ARCHITRAVE & ROUND Manual
Proximity switch for activation and access control
Hard coated, scratch resistant, anti‐reflective, anti‐microbial Steritouch acrylic label Entire label is sensitive
www.quantek.co.uk 01246 417113
![]()
Installation:
Ascertain the fixing height.
Use the back plate to mark cable hole and screw fixing points, round unit can be angled towards approaching users.
Fix the top retaining screw (No 8 or 10) leaving 4mm of screw shaft protruding.
Fit the back seal to the rear of back plate (if being installed externally)
Place the cable through back plate and make connections (see below)
or connect battery clip and program to receiver (see next page).
Place the back plate in position, hook unit onto the top retaining screw and fit the bottom retaining screw.

Hardwired specification:
12 – 28v dc
8mA (standby) / 35mA (max) +18mA LEDs
Sensitivity – Touch – up to 70mm hands free
Selectable red, green, blue LEDs
Sounder on activation
Timer 1 – 27 seconds
Latching function
Wiring diagrams
Hardwired sensor wiring. Alter LED colour configuration as required.

Radio programming (RX-2)
Supply receiver with 12/24Vdc power. +V to 12/24V terminal, -V to GND terminal. LED will light if powered correctly
Wire relay outputs to activate terminals on the system (clean, normally open contacts)
Press and release the learn button, the learn LED will light up for 15 seconds
Within the 15 seconds operate the touch sensor
The learn LED will flash to confirm it has programmed
Note: Touch sensors program to channel 1. The RX‐T receiver will be required if you need to program them to different channels.
It is also possible to program our handheld and desk mount transmitters (CFOB, FOB1-M, FOB2‐M, FOB2-MS, FOB4‐ M, FOB4-MS, DDA1, DDA2) into this receiver using the same method. See transmitter box for more details.
Reset: To reset the receiver, press and hold the learn button for 10 seconds until the learn LED starts flashing. After this the memory will be deleted
Radio specification
868MHz
4 x AA batteries
Approximately 100,000 operations Sounder & green LED on activation
Battery saving design, unit will only activate once if hand left on
Receiver specification
12/24Vdc supply
868MHz
2 channels
1A 24Vdc normally open contacts
Momentary/bi‐stable selectable relays 200 code memory
Dimensions: 65 x 50 x 30 mm

Dipswitch settings
| ON | OFF | |
| 1 | CH1 ‐ Bi‐Stable | CH1 ‐ Momentary |
| 2 | CH2 ‐ Bi‐Stable | CH2 ‐ Momentary |
Programming video

https://www.youtube.com/watch?v=oqcPXfnqKvc
Documents / Resources
![]() |
Quantek Proximity Switch For Activation and Access Control [pdf] Instructions TS-A-R, TS SQ, Proximity Switch For Activation and Access Control, Switch For Activation and Access Control, Activation and Access Control, and Access Control, Access Control |