Model NameEANØ x h [mm]f [Hz]U [V]* P [W]** Phi_v [lm]*** Eff. [lm/W]P_EM [W]Phi_v_EM [lm]
BLKH RD EL 250 P 12W MS 840 BK4099854286285262x7350/60220-2401212301022.3380
BLKH RD EL 250 P 12W MS 840 WT4099854286346262x7350/60220-2401212301022.3380
BLKH RD EL 300 P 19.5W MS 840 BK4099854286384312x7350/60220-24019.522301152.3380
BLKH RD EL 300 P 19.5W MS 840 WT4099854286407312x7350/60220-24019.522301152.3380
BLKH RD EL SN 250 P 12.5W MS 840 BK4099854286421262x7350/60220-24012.51220972.3380
BLKH RD EL SN 250 P 12.5W MS 840 WT4099854286506262x7350/60220-24012.51220972.3380
BLKH RD EL SN 300 P 20.5W MS 840 BK4099854286520312x7350/60220-24020.523001132.3380
BLKH RD EL SN 300 P 20.5W MS 840 WT4099854286544312x7350/60220-24020.523001132.3380
Model NameEANCCT [K]IPIK[°] Ra[°C]PF[kg]
BLKH RD EL 250 P 12W MS 840 BK40998542862853000/40006510> 800...+35> 0.80.9
BLKH RD EL 250 P 12W MS 840 WT40998542863463000/40006510> 800...+35> 0.80.9
BLKH RD EL 300 P 19.5W MS 840 BK40998542863843000/40006510> 800...+35> 0.91.2
BLKH RD EL 300 P 19.5W MS 840 WT40998542864073000/40006510> 800...+35> 0.91.2
BLKH RD EL SN 250 P 12.5W MS 840 BK40998542864213000/40006510> 800...+35> 0.81.0
BLKH RD EL SN 250 P 12.5W MS 840 WT40998542865063000/40006510> 800...+35> 0.81.0
BLKH RD EL SN 300 P 20.5W MS 840 BK40998542865203000/40006510> 800...+35> 0.91.2
BLKH RD EL SN 300 P 20.5W MS 840 WT40998542865443000/40006510> 800...+35> 0.91.2
ModelCCT [K]** Phi_v [lm]*** Eff. [lm/W]
BLKH RD EL 250 (12W)40001230102
3000116096
BLKH RD EL 250 (11W)4000108098
3000103094
BLKH RD EL 250 (9.5W)400086090
300083088
BLKH RD EL 250 (8.5W)400071084
300068081
BLKH RD EL 300 (19.5W)40002230115
30002130109
BLKH RD EL 300 (17W)40001950114
30001860109
BLKH RD EL 300 (15W)40001660110
30001580106
BLKH RD EL 300 (12.5W)40001360108
30001300103
ModelCCT [K]** Phi_v [lm]*** Eff. [lm/W]
BLKH RD EL SEN 250 (12.5W)4000122097
3000114092
BLKH RD EL SEN 250 (11.5W)4000106092
3000100087
BLKH RD EL SEN 250 (10W)400085086
300080081
BLKH RD EL SEN 250 (9W)400071080
300066074
BLKH RD EL SEN 300 (20.5W)40002300113
30002190107
BLKH RD EL SEN 300 (18W)40002000111
30001900106
BLKH RD EL SEN 300 (15.5W)40001700109
30001620104
BLKH RD EL SEN 300 (13.5W)40001400104
3000132098
Model NameEANBATTERY 1) (h)TEST 2)lmMAINTAINED 3) / NON-MAINTAINED 4)
BLKH RD EL 250 P 12W MS 840 BK4099854286285LiFePO4 - 3hautomatic 5)380Maintained/Non-maintained
BLKH RD EL 250 P 12W MS 840 WT4099854286346LiFePO4 - 3hautomatic 5)380Maintained/Non-maintained
BLKH RD EL 300 P 20W MS 840 BK4099854286384LiFePO4 - 3hautomatic 5)380Maintained/Non-maintained
BLKH RD EL 300 P 20W MS 840 WT4099854286407LiFePO4 - 3hautomatic 5)380Maintained/Non-maintained
BLKH RD EL SN 250 P 13W MS 840 BK4099854286421LiFePO4 - 3hautomatic 5)380Maintained/Non-maintained
BLKH RD EL SN 250 P 13W MS 840 WT4099854286506LiFePO4 - 3hautomatic 5)380Maintained/Non-maintained
BLKH RD EL SN 300 P 21W MS 840 BK4099854286520LiFePO4 - 3hautomatic 5)380Maintained/Non-maintained
BLKH RD EL SN 300 P 21W MS 840 WT4099854286544LiFePO4 - 3hautomatic 5)380Maintained/Non-maintained
Component NameEANØ x h [mm][kg]
LISOEV 250R 8W 830 840 BLKH4099854311918250x380.3
LISOEV 300R 15W 830 840 BLKH4099854311970300x380.4
Component NameEANØ x h [mm][kg]
BLKH RD EYELID 250 BK4099854286759262x740.2
BLKH RD EYELID 250 WT4099854286773262x740.2
BLKH RD EYELID 300 BK4099854286797312x740.2
BLKH RD EYELID 300 WT4099854286810312x740.2

