Alur-logo

Aliran com ABC-2020 Otomatis Batch Controller

 

Flows-com-ABC-2020-Otomatis-Batch-Controller-produk

Isi Box
Kontrol Batch Otomatis ABC

Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-1

  • Kabel Daya - 12 VDC Standard US Wall Plug TransformerFlows-com-ABC-2020-Otomatis-Batch-Controller-anjir-2
  • Kit sing dipasangFlows-com-ABC-2020-Otomatis-Batch-Controller-anjir-3

Kontrol Batch Otomatis

Fitur Fisik - Ngarep View

Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-4

Sambungan kabel - mburi View

Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-5

Cathetan: yen nggunakake relay pump, ing panggonan katup, sing kontrol kabel sinyal menyang port labeled "katup".

Pedoman Persiyapan lan Instalasi

ABC Automatic Batch Controller dirancang kanggo digunakake karo meter apa wae sing duwe switch output pulsa utawa sinyal. Iki ndadekake controller banget serbaguna lan ngidini akeh persiyapan instalasi. Cara nyetel utawa nginstal gumantung saka akeh faktor. Kanggo informasi luwih lengkap lan instalasi lan exampkaro ilustrasi lan video, bukak: https://www.flows.com/ABC-install/

Pedoman Umum

  1. Priksa manawa arah aliran ngetutake panah ing katup, pompa, lan meter. Umume meter bakal duwe panah sing dicithak ing sisih awak. Padha uga biasane duwe strainer ing inlet. Katup lan pompa uga bakal duwe panah nalika arah aliran penting. Ora masalah kanggo katup bal port lengkap.
  2. Disaranake sampeyan nyelehake tutup sawise meter lan cedhak karo stopkontak pungkasan. Yen sampeyan nggunakake pompa ing panggonan katup, dianjurake supaya pompa diselehake sadurunge meter.

Katup & Meter
kanggo Water City, Tank Bertekanan, utawa Sistem Feed GravitasiFlows-com-ABC-2020-Otomatis-Batch-Controller-anjir-6

Pompa & Meter
kanggo Tank Non-Pressurized, utawa ReservoirFlows-com-ABC-2020-Otomatis-Batch-Controller-anjir-7

  1. Yen nggunakake meter multi-jet (kaya meter banyu kluwarga khas: WM kita, WM-PC, WM-NLC) iku penting sing meter horisontal, tingkat, lan register (pasuryan tampilan) madhep langsung munggah. Sembarang variasi saka iki bakal nggawe meter kurang akurat amarga mekanika lan prinsip kerja. Deleng aksesoris sing nggawe iki gampang ing kaca 8.Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-8
  2. 4. Produsen meter biasane nyaranake dawa pipa lurus sadurunge lan sawise meter. Nilai kasebut biasane ditulis ing pirang-pirang ID pipa (diameter njero). Sing ngidini nilai kasebut tetep bener kanggo ukuran pirang-pirang meter. Ora netepi nilai kasebut bisa mengaruhi akurasi meter. Pengulangan meter kudu tetep ok sanajan akurasi ora aktif, mula pangaturan bisa ditindakake kanthi ngganti nilai sing disetel kanggo ngimbangi.
  3. Pasang controller kumpulan kaya sing dikarepake. ABC-2020 dilengkapi kit kanggo masang controller menyang tembok utawa pipa kaya sing dituduhake ing kene.Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-9
  4. Sawise Batch Controller dipasang, sambungake kabeh kabel kalebu daya, meter, lan katup utawa pompa. Yen nggunakake tombol remot, sambungake uga. Label port dicithak kanthi cetha lan langsung ing ndhuwur saben port. Yen sampeyan tuku ABC diinstal ing ABC-NEMA-BOX lan ora bisa maca label ing ndhuwur bandar, sampeyan bisa deleng ilustrasi ing kaca 2 kanggo ndeleng apa bandar.
  5. Pasang saklar output pulsa lan kabel ing meter. Yen sampeyan tuku meter saka Flows.com nganggo pengontrol, saklar kasebut wis dipasang. Yen sampeyan tuku meter ing wektu mengko, utawa saka sumber liyane, tindakake pandhuan sing kasedhiya karo meter.
    Cathetan: output pulsa kudu jinis nutup kontak! Meter karo voltagoutput pulsa e-jinis mbutuhake nggunakake Konverter Pulse. Hubungi Flows.com kanggo ndeleng apa meter tartamtu bakal bisa digunakake karo ABC. Yen kabel ora duwe konektor sing tepat ing mburi, sampeyan bisa tuku kabel / konektor kit saka Flows.com.
    • Nomer bagean: ABC-WIRE-2PC
  6. Dianjurake supaya bonggol diselehake ing cedhak stopkontak. Nalika nggunakake pompa, iki njamin meter bakal tetep kebak ing antarane batch sing dikarepake kanggo umur meter lan akurasi. Malah nalika nggunakake katup iki bisa migunani kanggo ngindhari dribble dawa yen tutup wis ditutup.
  7. PENTING: Sawise meter lan katup utawa pompa wis diinstal lan sampeyan siyap kanggo dispense kumpulan pisanan, sampeyan kudu mbukak sawetara kelompok cilik. Iki bakal miwiti sistem kanthi ngresiki hawa sing ana lan nyetel dial meter (ing meter mekanik) menyang titik wiwitan sing tepat. Iku uga bakal ngesyahke yen meter bisa digunakake lan saklar output pulsa lan kabel wis diinstal kanthi bener. Proses iki uga bisa digunakake kanggo nyetel setelan sampeyan babagan carane cairan metu saka stopkontak lan mlebu ing wadhah panampa. Tambahan, kumpulan iki bisa digunakake kanggo mriksa pinten ekstra liwat ing mburi kumpulan.
    • ABC-2020-RSP: anggere unit pulsa lengkap ora ngliwati batch sampeyan bakal akurat. Sembarang unit sebagean dijupuk saka kumpulan sabanjure sing bakal entuk jumlah kasebut ing pungkasan - kanthi efektif mbatalake.
    • ABC-2020-HSP: Tampilan ing controller bakal ngrekam lan nampilake kabeh jumlah total sing liwat meter preduli saka apa kumpulan wis disetel kanggo. Nggunakake nomer kasebut sampeyan bisa nyuda jumlah set kumpulan lan entuk nilai sing cocog kanggo nyetel "Overage" ing setelan kasebut.

