MEAN WELL PWM-200 Series 200W Constant Voltage PWM Output LED Driver
Specifications
Product Usage Instructions
Installation:
Ensure the input voltage is within the specified range for the model you are using.
Connect the LED driver according to the wiring diagram provided in the manual.
Dimming
Adjust the dimming range as needed using the specified PWM frequency for your model.
Powering On
Apply power to the LED driver and ensure it stabilizes within the hold-up time mentioned in the specifications.
Troubleshooting
Refer to the user manual for troubleshooting steps in case of any issues with the LED driver.
Frequently Asked Questions (FAQ)
Q: What is the dimming range for PWM-200 series LED drivers?
A: The dimming range is from 0% to 100% for all models in the PWM-200 series.
Features
- Constant voltage PWM style output with frequency up to 4kHz design compliant IEEEI 789-2015(Blank type)
- Plastic housing with class 11 and PFC design
- Emergency lighting application is available according to IEC61347-2-13
- Standby power consumption <O.5W
- Fully encapsulated with IP67 level
- Function options: 3 in 1 dimming (dim-to-off and Isolated Design)/DALl-2
- Minimum dimming level 0.2% for DA2 type
- Typical lifetime >50000 hrs and 5 years warranty
Applications
- LED strip lighting
- Indoor LED lighting
- LED decorative lighting
- LED architecture lighting
- Cove lighting
Industrial lighting
Type “HL” for use in class l, division 2 hazardous (classified) location.
GTIN CODE
MW Search: http://www.meanwell.com/serviceGTlN.aspx
Description
PWM-200 series is a 200W AC/DC LED driver featuring the constant voltage mode with PWM style output, which is able to maintain the color temperature and the brightness homogeneity when driving all kinds of LED strips. PWM-200 operates from 100—305VAC and offers models with different rated voltage ranging between 12V and 48V. Thanks to the high efficiency up to 94% with the fanless design, the entire series is able to operate for -400C +850C case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for dry, damp or wet locations. PWM-200 is equipped with dimming function that varies the duty cycle of the output, providing great flexibility for LED strips applications.
Model Encoding
SPECIFICATION
MODEL | PWM-200-12 | PWM-200-24 | PWM-200-36 | PWM-200-48 | |||
OUTPUT | DC VOLTAGE | 12V | 24V | 36V | 48V | ||
RATED CURRENT | 15A | 8.3A | 5.55A | 4.17A | |||
RATED POWER | 180W | 199.2W | 199.8W | 200.1W | |||
DIMMING RANGE | 0 ~ 100% | ||||||
PWM FREQUENCY (Typ.) | 4kHz for Blank type; 2.5kHz for DA2 type | ||||||
SETUP, RISE TIME Note.2Note.10 | 500ms, 80ms/230VAC or 115VAC | ||||||
HOLD UP TIME (Typ.) | 10ms/230VAC or 115VAC | ||||||
INPUT | VOLTAGE RANGE Note.3 | 100 ~ 305VAC 142 ~ 431VDC(Please refer to “STATIC CHARACTERISTIC” section) | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR (Typ.) | PF>0.97/115VAC, PF>0.96/230VAC, PF>0.94/277VAC @ full load(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) | ||||||
TOTAL HARMONIC DISTORTION | THD<20%(@load≧60%/115VAC, 230VAC; @load≧75%/277VAC)(Please refer to “TOTAL HARMONIC DISTORTION” section) | ||||||
EFFICIENCY (Typ.) | 92% | 93% | 94% | 94% | |||
AC CURRENT (Typ.) | 2.2A / 115VAC 1.1A / 230VAC 0.9A / 277VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 65A(twidth=55μ0 s measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||||
MAX. NO. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | ||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||||
STANDBY POWER CONSUMPTION | standby power consumption<0.5W when dimming off | ||||||
PROTECTION | OVERLOAD | 108 ~ 135% rated output power | |||||
Hiccup mode or Constant current limiting,recovers automatically after fault condition is removed | |||||||
SHORT CIRCUIT | Shut down o/p voltage, re-power on to recover (except for DA2-type)Hiccup mode,recovers automatically after fault condition is removed (only for DA2-type) | ||||||
OVER VOLTAGE | 13 ~ 18V | 27 ~ 34V | 41 ~ 49V | 53 ~ 65V | |||
Shut down o/p voltage, re-power on to recover after fault condition is removed | |||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover after fault condition is removed | ||||||
