1 GENERAL INFORMATION

Documentation for the LOGICisp D Collision Sensor consists of this Operating Manual and several other documents (Other applicable documents, page 5). Assembly personnel must read all documentation before starting assembly. Keep all documentation for as long as the product is in your possession. Ensure that all documentation is provided to subsequent owners. Go to www.logicdata.net for more information and support. This Manual may change without notice. The most recent version is available on our website.

1.1 OTHER APPLICABLE DOCUMENTS

This Operating Manual contains assembly and operation instructions for the LOGICisp D Collision Sensor.
Other applicable documents include:

  • Datasheet for LOGICisp D Collision Sensor.
  • DYNAMIC MOTION System Manual.
  • Datasheet and Operating Manual for the installed DYNAMIC MOTION Actuator.
  • Datasheet for installed Power Hub.
1.2 COPYRIGHT

© July 2024 by LOGICDATA Electronic und Software Entwicklungs GmbH. All rights reserved, except for those listed in Chapter 1.3 Royalty-free use of images and text on page 5.

1.3 ROYALTY-FREE USE OF IMAGES AND TEXT

After purchase and full payment of the product, all text and images in Chapter 2 “Safety”, may be used free of charge by the customer for 10 years after delivery. They should be used to prepare end user documentation for Height-Adjustable Table Systems. The license does not include logos, designs, and page layout elements belonging to LOGICDATA. The Reseller may make any necessary changes to the text and images to adapt them for the purpose of end user documentation. Texts and images may not be sold in their current state and may not be published or sublicensed digitally. The transfer of this license to third parties without permission from LOGICDATA is excluded. Full ownership and copyright of the text and graphics remain with LOGICDATA. Texts and graphics are offered in their current state without warranty or promise of any kind. Contact LOGICDATA to obtain text or images in an editable format (documentation@logicdata.net).

1.4 TRADEMARKS

Documentation may include the representation of registered trademarks of goods or services, as well as information about copyright or other proprietary expertise of LOGICDATA or third parties. In all cases, all rights remain exclusively with the respective copyright holder. LOGICDATA® is a registered trademark of LOGICDATA Electronic & Software GmbH in the USA, the European Union, and other countries.

2 SAFETY

2.1 TARGET AUDIENCE

This Operating Manual is intended for Skilled Persons only. Refer to Chapter 2.8 Skilled Persons on page 9 to ensure that personnel meet all requirements.

2.2 GENERAL SAFETY REGULATIONS

In general, the following safety regulations and obligations apply when handling the product:

  • Do not operate the product unless it is in a clean and perfect condition.
  • Do not remove, change, bridge, or bypass any protection, safety, or monitoring equipment.
  • Do not convert or modify any components without written approval from LOGICDATA.
  • In the event of malfunction or damage, faulty components must be replaced immediately.
  • Unauthorized repairs are prohibited.
  • Do not attempt to replace hardware unless the product is in a de-energized state.
  • Only Skilled Persons are allowed to work with LOGICisp D Collision Sensors.
  • Ensure that national worker protection conditions and national safety and accident prevention regulations are observed during operation of the System.
2.3 INTENDED USE

LOGICisp D is a Gyro Collision Sensor for electrically Height-Adjustable Tables. It is installed by Resellers into Height-Adjustable Table Systems. It is used to recognize collisions between the Table System and other objects. It is intended for indoor use only. It may only be installed in compatible Height-Adjustable Table Systems and with LOGICDATA-approved accessories. Contact LOGICDATA for further details. Usage beyond or outside the intended use will void the product’s warranty.

2.4 REASONABLY FORESEEABLE MISUSE

Usage outside of the intended use may lead to minor injury, serious injury, or even death. Reasonably foreseeable misuse of the Collision Sensor includes, but does not extend to:

  • Connecting unauthorized parts to the product. If you are unsure as to whether a part can be used with a Collision Sensor, contact LOGICDATA for further information.

Warning Icon 202 DANGER

The dedicated sockets on the Power Hub may only be used to accommodate LOGICDATA approved components. Connecting other equipment to these terminals may cause damage to the Power Hub, LOGICisp D or other products in the System.


2.5 EXPLANATION OF SYMBOLS AND SIGNAL WORDS

Safety Notices contain both symbols and signal words. The signal word indicates the severity of the hazard.


Warning Icon 202 DANGER

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.



