HEMOMATIK-logo

HEMOMATIK ITP17 Universal Process Indicator

HEMOMATIK -ITP17 -Universal-Process-Indicator product

تعارف

This manual describes the functions, configuration, mounting and operating instructions of the ITP17 universal process indicator (hereinafter referred to as the device).
Connection, setup and maintenance of the device must be performed only by fully qualified personnel after reading this user guide.

اصطلاح ۽ مخفف

PC – personal computer akYtec Tool Pro – configuration software
USB (Universal Serial Bus) – serial communication interface

مٿانview

The device is designed to measure and indicate signals of resistance temperature detectors (RTD), thermocouples (TC), pyrometers, DC voltage and DC signals (U / I signals).

افعال

  • measuring and displaying a measured value on the digital display;
  • signalling by color-coded indication about exceeding the set thresholds of the measured value;
  • signalling when the value is in the critical zone;
  • setting of the measured value according to the on/off- law using a discrete output based  on a transistor switch;
  • indication of a break or short circuit in the “device-sensor” communication line.

وضاحتون

ٽيبل 1 وضاحتون

پيرا ميٽر قدر
برقي
بجلي جي فراهمي 24 (10..30) VDC
بجلي جو استعمال، وڌ ۾ وڌ. 1 ڊبليو
سامان ڪلاس III
Galvanic isolation between domain of combined power and output interface and input domain 500 V
انپٽ سگنل
نمبر 1
Input resistance at voltage measuring, min. 100 ڪلو
ان پٽ Voltage drop (at current measuring), max. 1.6 V
Input signals supported ڏسو سيڪشن 6
Sampling time, max. 1 ايس
Full-scale accuracy , max. RTD, U / I signals

TC, pyrometers

 ± 0,25%

± 0,5%

حرارت جو اثر 0,2 of full-scale accuracy limit/ 10 °C
ٻاھر
NPN transistor, loading capacity 200 mА, 42 VDC
Length of signal line, max. 30 م
ٺاھ جوڙ انٽرفيس
Connector for configuration with akYtec Tool Pro مائڪرو USB
ڏيکاريو
 اشارو one 4–digit and 7– segment indicator
رنگ 3
ڪردار جي اوچائي 14 ملي ميٽر
مشيني
طول و عرض 48 × 26 × 72 ملي ميٽر
IP code (front / rear) (IP65 / IP20)
ايم بي ايف 100000 ڪلاڪ
سراسري خدمت زندگي 12 سال
وزن لڳ ڀڳ 150 جي

ماحولياتي حالتون

The device is designed for natural convection cooling which should be taken into account when choosing the installation site.
The following environmental conditions must be observed:

  • clean, dry and controlled environment, low dust level;
  • closed non-hazardous areas, free of corrosive or flammable gases.

جدول 2 ماحولياتي حالتون

حالت جائز حد
ماحول جي درجه حرارت -40…+60 °C
نسبتي نمي 30…80% (غير ڪنڊينسنگ)
نقل و حمل ۽ اسٽوريج جي درجه حرارت -25 ... +55 س
Transportation and storage relative humidity 5…95% (غير ڪنڊينسنگ)
اوچائي up to 2000 m ASL
EMC emission / immunity conforms to IEC 61000-6-3-2016

نوٽ
When operating the device at an altitude above 1000 m above sea level, it is  necessary to take into account the reduction of the electrical insulation as well as  the reduction in the cooling effect of the air.

