIN FAULT CONDITIONS IN THE UNIT OR SYSTEM TO WHICH IT IS CONNECTED MAY CAUSE FULL LINE VOLTAGE TO BE PRESENT BETWEEN THE CHASSIS AND GROUND. SEVERE INJURY OR DEATH CAN THEN RESULT IF THE CHASSIS AND GROUND ARE TOUCHED SIMULTANEOUSLY.