ORACLE 17009 Microwave Sensor Module
Nkọwapụta
Koodu ngwaahịa | Ogologo | Obosara | Ogologo | Wattage | Voltage | Ogo IP | Ntụle IK | Mgbakọta Lumens | Okpomọkụ na-arụ ọrụ gburugburu | Angle Beam | Ibu |
---|---|---|---|---|---|---|---|---|---|---|---|
16897 | 4ft/1200mm | 61mm | 71mm | 20/26/30/37W | 220-240V 50/60Hz | IP20 | IK08 | 5500lm - 9300lm | Ambient | 120° | 1.25 KG – 1.9 KG |
16963 | 5ft/1500mm | 61mm | 71mm | 30/35/42/50W | 220-240V 50/60Hz | IP20 | IK08 | 7500lm | Ambient | 120° | 1.6KG |
16910 | 6ft/1800mm | 61mm | 71mm | 35/42/50/62W | 220-240V 50/60Hz | IP20 | IK08 | 9300lm | Ambient | 120° | 1.9KG |
Ntuziaka nwụnye
Use an appropreate ammount of fixtures to hold the unit weight
Nkwadebe
Prepare surface/mount ensure mount can hold the product weight
Open unit
Push in lock buttons on either end and open as indicated
Install Microwave Sensor
- C.1 Align with tabs
- C.2 Push until locked into position
Install Emergency Module
- D1 Align with tabs
- D.2 Turn locking tabs into locked position
- D.3 Open battery compartment
- D.4 Connect 3.2V LiFePO4 1W / 1500mA battery
- D.5 Close battery compartment
- D.6 Push out LED status light bung
For Manual test follow above testing guide, open cover for access.- D.7 6.1 Align LED status light
- 6.2 Push LED status light into place
Wiring + Connection Information
Wụnye ikpeazụ
G Emergency Indicator
Ikanam | Agba agba | Ọnọdụ |
ON | GREEN | Batrị dị mma |
ON / OFF / ON (0.25 sec) | GREEN | On / Off Test |
ON / OFF / ON (1 sec) | GREEN | Nnwale oge |
ON | Uhie | LED OR Power Issue |
ON / OFF / ON (0.25 sec) | Uhie | Low or Faulty Battery |
ON / OFF / ON (1 sec) | Uhie | Charge or Live Error |
Gbanyụọ | Uhie + GREEN | Switch Live or Live Error |
CCT Settings
Wattage Selection Settings
16897 – 4 FT Oracle Plus
Ike
(W) |
Mgbanwe Mgbanwe Ntọala
1 2 3 |
||
22 | — | — | ON |
27 | — | ON | — |
34 | ON | — | — |
40 | — | — | — |
16963 – 5 FT Oracle Plus
Ike
(W) |
Mgbanwe Mgbanwe Ntọala
1 2 3 |
||
30 | — | — | ON |
35 | — | ON | — |
42 | ON | — | — |
52 | — | — | — |
16910 – 6 FT Oracle Plus
Ike
(W) |
Mgbanwe Mgbanwe Ntọala
1 2 3 |
||
36 | — | — | ON |
42 | — | ON | — |
50 | ON | — | — |
63 | — | — | — |
Turn off power and open cover
Toggle Wattage selection dip switches to select output power
Ntọala ihe mmetụta Microwave
Mpaghara Nchọpụta
Oke | Mgbanwe Mgbanwe Ntọala
1 2 |
|
100% | ON | ON |
75% | ON | — |
50% | — | ON |
25% | — | — |
Ihe mmetụta ìhè ụbọchị
Ọkwa ọkụ | Mgbanwe Mgbanwe Ntọala
6 7 8 |
||
2 Lux | ON | ON | ON |
10 Lux | ON | ON | — |
25 Lux | — | ON | — |
50 Lux | ON | — | — |
Agbanyụrụ | — | — | — |
Jide oge
Oge | Mgbanwe Mgbanwe Ntọala
3 4 5 |
||
5 Sekọnd | ON | ON | ON |
30 Sekọnd | ON | ON | — |
Nkeji 1 | ON | — | ON |
Nkeji 3 | ON | — | — |
Nkeji 5 | — | ON | ON |
Nkeji 10 | — | ON | — |
Nkeji 20 | — | — | ON |
Nkeji 30 | — | — | — |
Turn off power and open cover
Toggle Microwave sensor dip switches to select desired output
Reference/Location: | In case of issue, contact Installation Engineer: | |||||
FULL RECHARGE TIME 24 HOURS | DURATION 3 HOURS | |||||
Ndekọ ule | ||||||
AFỌ 1 | AFỌ 2 | AFỌ 3 | ||||
Nnwale kwa ọnwa | Binyere aka | Ụbọchị | Binyere aka | Ụbọchị | Binyere aka | Ụbọchị |
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
Na-arụ ọrụ | ||||||
3-Hour Test |
Images are for information only. Phoebe LED shall not be held liable for improper operation of the luminaire in circumstances where procedures and specifications have not been followed correctly. Crompton Lamps Limited maka afọ 2024
Tel: + 44 (0) 1274 657 088 Fax: + 44 (0) 1274 657 087 Web: www.cromptonlamps.com
FAQ
- Q: What is the battery type used in the Emergency Module?
A: The Emergency Module uses a 3.2V LiFePO4 1W / 1500mA battery. - Q: How do I select different light levels for the Daylight Sensor?
A: Toggle the Dip Switch settings as per the provided settings for different light levels.
Akwụkwọ / akụrụngwa
![]() |
ORACLE 17009 Microwave Sensor Module [pdf] Ntuziaka nwụnye 16927, 16934, 17009, 17009 Microwave Sensor Module, 17009, Microwave Sensor Module, Sensor Module |