Operasi

Sawise sampeyan duwe kabel daya, meter, lan katup (utawa relay pompa) disambungake menyang pengontrol ABC, operasi kasebut cukup prasaja.

PENTING: Waca Pedoman Persiyapan #9 ing kaca sadurunge sadurunge dispensing kumpulan kritis.

Langkah 1: Nguripake controller nggunakake ngalih daya ngusapake. Konfirmasi manawa pengontrol nduweni program sing bener dimuat kanggo meter sing sampeyan gunakake sing ditampilake sedetik ing layar pambuka. Yen sampeyan tuku controller iki minangka bagéan saka sistem lengkap, bakal kabeh setelan sing bener kanggo K-faktor utawa Nilai pulsa lan Unit ukuran kanggo cocog meter sing teka karo sistem.

ABC-2020-RSP yaiku kanggo meter kanthi nilai pulsa sing genap. jinis iki sing ditawakake Flows.com kalebu:

  • Multi-jet Water Meter (kudu dipasang kanthi horisontal kanthi pasuryan munggah)
  • WM-PC, WM-NLC, WM-NLCH Positive Displacement Water Meter (jinis disk nuting)
  • D10 Magnetik Induktif lan Ultrasonik Meter
  • MAG, MAGX, FD-R, FD-H, FD-X Meter iki duwe vol aktiftagSinyal pulsa e, mbutuhake konverter pulsa ABC-PULSE-CONV sing uga menehi daya kanggo meter. Meter kasebut duwe volume sing bisa disetel saben pulsa.

ABC-2020-HSP kanggo meter karo K-faktor

Meter iki duwe output pulsa ing ngendi ana akeh pulsa saben unit ukuran kayata 7116 saben galon, 72 saben galon, 1880 saben liter, lan liya-liyane. Meter saka jinis iki sing ditawakake Flows.com kalebu:

Oval Gear Positif pamindahan

  • OM
    Turbin Meter Kab
  • TPO
    Paddle Wheel Meter
  • WM-PT
  • Langkah 2: Gunakake tombol kiwa lan tengen kanggo nyetel volume sing dikarepake.Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-10
  • Langkah 3: Sawise nilai sing dikarepake disetel, pencet tombol Big Blinking Blue Button™ kanggo miwiti kumpulan. Nalika batch lagi dispensing, tombol Big Blinking Blue Button™ bakal kedhip sapisan saben detik.
  • Langkah 4: Sampeyan saiki bisa milih mode tampilan sing disenengi nggunakake tombol panah:Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-11

Sawise sampeyan menet tombol apa wae, tampilan bakal nuduhake mode tampilan sing dipilih. Sing bakal tetep nganti pulsa sabanjure ditampa saka meter. Sampeyan bisa ngganti mode tampilan sawayah-wayah nalika kumpulan lagi mlaku. Nilai iki bakal disimpen kanthi permanen.