انپٽ سگنل

Table 3 Signals and sensors 

اشارو وصف ماپ حد*
آر ٽي ڊي
С 50 Cu50 (α = 0,00426 °С-1) -50…+200 °С
50 С 50М (α = 0,00428 °С -1) -180…+200 °С
ص 50 Pt50 (α = 0,00385 °С-1) -200…+850 °С
50 ص 50P (α = 0,00391 °С -1) -200…+850 °С
سي100 Cu100 (α = 0,00426 °С-1) -50…+200 °С
100 سي 100М (α = 0,00428 °С-1) -180…+200 °С
پي 100 Pt100 (α = 0,00385 °С -1) -200…+850 °С
100 ص 100P (α = 0,00391 °С -1) -200…+850 °С
100n 100N (α = 0,00617 °С -1) -60…+180 °С
پي 500 Pt500 (α = 0,00385 °С -1) -200…+850 °С
500 ص 500P (α = 0,00391 °С -1) -200…+850 °С
سي500 Cu500 (α = 0,00426 °С -1) -50…+200 °С
500 سي 500М (α = 0,00428 °С -1) -180…+200 °С
500n 500N (α = 0,00617 °С -1) -60…+180 °С
C 1.0 Cu1000 (α = 0,00426°С-1) -50…+200 °С
1.0 سي 1000М (α = 0,00428 °С-1) -180…+200 °С
ص 1.0 Pt1000 (α = 0,00385 °С-1) -200…+850 °С
1.0 ص 1000P (α = 0,00391 °С-1) -200…+850 °С
1.0 ن 1000N (α = 0,00617 °С-1) -60…+180 °С
TC
tC.L L -200…+800 °С
tP.HA К -200…+1300 °С
tC.J J -200…+1200 °С
tC.n N -200…+1300 °С
tC.t Т -200…+400 °С
tC.S S 0…+1750 °С
tC.r R 0…+1750 °С
tC.b В +200…+1800 °С
tC.A1 A-1 0…+2500 °С
tC.A2 A-2 0…+1800 °С
tP.A3 A-3 0…+1800 °С
TC in accordance with DIN 43710
tC.dL L -200…+900 °С
I signals**
I 0.5 0…5 mА 0…100%
I0.20 0…20 mА 0…100%
I4.20 4…20 mА 0…100%
U signals**
U-5.5 -50…+50 mV*** 0…100%
U 0. 1 0…1 وي 0…100%
U0.10 0…10 وي 0…100%
U2.10 2…10 وي 0…100%
پيرو ميٽرس
PIr.1 RК-15 +400…+1500 °С
PIr.2 RК-20 +600…+2000 °С
PIr.3 RS-20 +900…+2000 °С
PIr.4 RS-25 +1200…+2500 °С

At the temperature over 999,9 and under -199,90C the value of the least significant digit equals 10C.
The values depend on the di.Lo and di.Hi parameters.
Accuracy is not standardized.

حفاظت

خبردار
خطرناڪ جلدtage!
Electric shock could kill or seriously injure.

  • All work on the device must be performed by a fully qualified electrician.
  • پڪ ڪريو ته مکيه حجمtage سان ملي ٿوtage جي ڊوائس تي نشان لڳل.
  • Ensure that the device is provided with its power supply line and electric  fuse.
  • The device may not be used in aggressive environments, in atmospheres in  which there are chemically active substances.
  • The output port and internal electrical elements of the device must be protected from the humidity.

نوٽيس

  • De-energize the device before working on it. Switch on the power supply  only after completing all work on the device.

چڙهڻ

ڊوائيس نصب ڪرڻ لاء:

  • Prepare the mounting cutout with Ø of 22.5 mm in the switchboard where the device should be mounted (see Fig. 2).
  • Carefully position the supplied gasket (see Fig.
  •  Place the device with the installed gasket in  the prepared mounting cutout and tighten the nut (included in the scope of delivery) to fix the device.

نوٽيس
Do not use any tools to tighten the nut. Tighten the nut only by hand.

HEMOMATIK -ITP17 -Universal-Process-Indicator (2)Removing proceeds in the reverse order. HEMOMATIK -ITP17 -Universal-Process-Indicator (3)

ڪنيڪشن

عام معلومات
Signal cables should be routed separately from the power supply cables as well as from the cables which are sources of high-frequency and impulse interference.

  • For high-quality clamping and reliable electrical connections, it is recommended to use:
  • copper multicore wires, diameter after tinning – 0.9 mm (17 cores, AWG 22) or 1.1 mm (21 cores, AWG 20);
  • copper wires with single-wire cores, diameter from 0.51 to 1.02 mm (AWG 24-18).
  • The ends of the wires should be stripped of insulation by 8 ± 0.5 mm (see Fig. 4) and, if  necessary, tinned.

HEMOMATIK -ITP17 -Universal-Process-Indicator (4)

 

وائرنگ

احتياط
To protect the device input from the influence of industrial electromagnetic interference, the “device-sensor” communication lines should be shielded. To protect the device input circuits from possible breakdown by static electricity charges accumulated on the “device-sensor” communication lines, their wires  should be connected to the shield ground screw for 1–2 s before connecting to  the device terminal block.
Connect the “device – sensor” communication lines to the primary converter and the device input and connect the device to the power supply (see Fig. 6).

