Installation Guide for ORACLE models including: 16927, 16934, 17009, 17009 Microwave Sensor Module, 17009, Microwave Sensor Module, Sensor Module


File Info : application/pdf, 4 Pages, 578.45KB

PDF preview unavailable. Download the PDF instead.

Oracle Plus Instructions
Installation Instructions

IP20 IK08

Microwave Sensor

C Install Microwave Sensor

Product Code

C.1

16927

Code

Length Width Height

Wattage

Voltage

IP Rating

IK Rating

Total Lumens

Ambient Operating Beam Temperature Angle

Weight

16897 4ft/1200mm 61mm 71mm 20/26/30/37W

16963

5ft/1500mm 61mm 71mm

30/35/42/50W

220-240V 50/60Hz

IP20

16910 6ft/1800mm 61mm 71mm 35/42/50/62W

Modules

16927 Microwave Sensor Module

16934 3-Hour Emergency Module with Manual Test Function

17009 3-Hour Emergency Module with Self Test Function

5500lm IK08 7500lm
9300lm

-20ºC to 50ºC

120º

1.25 KG 1.6 KG 1.9 KG

0.04KG 0.234KG 0.234KG

A Preparation

965mm

Use an appropreate ammount of fixtures to hold the unit weight
B Open unit

Ø6 x 30mm
Prepare surface/mount ensure mount can hold the product weight

Microwave Sensor Module
C.1 Align with tabs
D Install Emergency Module
Product Code
16934 17009

C.2
C.2 Push until locked into position
3-Hour Emergency Module

Push in lock buttons on either end and open as indicated

D.1 Align with tabs

D.2 Turn locking tabs into locked position

D Install Emergency Module (Continued)

D.3

D.4

D.5

D.6

6.1 D.7
6.2

1-3 second hold = 5 sec. EM test >10 second hold = RESET

D.3 Open battery compartment
D.5 Close battery compartment
D.7 For Manual test follow above testing guide, open cover for access.

D.4 Connect 3.2V LiFePO4 1W / 1500mA battery D.6 Push out LED status light bung 6.1 Align LED status light 6.2 Push LED status light into place

E Wiring + Connection Information

Wiring Diagram

Standard Connection

NEUTRAL N

EARTH

LIVE L
switched

B

A

Sensor Connection

B

B

Emergency Wiring Diagram
NEUTRAL N
EARTH
LIVE L
switched
LIVE L1

A(s)

A

Emergency Connection

B(s) B

A

A

Emergency Plus Sensor Connection

A(s)

B(s)

B

B

AA

F Final Install
Offer up luminaire

Screw into position using appropreate fixings

G Emergency Indicator

LED

LED Colour

ON

GREEN

ON / OFF / ON (0.25 sec)

GREEN

ON / OFF / ON (1 sec)

GREEN

ON

RED

ON / OFF / ON (0.25 sec)

RED

ON / OFF / ON (1 sec)

RED

OFF

RED + GREEN

Status
Battery Good On / Off Test
Timed Test LED OR Power Issue Low or Faulty Battery Charge or Live Error Switch Live or Live Error

3.2V LiFePO4 1W / 1500mA battery

Non-Replaceable LED
H CCT Settings

Non-Replaceable control gear Battery Replaceable by Professional

Cool White

Daylight

Warm White

Close fitting

Ensure locking clips have engaged

Turn off power and open cover

Toggle CCT switch to select colour settings

I Wattage Selection Settings

16897 - 4 FT Oracle Plus

Power
(W)

Dip Switch Settings

1

2

3

22

-- -- ON

27

-- ON --

34 ON -- --

40

-- -- --

16963 - 5 FT Oracle Plus

Power Dip Switch Settings

(W)

1

2

3

30

-- -- ON

35

-- ON --

42 ON -- --

52

-- -- --

16910 - 6 FT Oracle Plus

Power Dip Switch Settings

(W)

1

2

3

36

-- -- ON

42

-- ON --

50 ON -- --

63

-- -- --

Turn off power and open cover

Toggle Wattage selection dip switches to select output power

J Microwave Sensor Settings

Detection Area

Range

Dip Switch Settings

1

2

100%

ON

ON

75%

ON

--

50%

--

ON

25%

--

--

Daylight Sensor

Light Level

Dip Switch Settings

6

7

8

2 LUX

ON ON ON

10 LUX

ON ON --

25 LUX

-- ON --

50 LUX

ON --

--

DISABLED -- -- --

Hold Time
Time
5 Seconds 30 Seconds
1 Minute 3 Minutes 5 Minutes 10 Minutes 20 Minutes 30 Minutes

Dip Switch Settings

3

4

5

ON ON ON

ON ON --

ON -- ON

ON -- --

-- ON ON

-- ON --

-- -- ON

-- -- --

Microwave Sensor Module

Turn off power and open cover

Toggle Microwave sensor dip switches to select desired output

Reference/Location:

In case of issue, contact Installation Engineer:

......................................................................... ...................................................................................

FULL RECHARGE TIME 24 HOURS

DURATION 3 HOURS

TEST RECORD

YEAR 1

YEAR 2

YEAR 3

MONTHLY TEST Signed Date Signed Date Signed Date

Functional

Functional

Functional

Functional

Functional

Functional

Functional

Functional

Functional

Functional

Functional

Functional

3-Hour Test

Images are for information only. Phoebe LED shall not be held liable for improper operation of the luminaire in circumstances where procedures and specifications have not been followed correctly. Crompton Lamps Limited 2024
Tel: +44 (0)1274 657 088 Fax: +44 (0)1274 657 087 Web: www.cromptonlamps.com



References

Adobe PDF Library 17.0 Adobe InDesign 19.4 (Windows)