Mode Tampilan

  • Tingkat aliran ing Unit saben Menit - iki mung ngetung tarif adhedhasar wektu iku njupuk kanggo unit pungkasan kanggo dispensed.
  • Bar Kemajuan – Nampilake garis ngalangi prasaja sing tuwuh saka kiwa menyang tengen.
  • Persen Rampung - Nuduhake persentage saka total sing wis dispensed
  • Kira-kira Wektu Sisa – Mode iki njupuk wektu liwati sak unit pungkasan lan multiplies dening nomer Unit isih.

Langkah 5: Nalika kumpulan mlaku, tonton Big Blinking Blue Button™. Nalika batch wis rampung 90%, kedhip bakal luwih cepet nuduhake yen batch wis meh rampung. Yen kumpulan wis rampung, katup bakal nutup utawa pompa bakal mati lan Big Blinking Blue Button™ bakal tetep murup.

Ngaso utawa mbatalake Batch
Nalika kumpulan lagi mlaku, sampeyan bisa mungkasi sawayah-wayah kanthi menet Big Blinking Blue Button™. Iki bakal ngaso batch kanthi nutup tutup utawa mateni pompa. Tombol Biru Big Blinking ™ uga bakal mati. Ana 3 pilihan apa sing kudu ditindakake sabanjure:

  1. Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-12Pencet Big Blinking Blue Button™ kanggo RESUME batch
  2. Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-13Pencet tombol panah kiwa adoh kanggo STOP kumpulan
  3. Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-14Pencet tombol panah sisih tengen kanggo RESET meter menyang negara wiwitan (ABC-2020-RSP mung). Iki tegese sistem bakal dispense sisa unit pulsa saiki; 1/10, 1, utawa 10. Wektu entek: (ABC-2020-RSP mung)

Ana nilai wektu entek sing bisa disetel supaya yen controller ora nampa pulsa kanggo nomer X detik, bakal ngaso kumpulan. Iki bisa disetel saka 1 nganti 250 detik, utawa 0 kanggo mateni fungsi kasebut. Tujuan saka fungsi iki kanggo nyegah kebanjiran ing kasus sing meter mandheg sesambungan karo controller. Indikasi Status: Status sistem terus-terusan dituduhake dening Big Blinking Blue Button™.Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-15

Indikasi status kasebut yaiku:

  • Solid On = Setel volume – Sistem siap
  • Kedhip-kedhip Sepisan Per Detik = Sistem dispensing batch
  • Kedhip-kedhip Cepet = Dispensing 10% pungkasan saka kumpulan
  • Kedhip-kedhip Cepet banget = wektu entek
  • Mati = Batch wis ngaso

Setelan
Preduli saka program kang controller ABC, sampeyan ngetik mode setelan ing cara sing padha. Nalika controller siyap kanggo dispense kumpulan ing mode "volume nyetel", mung pencet loro panah njaba bebarengan.Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-16

Sawise ing mode setelan, sampeyan bakal dijupuk liwat urutan setelan. saben diganti nggunakake panah lan nyetel nggunakake Big Blinking Blue Button™. Sawise sampeyan nggawe setelan, controller konfirmasi apa sing disetel banjur maju menyang sabanjure. Urutan setelan lan katrangan babagan apa sing ditindakake rada beda kanggo rong program sing beda.

ABC-2020-RSP (kanggo meter kanthi nilai pulsa sing rata)

NILAI PULSA
Iki mung jumlah cairan sing diwakili dening saben pulsa. Nilai sing bisa ditindakake yaiku: 0.05, 0.1, 0.5, 1, 5, 10, 50, 100 Ing meter mekanik iki ora bisa diganti ing lapangan. Ing meter digital iki bisa diganti.

UNIT UKURAN
Mung label supaya sampeyan ngerti apa unit sing digunakake. Nilai sing bisa ditindakake yaiku: Galon, Liter, Kaki Kubik, Meter Kubik, Pound

TIMEOUT
Jumlah detik saka 1 nganti 250 sing bisa ditindakake tanpa pulsa sadurunge ngaso batch kasebut. 0 = dipatèni.

