Elitech-LOGO

Elitech RCW-360 Plus Multi Use Real Time Data Logger

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger-PRODUCT

Zathaview

This device is a wireless Internet of Things (loT) monitoring product that offers real-time monitoring, alarms, data logging, data uploading, and large screen display for temperature and humidity at monitoring points. When paired with the “Elitech Cold Cloud” cloud platform and app, it enables remote data viewing, historical data queries, remote alarm notifications, and device GPS positioning (only for the 4G version). The product is widely used in industries such as food, pharmaceuticals, catering, and international warehousing logistics. It features an aviation plug for easy sensor replacement. The main unit supports both 4G and Wi-Fi, allowing you to choose between 4G or Wi-Fi communication methods. The main unit comes with dual channels, and the external probes offer several options: single temperature, dual temperature, gel bottle, ultra-low temperature, and temperature and humidity.

Mawonekedwe

  • The product is suitable for various occasions, including warehouse, refrigerated storage, refrigerator car, shade cabinet, medicine cabinet, refrigerator lab1 etc;
  • Kukula kocheperako, mawonekedwe apamwamba, kapangidwe ka thireyi yamaginito, kukhazikitsa kosavuta;
  • Chiwonetsero chachikulu chamtundu wa TFT, chokhala ndi zinthu zambiri;
  • Batire ya lithiamu yomangidwanso imathandizira kukweza kwanthawi yayitali nthawi yeniyeni pambuyo podula mphamvu;
  • Chipangizo cha alamu chomangidwira chimatha kuzindikira alamu yakomweko;
  • Kuyika kwa GPS kumalola kutsata nthawi yeniyeni ya zida (mtundu wa 4G wokha);
  • Ntchito yosindikiza ya Bluetooth imathandizira kusindikiza ndi kujambula pamasamba;
  • Illumination intensity sensing function enables detection of the door up/dose status to realize automatic screen-on/off;
  • Mitundu ingapo ya kafukufuku yomwe ilipo (onani mndandanda wa zosankha zachitsanzo kuti mudziwe zambiri).

Chiyankhulo

4G mtundu Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (3)

WIFI Baibulo Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (4)

  1. Monitoring status
  2. Channel 1
  3. Kutentha kwamakono
  4. Malire apamwamba
  5. Chizindikiro chotsikirapo
  6. Channel 2
  7. Malire a alamu apamwamba ndi otsika pokhazikitsa kutentha
  8. Malire a alamu apamwamba ndi otsika pokhazikitsa chinyezi
  9. Kulimba kwa siginecha
  10. Nthawi ndi tsiku
  11. Chizindikiro cha GPS Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (5)
  12. Chizindikiro champhamvu Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (6)
  13. Chizindikiro cha WIFI Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (7)
  14. The number of local data cache groups that have not yet been uploaded to network  15 Current humidity
  15. Temperature and humidity display area (actual version shall prevail) 17  Current Light Intensity

Pamene kutentha ndi chinyezi ndipamwamba kuposa malire apamwamba, zikhalidwe zimakhala zofiira; Pamene kutentha ndi chinyezi ndi otsika kuposa malire m'munsi, makhalidwe ore mu buluu.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (8)

  1. Photosensitive sensor
  2. Kafukufuku wakunja 1
  3. Batani la / off
  4. Maginito khadi tray
  5. Mawonekedwe a SIM khadi (mtundu wa 4G wokha)
  6. "Yambani" batani
  7. Kutengera mawonekedwe
  8. Chizindikiro cholipiritsa
  9. Chizindikiro cha Alamu
  10. Kafukufuku womangidwa
  11. Kafukufuku wakunja 2
  12. Chophimba
  13. Menu” button
  14. Imani" batani
  15. External Probe Interface

 Mndandanda Wosankha Zitsanzo

Collection Host: R[W-360 Plus
Tips:The specific host model is subject to the actual product; The host does not come with a probe. Choose a probe according to actual needs, and each channel can be adapted to the following types of probes.
Probe model: the conventional probe models are shown in the table below

Mtundu wa probe Single temperature Kutentha kwapawiri Ciel bottle temperature Kutentha ndi chinyezi Kutentha kochepa kwambiri
Chitsanzo T□lX-TE-H T□lX-TOE-H T□3X-TE(GLE)-H HT□3X-THE-H PT100IIC-TLE-H
[able 5 mita 5 mita 2 mita 5 mita 3 mita
Mfundo One temperature probe Two temperature probe One temperature probe 1 temperature probe and 1 humidity probe One temperature probe
Mtundu -4O°C~B5°C PT100IIC-TLE-H H:0%RH~100%RH -2□O°C~15O°C
Kulondola ±O.S°C T:±O.SOC H,±5%RH ±O.5°C(-4O~B5°C)±1°C(-1□O~15O°C)±2°C(others)

Note: The specific sensor type is subject to the actual product.

 Technical Parameters

  1. Power Supply: Power adapter: 5V2A (DC), Type-( interface
  2. Battery: 4000mAh/3.7V rechargeable lithium battery
  3. Endurance: No less than 20 days (at 25°(, upload interval 5 minutes, good network environment) No less than 7 days (at 25°(, upload interval 5 minutes, GPS positioning, good network environment)
  4. Kulondola Kwamayimidwe:
    • GPS: . SO meters, positioning interval consistent with recording interval, and not less than 5 minutes
    • LBS: Urban areas :S.500 meters, rural areas s3km
  5. Storage Capacity: 100,000 data sets (cyclic storage)
  6. Recording Interval: 1 minute to 24 hours, default: normal recording interval 5 minutes, alarm recording interval 2 minutes
  7. Upload Interval: 1 minute to 24 hours, default: normal upload interval 5 minutes, alarm upload interval 2 minutes
  8. Local Alarm: Buzzer, LED
  9. Platform Alarm: Voice, SMS, WeChat, APP, Email
  10. Mulingo Wopanda madzi: IP65
  11. 0perating Environment: -20~60°C, 0~100%RH (no condensation), below 1km altitude
  12. Storage Environment: -20~60°(, 0~90%RH
  13. Product Weight: Main unit approximately 200g
  14. Mankhwala Makulidwe: 109 * 69.5 * 23mm

Malangizo Ogwiritsira Ntchito

  1. Kuyika ndi kuchotsa kafukufuku (Mawonekedwe a mutu wa ndege okha)
    Monga momwe chithunzichi chikusonyezera, choyamba gwirizanitsani pulagi ya ndege ndi mawonekedwe ndikuyiyika, kenaka mutembenuzire wononga koloko kuti mukonze kafukufukuyo. Kuti musungunuke, tembenuzirani wononga molunjika ndikutulutsa kafukufukuyo. Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (9)
  2. Kulipira
    Lumikizani ku adaputala yamagetsi kudzera pa chingwe cha USB.
    Mukamalipira, chizindikiro cholipiritsa chimawala; Ikayimitsidwa kwathunthu, chizindikiro cholipiritsa chimakhala choyaka.
  3. Yatsani/kuzimitsa
    Dinani batani la kuyatsa / kuzimitsa kwa masekondi atatu kuti mutsegule / kuzimitsa chipangizocho.
    Sichiloledwa kuzimitsa pamene kujambula kukuchitika.
  4. Yambani kujambula
    Chidacho chikagwira ntchito mosayang'aniridwa, dinani batani la "Yambani" kwa masekondi atatu; dinani "Yambani" batani mu tumphuka bokosi kuti alemba "Inde", ndiyeno dinani "Menyu" batani kutsimikizira chiyambi. Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (10)
  5. Siyani kujambula
    Pamene zida zikuyang'aniridwa, dinani batani la "Imani" kwa masekondi atatu; dinani "Yambani" batani mu tumphuka bokosi kuti alemba "Inde", ndiyeno dinani "Menyu" batani kutsimikizira kuyimitsa. Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (11)
  6. Maximum, Minimum, Average View
    Click the “Menu” button to enter the maximum, minimum and average display page . Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (12)
  7. Menyu
    Press the 11 menu11 button for 3 seconds to enter the main menu page.
    The functions of the buttons in the menu are as follows:
    • “Menu” button: confirm/select
    • "Yambani" batani: kusintha
    • "Imani" batani: kusintha pansi

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (13) View zambiri zamasinthidwe
Including: normal recording interval, alarm recording interval, normal uploading interval, alarm uploading interval, buzzer alarm on/off, GPS positioning on/off, temperature alarm delay, humidity alarm delay and other parameters.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (14)

View chidziwitso cha chipangizo
Including: device name, GUI□, offline data capacity, IME1,1cc1□.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (15)

 Zowonetsera

  • Enter the “Display Settings” menu to set bacl<light brightness, backlight time and date format. Brightness: 5 levels of brightness available, and 5 is the brightest.
  • Nthawi yowunikira kumbuyo: Zosankha 4 zomwe zilipo, mwachitsanzo 1 min, 10 min, 30 min ndi nthawi zambiri.
  • Date format: 3 options available, i.e. yyyy-mm-dd, dd-mm-yyyy, mm-dd- yyyy .

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (16)

 Onjezani chipangizo papulatifomu ndikugwiritsa ntchito. Chonde onani IV Elitech iCold.

Elitech iCold

  1. Tsitsani ndikukhazikitsa APP
    Please scan the QR code on the cover of the manual or search Elitech iCold APP Store or Google play to download Elitech App.
  2. Account registration and APP Login
    Open the APP, in the login page, as shown in Figure 1, follow the prompts, enter the verification information, and click “Login”. After entering the APP, select “mm Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (17)

PS:

  • If you have not an account, please click on “Register” in the login page, as shown in Figure 2, follow the prompts and enter verification information to complete account registration.
  • If you forget the password, click “Forget password” to find password as shown in Figure 3. According to the prompts to finish verfication and find out password.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (22)

Onjezani Chipangizo

  1. DinaniElitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (19) mu ngodya yapamwamba kumanja
  2. DinaniElitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (20) in the upper right corner, scan the QR code or enter GUI□ back on the device, then fill in the device name and choose time zone.
  3. Dinani "Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (21)“, the device is added.
    • Tip: If the device shows off line After being added to the platform, first check the network icon and offline records on the device. If everything is normal, please wait for a few minutes or restart the device before turning it on. The device uploads data according to the set reporting cycle; If the device is offline for a long time, please check if the SIM card is overdue. Ultimately unable to resolve, please call the service hotline for consultation.
  4. WIFI yogawa network
    1. Press and hold the “Menu” key, briefly to enter the “WIFI Config” page.
    2. Press the “Menu” key and a Wi-Fi icon Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (23)“will appear in the upper left corner of the device
    3. Use the app to distribute the network with this device via Wi-Fi, as shown in the following figures 1-3Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (24)
  5. Configure probe type
    When using the device for the first time or changing the probe type, it is necessary to reconfigure the probe, as shown in Figure 4 and Figure 5 for operation;
    Operation method: Log in to the APP ➔select the device to be changed ➔select “Parameter Configuration” ➔select “User Parameters” ➔select the corresponding probe model based on the actual selected probe type and channel ➔click “SET”.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (25)Zindikirani: 

  1. After reconfiguring the probe type, it is necessary to wait for an upload cycle to synchronize the probe type to the device, or the device can be restarted to synchronize immediately.
  2. Replace the probe. Due to the time difference between replacing the probe and configuring it, there may be faulty data in the data list.

Kasamalidwe ka Chipangizo 

  1. After the device has started recording and added to the platform, wait for the data to be uploaded, then display online. Start recording reference 111-3.
  2. If you want to make other configurations for the device, please enter the device information page, such as historical data, temperature unit, upper and lower alarm limits, upload record interval, etc. As shown in Figure 7 9 .
    Note: After the device temperature unit is changed, it needs to be changed under user settings(More-Setting).

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (26)

Elitech iCold Platform

For more functions, please log in Elitech icold Platform: new.i-elitech.com.

Zowonjezera
Deta yaulere & ntchito yapapulatifomu yapamwamba idzayatsidwa chipangizochi chikalembetsedwa koyamba ku nsanja ya Elitech. Pambuyo pa nthawi yoyezetsa, makasitomala ayenera kubwezeretsanso chipangizocho potchula buku la ntchito.

Zolemba / Zothandizira

Elitech RCW-360 Plus Multi Use Real Time Data Logger [pdf] Buku Logwiritsa Ntchito
RCW-360Plus-WG, RCW-360 Plus Multi Use Real Time Data Logger, Multi Use Real Time Data Logger, Real Time Data Logger, Time Data Logger, Data Logger

Maumboni

Siyani ndemanga

Imelo yanu sisindikizidwa. Minda yofunikira yalembedwa *