ENVIRONMENT | WORKING TEMP. | Tcase=-40 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | |||||
MAX. CASE TEMP. | Tcase=+85℃ | ||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||||
SAFETY & EMC | SAFETY STANDARDS Note.5 | UL8750( type ”HL” ), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13,BS EN/EN62384independent, IP67, EAC TP TC 004,GB19510.1,GB19510.14, IS15885(Part2/Sec13)(except for 36V) approved; Design refer to BS EN/EN60335-1, According to BS EN/EN61347-2-13 appendix J suitable for emergency installations | |||||
DALI STANDARDS | Comply with IEC62386-101, 102, 207, 251 for DA2 Type only, Device type 6(DT6) | ||||||
WITHSTAND VOLTAGE | I/P-O/P: 3.75KVAC; I/P-DA: 1.5KVAC; O/P-DA:1.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION Note.6 | Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3,GB/T 17743, GB17625.1;EAC TP TC 020 | ||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity, Line-Line 2KV),EAC TP TC 020 | ||||||
OTHERS | MTBF | 2235.6K hrs min. Telcordia SR-332 (Bellcore) ;178.7K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 195*68*39.5mm (L*W*H) | ||||||
PACKING | 1.03Kg; 12pcs/ 13.4Kg/ 0.71CUFT | ||||||
NOTE |
Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
||||||
Arrow.com | File Name:PWM-200-SPEC 2024-09-09 |
DIMMING OPERATION
Dimming principle for PWM style output
Dimming is achieved by varying the duty cycle of the output current.
3 in 1 dimming function (for Blank-Type)‧
- Apply one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
- Dimming source current from power supply: 100μA (typ.)
Applying additive resistance:
Note :
- Min. duty cycle of output current is about 1%, and the dimming input is about 6KΩ or 0.6VDC, or 10V PWM signal with 6% duty cycle.
- The duty cycle of output current could drop down to 0% when dimming input is less than 6KΩ or less than 0.6VDC, or 10V PWM signal with duty cycle less than 6%
DALI interface PUSH dimming(primary side)
Action | Action duration | Function |
Short push | 0.1~1 sec. | Turn ON-OFF the driver |
Long push | 1.5~10 sec. | Every Long Push changes the dimming direction, dimming up or down |
Reset | >11 sec. | Set up the dimming level to 100% |
- The factory default dimming level is at 100%.
- If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver.
- Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button.
- The maximum length of the cable from the push button to the last driver is 20 meters.
- The additive push button can be connected only between the DA+ terminal, as displayed in the diagram, and AC/L (in brown or black); it will lead to short circuit if it is connected to AC/N.
DALI Interface (for DA2-Type)
- Apply DALI signal between DA+ and DA-.
- DALI protocol comprises 16 groups and 64 addresses.
- Min.duty cycle of output current is about 0.2%
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
EFFICIENCY vs LOAD
PWM-200 series possess superior working efficiency that up to 94% can be reached in field applications.
48V Model, Tcase at 75℃
LIFE TIME
Block Diagram
Mechanical Specification
Recommend Mounting Direction
Installation Manual
Connection for Blank-type and DA2-type
Cautions
- Before commencing any installation or maintenance work, please disconnect the power supply from the utility. Ensure that it cannot be re-connected inadvertently!
- Keep proper ventilation around the unit and do not stack any object on it. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
- Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current.
- Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer to its specification.
- For LED drivers with waterproof connectors, verify that the linkage between the unit and the lighting fixture is tight so that water cannot intrude into the system.
- For dimmable LED drivers, make sure that your dimming controller is capable of driving these units.PWM series require 0.15mA each unit.
- Tc max. is identified on the product label. Please make sure that temperature of Tc point will not exceed limit.
- Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.