LOCKOUT

  • On = sampeyan kudu mencet tombol panah ing controller sadurunge sampeyan bisa miwiti kumpulan. Tombol remot ora bakal bisa miwiti batch nganti rampung.
  • Mati = sampeyan bisa mbukak batch Unlimited kanthi mencet tombol remot.
  • ABC-2020-HSP (kanggo meter karo K-faktor)

K-FAKTOR
Iki nggambarake "pulsa saben unit" sing bisa diatur kanggo akurasi sing luwih apik yen meter dipasang ing aplikasi sing nyata.

UNIT UKURAN (padha karo ndhuwur)

RESOLUSI
Pilih 10ths utawa kabèh unit.

OVERAGE
Sawise sampeyan ngerti sepira volume ekstra sing dilewati ing pungkasan batch, sampeyan bisa nyetel iki supaya controller mandheg luwih awal kanggo mlebu ing target.

Ngatasi masalah

Sistem batching dispensing akeh banget.
Pisanan, priksa manawa meter dipasang ing arah lan orientasi sing tepat. Meter sing dipasang mundur bakal kurang, mula sistem bakal over-dispense. Sampeyan bisa uga ngluwihi tingkat pulsa maksimal. Kanggo nggunakake katup solenoid, utawa katup tumindak cepet liyane, disaranake sampeyan ora ngluwihi siji pulsa per detik (sanajan nganti rong per detik kudu apik). Kanggo nggunakake tutup bal EBV, disaranake sampeyan ora ngluwihi siji pulsa saben 5 detik. Yen sampeyan nyatane ngluwihi tingkat pulsa, atur tingkat aliran kanggo ndandani utawa nimbang jinis katup sing beda utawa program pengontrol kumpulan lan meter kanthi tingkat pulsa sing beda. Nalika nggunakake meter multi-jet kita, sampeyan kudu nggawe manawa kurang saka siji unit lengkap dispensed sawise tutup wiwit nutup. Nalika misale jek kaya sembarang overage bakal mengaruhi akurasi kumpulan, iku penting kanggo elinga yen sembarang overage ing kumpulan sing mbukak bakal dikurangi saka unit pisanan saka kumpulan sabanjuré. Iki èfèktif cancels metu overage ing pungkasan. Yen luwih saka unit kebak liwat… unit lengkap ora bakal dikurangi.

Batch diwiwiti, nanging ora ana unit sing diitung.
Switch output pulsa lan kabel ora diinstal kanthi bener. Priksa manawa saklar ditempelake ing pasuryan meter lan dicekel kanthi kuat dening sekrup cilik. Uga, priksa manawa ujung kabel liyane wis dipasang kanthi bener lan rampung menyang pengontrol. Pungkasan, priksa kabel kasebut lan priksa manawa ora ana karusakan ing insulasi njaba lan loro ujung kabel katon nyambung menyang saklar lan konektor.

Cathetan: Saklar reed mekanik pungkasane bakal rusak. Saklar sing diwenehake Flows.com duwe pangarep-arep urip minimal 10 yuta siklus. Mulane, disaranake ora milih resolusi sing luwih apik tinimbang sing dibutuhake. Umpamane: yen dispensing 1000 galon, sampeyan ora pengin nganggo 10 galon. Sampeyan bakal luwih apik milih pulsa 10 galon. Sing bakal dadi 100 kaping kurang siklus kanggo ngalih.

Batcher terus diwiwiti lan mandheg.
Priksa manawa Big Blinking Blue Button™ ora macet ing kahanan depresi. Yen sampeyan nggunakake tombol remot, priksa uga. Yen sampeyan ora nggunakake tombol remot, mriksa port sambungan ing mburi controller lan priksa manawa ora ana shorting metu samubarang pin. Yen kabeh mriksa metu OK, sampeyan bisa uga wis nandang gerah banyu ing salah siji tombol utawa nang controller. Copot kabeh lan supaya unit garing sak tenane. Sampeyan bisa nyelehake ing wadhah kanthi desiccant utawa beras garing kanggo dina.

Katup mbukak utawa pompa diwiwiti sanalika controller diuripake.
Saklar sing ngontrol katup wis dadi ala. Ngalih iki over-rated kanggo nggunakake klep sing disaranake, nanging shorting metu sirkuit kanggo tutup bisa ngrusak switch. Sampeyan kudu ngganti controller. Yen controller ana ing babar pisan (setaun saka wektu tuku) hubungi Flows.com kanggo njaluk Return Merchandise Wewenang.

