Proximity Switch For Activation and Access Control
“
Product Information
Specifications:
- Proximity switch for activation and access control
- Hard coated, scratch resistant, anti-reflective, anti-microbial
Steritouch acrylic label - Entire label is sensitive
- Radio Frequency: 868MHz
- Power Supply: 4 x AA batteries for the unit, 12/24Vdc for the
receiver - Approximately 100,000 operations battery life
- Dimensions: Unit – (specific dimensions not provided), Receiver
– 65 x 50 x 30 mm
Product Usage Instructions
Installation:
- Ascertain the fixing height.
- Use the back plate to mark cable hole and screw fixing
points. - Fix the top retaining screw (No 8 or 10) leaving 4mm of screw
shaft protruding. - Fit the back seal to the rear of back plate (if being installed
externally). - Place the cable through back plate and make connections or
connect battery clip and program to receiver. - Place the back plate in position, hook unit onto the top
retaining screw and fit the bottom retaining screw.
Wiring Diagrams:
Refer to the provided wiring diagrams for hardwired sensor
wiring and alter LED color configuration as required.
Radio Programming (RX-2):
- Supply receiver with 12/24Vdc power.
- Wire relay outputs to activate terminals on the system (clean,
normally open contacts). - Press and release the learn button, then operate the touch
sensor within 15 seconds to program it. - To reset the receiver, press and hold the learn button for 10
seconds until the learn LED starts flashing.
FAQ
Q: How do I reset the receiver?
A: To reset the receiver, press and hold the learn button for 10
seconds until the learn LED starts flashing. After this, the memory
will be deleted.
Q: What is the approximate battery life of the unit?
A: The unit has an approximate battery life of 100,000
operations.
“`
Installation:
ARCHITRAVE & ROUND Manual
Proximity switch for activation and access control
Hard coated, scratch resistant, anti-reflective, anti-microbial Steritouch acrylic label Entire label is sensitive www.quantek.co.uk 01246 417113
Ascertain the fixing height.
Use the back plate to mark cable hole and screw fixing points, round unit can be angled towards approaching users.
Fix the top retaining screw (No 8 or 10) leaving 4mm of screw shaft protruding.
Fit the back seal to the rear of back plate (if being installed externally)
Place the cable through back plate and make connections (see below) or connect battery clip and program to receiver (see next page).
Place the back plate in position, hook unit onto the top retaining screw and fit the bottom retaining screw.
Hardwired specification: 12 28v dc 8mA (standby) / 35mA (max) +18mA LEDs Sensitivity – Touch – up to 70mm hands free Selectable red, green, blue LEDs Sounder on activation Timer 1 – 27 seconds Latching function
Architrave Round
Wiring diagrams
Hardwired sensor wiring. Alter LED colour configuration as required.
Normally open contacts. 0v return
12-28Vdc NO activate
0V return 0V
Latch jumper Momentary Latching
Normally open contacts. +v return
12-28Vdc NO activate
+V return 0V
Remote switch
N.O. (Optional)
Sensitivity dip-switches
1 – Low 4 – High Remove power alter range re power
Sounder
Timer
1-27 seconds Anti-clockwise to increase time
Note: Never connect anything to RD terminal
Radio programming (RX-2)
Supply receiver with 12/24Vdc power. +V to 12/24V terminal, -V to GND terminal. LED will light if powered correctly
Wire relay outputs to activate terminals on the system (clean, normally open contacts)
Press and release the learn button, the learn LED will light up for 15 seconds
Within the 15 seconds operate the touch sensor
The learn LED will flash to confirm it has programmed Note: Touch sensors program to channel 1. The RX-T receiver will be required if you need to program them to different channels. It is also possible to program our handheld and desk mount transmitters (CFOB, FOB1-M, FOB2-M, FOB2-MS, FOB4- M, FOB4-MS, DDA1, DDA2) into this receiver using the same method. See transmitter box for more details.
Reset: To reset the receiver, press and hold the learn button for 10 seconds until the learn LED starts flashing. After this the memory will be deleted
Radio specification
868MHz 4 x AA batteries Approximately 100,000 operations Sounder & green LED on activation Battery saving design, unit will only activate once if hand left on
Receiver specification
12/24Vdc supply 868MHz 2 channels 1A 24Vdc normally open contacts Momentary/bi-stable selectable relays 200 code memory Dimensions: 65 x 50 x 30 mm
Dipswitch settings
ON
OFF
1
CH1 – Bi-Stable
CH1 – Momentary
2
CH2 – Bi-Stable
CH2 – Momentary
Programming video
Documents / Resources
![]() |