HEMOMATIK -ITP17 -Universal-Process-Indicator (5)تصوير 6 وائرنگ ڊاگرام
To protect the device against microseconds’ impulse noise of the output device (open collector) on the terminals “DO” and “-“, it is recommended to use connecting lines no longer than 30 meters or install devices for protection against impulse noise on the DC line. The VD1 diode should be located as close as possible to the terminals of the relay winding. The parameters of the diode are selected in accordance with the following rules:

The forward current of the diode must be at least 1.3 R1 (1.3 of the relay coil current).

Indication and control

  • The 4– digit and 7– segment indicator on the front panel is designed to display measured values, alarms and device parameters. The segments of the digital indicator can light up in  one of the following colors (see Section 13):
  • سائو؛
  • ڳاڙهو؛
  • پيلو.

HEMOMATIK -ITP17 -Universal-Process-Indicator (6)There is a micro-USB connector on the bottom of the enclosure.

HEMOMATIK -ITP17 -Universal-Process-Indicator (1)

Error indication and remedy

Being powered the device starts to operate. If the indicated values do not correspond to the real measured values, check the following:

  • sensor function and communication line integrity;
  • correctness of sensor connection;
  • settings of scaling parameters (di.Lo and di.Hi).

Table 5 Error indication and remedy 

اشارو وصف علاج
ايڇ ايڇ The measured input value is above the upper limit  

Check the sensor code and measured value compliance

ايل ايل ايل ايل The measured input value is below the lower limit
 Hi The calculated value exceeds the maximum possible positive value that can be displayed on 4 digits of the indicator  

 

Readjust the dP.t پيرا ميٽر

 

Lo

The calculated value is less than the minimum possible negative value that can be displayed on 4 digits of the indicator
 |——|  

سينسر جي ڀڃڪڙي

Check the signal line. If the signal line isn’t broken and

the connection is correct, contact akYtec service staff

Er.[ ] Cold junction sensor (CJS) failure Contact akYtec service staff
اشارو وصف جائز

قدر

ڪارخانو سيٽنگون
in.t ان پٽ سگنل ڏسو سيڪشن 6 4…20 ايم اي
td ڊجيٽل فلٽر وقت مسلسل 0…10 سيڪنڊ 0
SQrt Square root function (for U signals) چالو بند آف
di.Lo Signal lower limit (for I / U signals) -1999…9999 0
di.Hi Signal upper limit (for I / U signals) -1999…9999 100
dP.T ڊيسيمل پوائنٽ پوزيشن -a-u-to-

-.-.- –

– – -.-
2u3u RTD connection: 2–wire or 3–wire 2-Ln

3-Ln

3-Ln
ڪر Offset correction of the measured input value –1999 …9999 0
 

سي اين ٽي

ڪنٽرول فنڪشن:

OFF / Heating / Cooling /

Alarm within limits (П) / Alarm outside limits (U) (see تصوير 10)

 

oFF/HEAt/ CooL/П/U

 

U

SP.Lo Setpoint lower limit -1999…9999 0
SP.Hi Setpoint upper limit -1999…9999 30
 

 

 

A.HYS

Hysteresis. When “Alarm within limits (П)” or “Alarm outside limits (U)” are selected, the hysteresis blocks the actuation of the output unit with minor

fluctuations at the SP.Lo and SP.Hi boundary. The parameter is not

ڏيکاريل جڏهن سي اين ٽي = oFF/HEAt/CooL

0…9999  

 

0

di.Sh Characteristics offset –1999 …9999 0
out.E Output device state in case of sensor failure چالو بند آف
d.FnC چمڪندڙ فنڪشن چالو بند آف
Zon.1 Thresholds for changing the color of indicator zones 1999…9999 0
Zon.2 50
Zon.3 80
Zon.4 100
Zon.5 100
CoL.1 Indicator zone color جي آر اين/ڳاڙهو/ييل جي آر اين
CoL.2 ييل
CoL.3 ڳاڙهو
CoL.4 ڳاڙهو
CoL.D Basic indication color outside color

زون

جي آر اين/ڳاڙهو/ييل جي آر اين
Br.R Brightness of red* 0…100 100
Br.G Brightness of green* 0…100 100
Br.Y Brightness of yellow* 0…100 100
BL.YR Balance of red/green in yellow* 0…100 100
 نوٽ

* The parameter doesn’t change by resetting to factory settings.

الارم سيٽنگون

رنگ جو اشارو
You can set the indicator color modes depending on the input value using Zon.n and COL.n parameters. Zon. n parameters must be recorded sequentially from the lowest to the highest.HEMOMATIK -ITP17 -Universal-Process-Indicator (2)

Zon.1 = 50.0; Zon.2 = 80.0; Zon.3 = 100.0; CoL.1 = YELL; CoL.2 = rEd; CoL.d=Grn
Fig. 9 Changing of indication color

الارم منطق
The output device can be used for control or alarm indication.
You can select the alarm logic with the Cnt parameter (see Table 6) in accordance with Fig. 10. HEMOMATIK -ITP17 -Universal-Process-Indicator (3)

سروس مينيو

Table 7 Service menu

اشارو وصف
DEV.t ڊوائيس جو قسم
VEr.F فرم ویئر ورزن
CJS.E Cold junction sensor on/ off
d.rSt فيڪٽري سيٽنگن کي ٻيھر ڪريو

Current state: 0.

جڏهن اهو مقرر ڪيو ويو آهي 1, all device settings are reset to default values and the  device restarts

Configuration using akYtec Tool Pro
You can configure the device using akYtec Tool Pro software.
To connect the device to akYtec Tool Pro:

  1. Connect the device to a PC with the USB — micro USB cable.
  2. Start akYtec Tool Pro.
  3. تي ڪلڪ ڪريو ڊوائيسز شامل ڪريو.
  4. Select the COM port assigned to the device in the Interface drop-down menu of the  Network parameters tab. You can check the port number and name in Windows Device Manager.
  5. Select Modbus RTU in the Protocol drop-down menu.
  6. Select the necessary device in the Measuring devices category of the Devices drop- down menu.
  7. HEMOMATIK -ITP17 -Universal-Process-Indicator (4)If the device is connected for the first time, select Manually in the Connection setup tab and set the following values: HEMOMATIK -ITP17 -Universal-Process-Indicator (1)
  8. Select Find device.
  9. Enter the address of the connected device (default address — 16).
    نوٽ
    The device is available under addresses from 1 up to 255.
  10. Click Search. The device with the address will be displayed in the window.
  11. Select the checkbox next to the device and click the ОК button.

To get more information about the connection and operation of the device, use the HELP menu of akYtec Tool Pro or press F1 to call up HELP in the program.

سار سنڀال

The safety requirements must be observed when the maintenance is carried out.

خبردار
Cut off all power before maintenance.

The maintenance includes:

  • cleaning of the housing and terminal blocks from dust, dirt and debris
  • checking the device fastening
  • checking the wiring (connecting wires, terminal connections, absence of mechanical damages).

نوٽيس
The device should be cleaned with a dry or slightly damp cloth only. No abrasives or solvent-containing cleaners may be used.

ٽرانسپورٽ ۽ اسٽوريج

Pack the device in such a way as to protect it reliably against impact for storage and  transportation. The original packaging provides optimum protection.  If the device is not taken immediately after delivery into operation, it must be carefully  stored at a protected location. The device should not be stored in an atmosphere with  chemically active substances.
The environmental conditions must be taken into account during transportation and storage.

نوٽيس
The device may have been damaged during transportation.
Check the device for transport damage and completeness!
Report the transport damage immediately to the shipper and akYtec GmbH!

پهچائڻ جي گنجائش

  • ITP17 universal process indicator 1 pc.
  • User guide 1 pc.
  • Set of mounting elements 1 pc.

نوٽ
The manufacturer reserves the right to make additions to the scope of delivery.

ٽيليفون: +46 (0)8 771 02 20
info@hemomatik.se

دستاويز / وسيلا

HEMOMATIK ITP17 Universal Process Indicator [pdf] استعمال ڪندڙ ھدايت
ITP17, HM 2503, ITP17 Universal Process Indicator, ITP17, Universal Process Indicator, Process Indicator, Indicator

حوالو

تبصرو ڇڏي ڏيو

توهان جو اي ميل پتو شايع نه ڪيو ويندو. گهربل فيلڊ نشان لڳل آهن *