Warning Icon 202 WARNING

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.



Warning Icon 202 CAUTION

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.



NOTICE Icon a18 NOTICE

Indicates a situation which, if not avoided, could result in damage to the product through electrostatic discharge (ESD).



NOTICE

Indicates a situation that will not lead to personal injury, but could lead to damage to the device or the environment.



Class III icon a3 INFO

Indicates the protection class of the device: Protection Class III.
Protection Class III devices may only be connected to SELV or PELV power sources.



INFO

Indicates important tips for handling the product.


2.6 LIABILITY

LOGICDATA products comply with all currently applicable health and safety regulations. However, risk can result from incorrect operation or misuse. LOGICDATA is not liable for damage or injury caused by:

  • Improper product use.
  • Disregard of the documentation.
  • Unauthorized product alterations.
  • Improper work on and with the product.
  • Operation of damaged products.
  • Wear parts
  • Improperly performed repairs.
  • Unauthorized changes to the operating parameters.
  • Disasters, external influence, and force majeure

The information in this Operating Manual describes the characteristics of the product without assurances. Resellers assume responsibility for the LOGICDATA products installed in their applications. They must ensure their product complies with all relevant directives, standards, and laws. LOGICDATA shall not be held liable for any damage that is directly or indirectly caused by the delivery or use of this document. Resellers must observe the relevant safety standards and guidelines for each product in the Table System.

2.7 RESIDUAL RISKS

Residual risks are the risks that remain after all relevant safety standards have been complied with. Residual risks associated with the installation of the lOGICisp D are listed here and throughout this Operating Manual. See also Chapter 1.1 Other Applicable Documents on page 5. The symbols and signal words used in this Operating Manual are listed in Chapter 2.5 Explanation of Symbols and Signal Words on page 7.


Warning Icon 202 WARNING

Risk of death or serious injury through electric shocks
LOGICisp D Collision Sensor is a protection CLASS III device. Although you will not have to connect any products to the Power Hub during assembly, basic safety precautions must be taken at all times. Failure to observe electrical safety precautions may lead to death or serious injury through electric shocks.

  • Do not convert or modify the Collision Sensor in any way.
  • Do not immerse the Collision Sensor or its components in liquid. Clean only with a dry or slightly damp cloth.
  • Check the housing of the Collision Sensor for visible damage. Do not install or operate damaged products.


Warning Icon 202 WARNING

Risk of death or serious injury in explosive atmospheres
Operating the Collision Sensor in potentially explosive atmospheres may lead to death or serious injury through explosions.

  • Do not operate the Handset in potentially explosive atmospheres.


Warning Icon 202 CAUTION

Risk of minor or moderate injury through crushing
The LOGICisp D is not intended as a user safety device. Failure to observe basic safety precautions may lead to minor or moderate injury through crushing.

  • Keep all body parts away from the Table‘s range of motion while it is moving.
  • Ensure the Table‘s range of motion is free from obstructions (open windows, etc.)

2.8 SKILLED PERSONS

LOGICisp D may only be installed by Skilled Persons. A Skilled Person is defined as someone who:

  • Has read and understood all documentation relevant to the Collision Sensor.
2.9 NOTES FOR RESELLERS

Resellers are companies that purchase LOGICDATA products for installation in their own products.


INFO

For reasons of EU conformity and product safety, Resellers should provide end users with an Operating Manual in their native EU official language.



INFO

The Charter of the French Language (La charte de la langue française) or Bill 101 (Loi 101) guarantees the right of the population of Quebec to conduct business and commercial activities in French. The bill applies to all products sold and used in Quebec. For Table Systems that will be sold or used in Quebec, Resellers must provide all product relevant texts in French. These include, but are not limited to:

  • Operating Manuals
  • All other product documentation, including datasheets.
  • Inscriptions on the product (such as labels), including those on product packaging.
  • Warranty certificates

The French inscription may be accompanied with a translation or translations, but no inscription in another language may be given greater prominence than that in French.



INFO

Operating Manuals must include all the safety instructions that end users require to handle the product safely. They must also include an instruction to always keep the Operating Manual in the immediate vicinity of the product.



INFO

No unauthorized persons (young children, persons under the influence of medications, etc.) should be allowed to handle the product.