Katup ora tau mbukak, utawa pompa ora diwiwiti.
Priksa kabeh kabel saka controller menyang katup utawa relay pompa. Iki kalebu sambungan ing ujung loro, uga dawa kabeh kabel. Yen Big Blinking Blue Button™ kedhip, banjur tutup kudu mbukak, utawa pompa kudu urip.

Aksesoris

Meter
ABC Batch Controller dianggo karo sembarang meter sing duwe sinyal output pulsa utawa ngalih. Flows.com nawakake macem-macem meter sing cocog karo aplikasi sampeyan. Sing paling umum yaiku saka Assured Automation.

Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-17

Katup
Kontroler Batch ABC bisa digunakake karo katup apa wae sing bisa diaktifake kanthi nggunakake catu daya utawa sinyal kontrol 12 VDC nganti 2.5 Amps. Iki kalebu katup pneumatik sing dikontrol dening katup solenoid 12 VDC.Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-18

120 VAC Power Relay kanggo Pump Control

Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-19

Kontrol sumber daya iki duwe loro stopkontak biasane Off sing diuripake dening sinyal 12 VDC sing dikirim saka controller. Iki ngidini kanggo nggunakake sembarang pump utawa katup sing makaryakke nggunakake 120 VAC plug stopkontak standar US.

Tombol Remote Tahan Cuaca

Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-20

Tombol remot iki tumindak minangka tiron saka Big Blinking Blue Button™ ing unit kasebut. Padha nindakake persis padha ing kabeh wektu.

Nomer bagean: ABC-PUMP-RELAY

Nomer Bagian:

  • Kabel: ABC-REM-NANGING-WP
  • Nirkabel: ABC-WIRELESS-REM-Nanging

Kothak Cuaca (NEMA 4X)

Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-21

Pasang Kontroler Batch ABC ing kasus tahan cuaca iki kanggo digunakake ing njaba ruangan utawa ing lingkungan sing wisuh. Kothak kasebut nduweni tutup ngarep sing bening lan engsel sing ditutup kanthi aman kanthi 2 kancing flip stainless steel. Kabeh perimeter nduweni segel sing terus-terusan diwutahake kanggo pangayoman mutlak saka unsur. Kabel metu liwat kelenjar kabel PG19 sing kontrak watara kabel nalika nut wis tightened. Kabeh kothak weatherproof dilengkapi kit soyo tambah stainless steel kanggo instalasi gampang nggunakake fasteners ing kabeh 4 sudhut. Kothak bisa dituku kanthi kapisah, utawa kanthi dipasang Controller Batch ABC-2020.

Nomer bagean: ABC-NEMA-KOTAK

Konverter Pulsa

Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-22

Aksesori iki ngidini nggunakake seri MAG Magnetic Inductive Meter utawa meter apa wae sing nyedhiyakake voltage pulsa antarane 18 lan 30 VDC. Iku ngowahi voltage pulsa kanggo nutup kontak prasaja kaya sing saka ngalih reed digunakake ing meter mechanical kita.

Nomer bagean: ABC-PULSE-CONV

Garansi

JAMINAN PRODUSEN SATU TAHUN STANDAR: Pabrikan, Flows.com, njamin Controller Batch Otomatis ABC iki bebas saka cacat ing pengerjaan lan bahan, miturut panggunaan lan kahanan normal, sajrone siji (1) taun kanggo tanggal invoice asli. Yen sampeyan nemu masalah karo ABC Automatic Batch Controller, nelpon 1-855-871-6091 kanggo dhukungan lan njaluk wewenang bali.

Penafian

Kontrol Batch Otomatis iki kasedhiya tanpa jaminan utawa garansi liyane saka sing kasebut ing ndhuwur. Ing asosiasi karo batch con-troller, Flows.com, Assured Automation, lan Farrell Equipment & Controls ora nganggep tanggung jawab apa wae, kanthi nyata utawa diwenehake, kalebu nanging ora winates kanggo ciloko kanggo wong, kerusakan properti, utawa mundhut barang. . Panganggone produk dening pangguna ana ing risiko pangguna.Flows-com-ABC-2020-Otomatis-Batch-Controller-anjir-23

50 S. 8th Street Easton, PA 18045 1-855-871-6091 Dok. FDC-ABC-2023-11-15

Dokumen / Sumber Daya

Aliran com ABC-2020 Otomatis Batch Controller [pdf] Manual pangguna
ABC-2020, ABC-2020 Pengontrol Batch Otomatis, Pengontrol Batch Otomatis, Pengontrol Batch, Pengontrol

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *