This device is a wireless Internet of Things (loT) monitoring product that offers real-time monitoring, alarms, data logging, data uploading, and large screen display for temperature and humidity at monitoring points. When paired with the “Elitech Cold Cloud” cloud platform and app, it enables remote data viewing, historical data queries, remote alarm notifications, and device GPS positioning (only for the 4G version). The product is widely used in industries such as food, pharmaceuticals, catering, and international warehousing logistics. It features an aviation plug for easy sensor replacement. The main unit supports both 4G and Wi-Fi, allowing you to choose between 4G or Wi-Fi communication methods. The main unit comes with dual channels, and the external probes offer several options: single temperature, dual temperature, gel bottle, ultra-low temperature, and temperature and humidity.

Karatteristiċi

  • The product is suitable for various occasions, including warehouse, refrigerated storage, refrigerator car, shade cabinet, medicine cabinet, refrigerator lab1 etc;
  • Daqs kompatt, dehra moda, disinn ta 'trej tal-karta manjetika, installazzjoni faċli;
  • Wiri kbir ta 'skrin bil-kulur TFT, rikk fil-kontenut;
  • Batterija tal-litju rikarikabbli inkorporata tippermetti upload ta 'dejta f'ħin reali għal żmien twil wara li tinqata' l-enerġija;
  • Apparat ta 'allarm tal-ħoss tad-dawl inkorporat jista' jirrealizza allarm lokali;
  • Il-pożizzjonament tal-GPS jippermetti traċċar f'ħin reali tal-post tat-tagħmir (verżjoni 4G biss);
  • Il-funzjoni tal-istampar Bluetooth tippermetti l-istampar u r-reġistrazzjoni tad-dejta fuq il-post;
  • Illumination intensity sensing function enables detection of the door up/dose status to realize automatic screen-on/off;
  • Tipi ta 'sonda multipli disponibbli (ara l-lista tal-għażla tal-mudell għad-dettalji).

Interface

Verżjoni 4G Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (3)

WIFI verżjoni Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (4)

  1. Status ta' monitoraġġ
  2. Kanal 1
  3. Temperatura kurrenti
  4. Marka tal-limitu ta' fuq
  5. Marka tal-limitu t'isfel
  6. Kanal 2
  7. Limiti ta' fuq u ta' isfel ta' allarm għall-issettjar tat-temperatura
  8. Limiti ta 'l-allarm ta' fuq u ta 'isfel għall-issettjar ta' l-umdità
  9. Intensità tas-sinjal
  10. Ħin u data
  11. Ikona tal-GPS Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (5)
  12. Ikona tal-istatus tal-enerġija Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (6)
  13. Ikona tal-WIFI Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (7)
  14. The number of local data cache groups that have not yet been uploaded to network  15 Current humidity
  15. Temperature and humidity display area (actual version shall prevail) 17  Current Light Intensity

Meta t-temperatura u l-umdità huma ogħla mil-limiti ta 'fuq, il-valuri huma bl-aħmar; Meta t-temperatura u l-umdità huma aktar baxxi mil-limiti aktar baxxi, il-valuri minerali bil-blu.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (8)

  1. Sensor fotosensittiv
  2. Sonda esterna 1
  3. Buttuna mixgħul/mitfi
  4. Trej tal-kard manjetiku
  5. Interface tal-karta SIM (verżjoni 4G biss)
  6. Buttuna “Ibda”.
  7. Interface tal-iċċarġjar
  8. Indikatur tal-iċċarġjar
  9. Indikatur tal-istat tal-allarm
  10. Sonda inkorporata
  11. Sonda esterna 2
  12. Skrin
  13. Menu” button
  14. buttuna Stop”.
  15. Interface tas-Sonda Esterna

 Lista tal-Għażla tal-Mudell

Collection Host: R[W-360 Plus
Tips:The specific host model is subject to the actual product; The host does not come with a probe. Choose a probe according to actual needs, and each channel can be adapted to the following types of probes.
Probe model: the conventional probe models are shown in the table below

Tip ta' sonda Single temperature Temperatura doppja Ciel bottle temperature Temperatura u umdità Temperatura ultra baxxa
Mudell T□lX-TE-H T□lX-TOE-H T□3X-TE(GLE)-H HT□3X-THE-H PT100IIC-TLE-H
[able 5 Meters 5 Meters 2 Meters 5 Meters 3 Meters
Punt One temperature probe Two temperature probe One temperature probe 1 temperature probe and 1 humidity probe One temperature probe
Firxa -4O°C~B5°C PT100IIC-TLE-H H:0%RH~100%RH -2□O°C~15O°C
Eżattezza ±O.S°C T:±O.SOC H,±5%RH ±O.5°C(-4O~B5°C)±1°C(-1□O~15O°C)±2°C(others)

Note: The specific sensor type is subject to the actual product.

 Parametri Tekniċi

  1. Power Supply: Power adapter: 5V2A (DC), Type-( interface
  2. Battery: 4000mAh/3.7V rechargeable lithium battery
  3. Endurance: No less than 20 days (at 25°(, upload interval 5 minutes, good network environment) No less than 7 days (at 25°(, upload interval 5 minutes, GPS positioning, good network environment)
  4. Preċiżjoni tal-Pożizzjonament:
    • GPS: . SO meters, positioning interval consistent with recording interval, and not less than 5 minutes
    • LBS: Urban areas :S.500 meters, rural areas s3km
  5. Storage Capacity: 100,000 data sets (cyclic storage)
  6. Recording Interval: 1 minute to 24 hours, default: normal recording interval 5 minutes, alarm recording interval 2 minutes
  7. Upload Interval: 1 minute to 24 hours, default: normal upload interval 5 minutes, alarm upload interval 2 minutes
  8. Local Alarm: Buzzer, LED
  9. Platform Alarm: Voice, SMS, WeChat, APP, Email
  10. Klassifikazzjoni li ma jgħaddix ilma minnha: IP65
  11. 0perating Environment: -20~60°C, 0~100%RH (no condensation), below 1km altitude
  12. Storage Environment: -20~60°(, 0~90%RH
  13. Product Weight: Main unit approximately 200g
  14. Dimensjonijiet tal-Prodott: 109 * 69.5 * 23mm

Istruzzjonijiet ta' Operazzjoni

  1. Installazzjoni u tneħħija tas-sonda (Interface tar-ras tal-inġenju tal-ajru biss)
    Kif muri fil-Figura, l-ewwel allinja l-plagg tal-avjazzjoni mal-interface u daħħalha, imbagħad dawwar il-kamin lejn l-arloġġ biex tiffissa s-sonda. Biex tiżżarma, dawwar il-kamin kontra l-arloġġ u iġbed is-sonda. Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (9)
  2. Iċċarġjar
    Qabbad mal-adapter tal-enerġija permezz tal-kejbil USB.
    Meta tiċċarġja, l-indikatur tal-iċċarġjar jteptep; Meta tkun iċċarġjata kompletament, l-indikatur tal-iċċarġjar ikun dejjem mixgħul.
  3. Qawwa mixgħul/mitfi
    Agħfas il-buttuna mixgħul/mitfi għal 5 sekondi biex tixgħel/itfi l-apparat.
    Mhux permess li jintefa meta r-reġistrazzjoni tkun fil-proċess.
  4. Ibda rrekordja
    Meta t-tagħmir ikun fi stat ta 'tħaddim mhux sorveljat, agħfas il-buttuna "Start" għal 5 sekondi; ikklikkja l-buttuna "Ibda" fil-kaxxa pop-up biex ikklikkja "Iva", u mbagħad ikklikkja l-buttuna "Menu" biex tikkonferma l-bidu. Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (10)
  5. Waqqaf ir-reġistrazzjoni
    Meta t-tagħmir ikun fi stat ta 'tħaddim immonitorjat, agħfas il-buttuna "Stop" għal 5 sekondi; ikklikkja l-buttuna "Ibda" fil-kaxxa pop-up biex ikklikkja "Iva", u mbagħad ikklikkja l-buttuna "Menu" biex tikkonferma l-waqfien. Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (11)
  6. Massimu, Minimu, Medja View
    Click the “Menu” button to enter the maximum, minimum and average display page . Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (12)
  7. Menu
    Press the 11 menu11 button for 3 seconds to enter the main menu page.
    The functions of the buttons in the menu are as follows:
    • “Menu” button: confirm/select
    • Buttuna “Start”: aqleb
    • Buttuna “Stop”: aqleb 'l isfel

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (13) View informazzjoni dwar il-konfigurazzjoni
Including: normal recording interval, alarm recording interval, normal uploading interval, alarm uploading interval, buzzer alarm on/off, GPS positioning on/off, temperature alarm delay, humidity alarm delay and other parameters.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (14)

View informazzjoni dwar l-apparat
Including: device name, GUI□, offline data capacity, IME1,1cc1□.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (15)

 Issettjar tal-wiri

  • Enter the “Display Settings” menu to set bacl<light brightness, backlight time and date format. Brightness: 5 levels of brightness available, and 5 is the brightest.
  • Ħin ta 'backlight: 4 għażliet disponibbli, jiġifieri 1 min, 10 min, 30 min u normalment mixgħula.
  • Date format: 3 options available, i.e. yyyy-mm-dd, dd-mm-yyyy, mm-dd- yyyy .

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (16)

 Żid l-apparat mal-pjattaforma u l-operat. Jekk jogħġbok irreferi għal IV Elitech iCold.

Elitech iCold

  1. Niżżel u Installa l-APP
    Please scan the QR code on the cover of the manual or search Elitech iCold APP Store or Google play to download Elitech App.
  2. Account registration and APP Login
    Open the APP, in the login page, as shown in Figure 1, follow the prompts, enter the verification information, and click “Login”. After entering the APP, select “mm Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (17)

PS:

  • If you have not an account, please click on “Register” in the login page, as shown in Figure 2, follow the prompts and enter verification information to complete account registration.
  • If you forget the password, click “Forget password” to find password as shown in Figure 3. According to the prompts to finish verfication and find out password.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (22)

Żid Apparat

  1. IkklikkjaElitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (19) fir-rokna ta’ fuq tal-lemin
  2. IkklikkjaElitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (20) in the upper right corner, scan the QR code or enter GUI□ back on the device, then fill in the device name and choose time zone.
  3. Ikklikkja “Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (21)“, the device is added.
    • Tip: If the device shows off line After being added to the platform, first check the network icon and offline records on the device. If everything is normal, please wait for a few minutes or restart the device before turning it on. The device uploads data according to the set reporting cycle; If the device is offline for a long time, please check if the SIM card is overdue. Ultimately unable to resolve, please call the service hotline for consultation.
  4. Netwerk ta 'distribuzzjoni WIFI
    1. Press and hold the “Menu” key, briefly to enter the “WIFI Config” page.
    2. Press the “Menu” key and a Wi-Fi icon Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (23)“will appear in the upper left corner of the device
    3. Use the app to distribute the network with this device via Wi-Fi, as shown in the following figures 1-3Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (24)
  5. Configure probe type
    When using the device for the first time or changing the probe type, it is necessary to reconfigure the probe, as shown in Figure 4 and Figure 5 for operation;
    Operation method: Log in to the APP ➔select the device to be changed ➔select “Parameter Configuration” ➔select “User Parameters” ➔select the corresponding probe model based on the actual selected probe type and channel ➔click “SET”.

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (25)Nota: 

  1. After reconfiguring the probe type, it is necessary to wait for an upload cycle to synchronize the probe type to the device, or the device can be restarted to synchronize immediately.
  2. Replace the probe. Due to the time difference between replacing the probe and configuring it, there may be faulty data in the data list.

Ġestjoni tal-Apparat 

  1. After the device has started recording and added to the platform, wait for the data to be uploaded, then display online. Start recording reference 111-3.
  2. If you want to make other configurations for the device, please enter the device information page, such as historical data, temperature unit, upper and lower alarm limits, upload record interval, etc. As shown in Figure 7 9 .
    Note: After the device temperature unit is changed, it needs to be changed under user settings(More-Setting).

Elitech-RCW-360-Plus-Multi-Use-Real-Time-Data-Logger- (26)

Elitech iCold Pjattaforma

For more functions, please log in Elitech icold Platform: new.i-elitech.com.

Top-up
Data b'xejn u servizz ta' pjattaforma avvanzata se jiġu attivati ​​wara li l-apparat ikun irreġistrat għall-ewwel darba fil-pjattaforma Elitech. Wara l-perjodu ta 'prova, il-klijenti jeħtieġ li jerġgħu jiċċarġjaw l-apparat billi jirreferu għall-manwal tat-tħaddim.

Dokumenti / Riżorsi

Elitech RCW-360 Plus Multi Use Real Time Data Logger [pdfManwal tal-Utent
RCW-360Plus-WG, RCW-360 Plus Multi Use Real Time Data Logger, Multi Use Real Time Data Logger, Real Time Data Logger, Time Data Logger, Data Logger

Referenzi

Ħalli kumment

L-indirizz elettroniku tiegħek mhux se jiġi ppubblikat. L-oqsma meħtieġa huma mmarkati *