3 SCOPE OF DELIVERY

The standard scope of delivery for the LOGICisp D consists of the Collision Sensor. All other components necessary for installing the Collision Sensor must be supplied separately by the reseller.

4 UNPACKAGING

To unpackage the product:

  1. Remove all components from the packaging.
  2. Check the contents of the package for completeness and damage.
  3. Provide the Operating Manual to the operating personnel.
  4. Dispose of the packaging material.

NOTICE

Dispose of the packaging material in an environmentally friendly manner. Remember to separate plastic parts from the cardboard packaging.



NOTICE Icon a18 NOTICE

Ensure proper ESD handling during unpackaging. Damage that can be attributed to electrostatic discharge will void warranty claims.


5 PRODUCT

Fig.1 shows a standard model of the LOGICisp D Collision Sensor. The exact variant of the LOGICisp D is denoted by the product`s order code. Consult the accompanying data sheet to ensure that you have received the correct variant.

5.1 ABOUT INTELLIGENT SYSTEM PROTECTION

Intelligent System Protection (ISP) is LOGICDATA’s collision detection System. It aims to reduce the risk of System damage when using LOGICDATA products. When a collision is detected, all Actuators stop immediately and move back slightly in the opposite direction (Drive Back Function). The following points must be observed regarding the ISP function.

  • ISP sensitivity and ISP shutdown values depend on the complete System (mechanical and electronic components). Contact LOGICDATA to determine the ISP suitability of your Table System.
  • After ISP has shutdown, the next movement of the System can only be in the opposite direction.
  • ISP shutdown values can be adjusted in the System parameters. Contact LOGICDATA for further details.
5.2 KEY PRODUCT FEATURES

LOGICisp D Collision Sensor is connected directly to Power Hub.

1 Collision Sensor
2 Connector (for connecting LOGICisp D to Power Hub)

LOGICDATA LOGICisp D Collision Sensor - Fig. 1

Fig. 1: Product features LOGICisp D

5.3 DIMENSIONS LOGICISP D
Length 80,1 mm | 3.15”
Width 14,3 mm | 0.56”
Height 19,4 mm | 0.76”

LOGICDATA LOGICisp D Collision Sensor - Fig. 2

Fig. 2: Product dimensions LOGICisp D

6 ASSEMBLY

This chapter describes the process of installing the LOGICisp D Collision Sensor into the Height Adjustable Table System.

6.1 SAFETY DURING ASSEMBLY

Warning Icon 202 CAUTION

Risk of death or serious injury through electric shocks
LOGICisp D Collision Sensors are electrical devices. Basic safety precautions must be taken at all times. Failure to observe electrical safety precautions may lead to death or serious injury through electric shocks.

  • Ensure that the Collision Sensor is not connected to the Power Hub during assembly.
  • Do not convert or modify the Collision Sensor in any way.
  • Check the Collision Sensor and its Cables for visible damage. Do not install or operate damaged products.


Warning Icon 202 CAUTION

Risk of minor or moderate injury through improper handling
Improper handling of the product during assembly may lead to minor or moderate injury through cutting, pinching, and crushing.

  • Avoid contact with sharp edges.
  • Be careful while handling tools that may cause personal injury.
  • Ensure assembly complies with the generally accepted standards and guidelines of electrical engineering and furniture manufacturing.
  • Read all instructions and safety advice carefully.


NOTICE Icon a18 NOTICE

Ensure proper ESD handling during assembly. Damage that can be attributed to electrostatic discharge will void warranty claims.



NOTICE

To avoid damage to the product, measure the dimensions of the Collision Sensor before assembly.



NOTICE

Before assembly, all parts must be acclimatised to the ambient conditions.


6.2 REQUIRED COMPONENTS
1 LOGICisp D
6.3 NOTES FOR ASSEMBLY

The LOGICisp D is plugged into Power Hub which is assembled on to the bottom of the Table Top. It shall be placed near the middle of the Table.


NOTICE

If Collision Sensor is mounted incorrectly, Intelligent System Protection may not work properly. This could be lead to damage to the Table System.



NOTICE

Connecting the External Collision Sensor to other devices or Plug Ports, including external telecommunication ports, may damage the Sensor irreparably. Contact LOGICDATA if you are unsure whether the External Collision Sensor is compatible with your device.



INFO

Exact dimensions for your Collision Sensor can be found in the product`s datasheet.


LOGICDATA LOGICisp D Collision Sensor - Fig. 3

Fig. 3: Mounting the LOGICisp D to a 2-leg table system

LOGICDATA LOGICisp D Collision Sensor - Fig. 4

Fig. 4: Mounting the LOGICisp D to a 3-leg table system

6.4 PROCESS

Plug in LOGICisp D sensor into one of the free connectors on the Power Hub.

6.5 CONNECTING TO THE SYSTEM
6.5.1 CONNECTING TO A POWER HUB

NOTICE

The LOGICisp D shall be placed in the middle of the Table as shown in Fig. 3 and 4.



NOTICE

The connector sockets on the Power Hub may only be used to accommodate LOGICDATA approved electronic devices. Inserting any other electronic devices into the socket may cause damage to the Power Hub or other products in the System.


INFO

If your System is not parametrized to support Intelligent System Protection, you will need to alter the parameters so that the LOGICDATAisp D Collision Sensor functions correctly. Contact LOGICDATA for further advice on System parameters.


  1. Ensure the Power Hub is not connected to the power source.
  2. Insert LOGICisp D sensor into one of free ports on the Power Hub.
  3. Reconnect the Power Hub to the power source.

LOGICDATA LOGICisp D Collision Sensor - Fig. 5

Fig. 5: Attaching LOGICisp D to Power Hub

7 SYSTEM INFORMATION

7.1 MESSAGES SHOWN ON A COMPATIBLE HANDSET WITH DISPLAY
LOGICDATA LOGICisp D Collision Sensor - 1 ISP Activated Release all Keys and wait for the Drive Back functions to be completed.
LOGICDATA LOGICisp D Collision Sensor - 2 Collision Sensor Defective or not connected Check if the sensor is properly connected to the System. Contact LOGICDATA if the problem persists.

8 ADDITIONAL INFORMATION

8.1 SOFTWARE-DEPENDENT FUNCTIONS

A full list of Software-Dependent Functions can be found in other applicable documents listed in Chapter 1.1 of this document.

8.2 DISASSEMBLY

To disassemble the LOGICisp D, disconnect the Power Hub from the power source. Then, follow the assembly instructions in reverse order.

8.3 MAINTENANCE

LOGICisp D Collision Sensor is maintenance-free for their entire service lifetime.


Warning Icon 202 WARNING

Risk of death or serious injury through electric shocks and other hazards
Using a Collision Sensor alongside unauthorized spare or accessory parts may lead to death or serious injury through electric shocks and other hazards.

  • Only use accessory parts produced or approved by LOGICDATA.
  • Only use replacement parts produced or approved by LOGICDATA.
  • Only allow Skilled Persons to perform repairs or install accessory parts.
  • Contact customer services immediately if the System malfunctions.

The use of unauthorized spare or accessory parts may cause System damage.
Warranty claims are void in this scenario.


8.3.1 CLEANING
  1. Wait 30 seconds for residual voltage to dissipate.
  2. Wipe the Collision Sensor with a dry cloth. Never immerse the Collision Sensor in liquid.
  3. Wait for the Collision Sensor to dry completely.
8.3.2 REPLACING A COLLISION SENS
  1. Disconnect the Power Hub from Mains.
  2. Disconnect the Collision Sensor from the Power Hub.
  3. Plug in the new Collision Sensor into Power Hub.
  4. Connect the Power Hub to the Mains.
8.4 TROUBLESHOOTING

A list common problems and their solutions can be found in other applicable documents listed in Chapter 1.1 of this document.

8.5 DISPOSAL

Disposal Icon 75 Dispose of all components separately from household waste. Use designated collection points or disposal companies authorized for this purpose.

LOGICDATA logo

LOGICDATA
Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria

Phone: +43 (0)3462 5198 0
Fax: +43 (0)3462 5198 1030
E-mail: office.at@logicdata.net

LOGICDATA North America, Inc.
13617 Woodlawn Hills Dr.
Cedar Springs, MI 49319
USA

Phone: +1 (616) 328 8841
E-mail: office.na@logicdata.net

LOGICDATA A - 2 www.logicdata.net

Documents / Resources

LOGICDATA LOGICisp D Collision Sensor [pdf] Instruction Manual
LOGICisp D Collision Sensor, LOGICisp, D Collision Sensor, Collision Sensor, Sensor

References

Leave a comment

Your email address will not be published. Required fields are marked *