Installation Instructions

Follow these steps for proper installation:

Testing and Operation

Understand the sensor's status indicators and testing procedures.

Control LED Status Indicators ?

Luminaire Status 8)Control LED 7)
Normal 9)Green 10)
Emergency 11)OFF
Testing 12)Green 10) (0.1s, 0.1s, 0.1s ...)
Load failure 13)Red 14) (1s, 1s, 1s ...)
Battery failure 15)Red 14) (1s, 1s, 1s ...)
Charging failure 16)Red 14) (0.1s, 0.1s, 0.1s ...)

Testing Procedures ⚙️

Test ProcedureDuration/ConditionAutomatic Function
Initialization 17)≥ 48h NormalAutomatic 5)
Daily check of Control LED 18)Green 10)
Monthly/Weekly functional test 19) (EN 50172)30 sAutomatic test once every 7 days 20)
Yearly duration test 21) (EN 50172)[3h]Automatic test once every 52 weeks 22)

Detection Area Settings ?

The sensor's detection range, hold time, and daylight sensitivity can be adjusted using DIP switches. Refer to the diagrams for specific settings.

Detection Area Diagrams: Visual representations show the sensor's coverage patterns at various distances and sensitivity levels.

Everloop Components

Specifications for related Everloop components:

Component NameEANØ x h [mm][kg]
LISOEV 250R 8W 830 840 BLKH4099854311918250x380.3
LISOEV 300R 15W 830 840 BLKH4099854311970300x380.4

Bulkhead Eyelid Accessories

Specifications for the Bulkhead Eyelid accessory:

Component NameEANØ x h [mm][kg]
BLKH RD EYELID 250 BK4099854286759262x740.2
BLKH RD EYELID 250 WT4099854286773262x740.2
BLKH RD EYELID 300 BK4099854286797312x740.2
BLKH RD EYELID 300 WT4099854286810312x740.2

Battery Replacement Guide

Detailed steps for replacing the battery:

  1. Step 1: Prepare for battery replacement, noting the battery type (LiFePO4) and expected life (<3h).
  2. Step 2: Access the battery compartment.
  3. Step 3: Disconnect and remove the old battery.
  4. Step 4: Insert the new battery.
  5. Step 5: Reassemble the unit. Ensure the date format DD.MM.YYYY is used for any recording if applicable.

PDF preview unavailable. Download the PDF instead.

elosos1915903 Adobe InDesign 18.0 (Macintosh) GPL Ghostscript 9.55.0

Related Documents

Preview LEDVANCE Bulkhead Combo Installation Guide and Specifications
Detailed installation instructions and technical specifications for the LEDVANCE Bulkhead Combo lighting fixture, including model BLKH CBO RD 325 V 16W MS 840 WT and its accessories.
Preview LEDVANCE BULKHEAD COMBO (SENSOR) Environmental Product Declaration
Environmental Product Declaration for the LEDVANCE BULKHEAD COMBO (SENSOR) luminaire, detailing its environmental impacts, constituent materials, and life cycle stages according to ISO 14025:2006.
Preview LEDVANCE DAMP PROOF MAX Series - Product Specifications and Installation Guide
Detailed product information and installation guide for the LEDVANCE DAMP PROOF MAX series of robust, damp-proof LED luminaires. Includes specifications, assembly steps, and testing procedures.
Preview LEDVANCE Downlight Comfort + Emergency Conversion Box Product Guide
Comprehensive guide to the LEDVANCE Downlight Comfort + Emergency Conversion Box, detailing standard and EM versions, specifications, and installation overview for reliable emergency lighting solutions.
Preview LEDVANCE EU Declaration of Conformity for LN UO EL Luminaires
This document is the EU Declaration of Conformity for LEDVANCE LN UO EL series luminaires, confirming compliance with relevant European Union legislation and harmonized standards. It includes product codes AC71621 and AC71622, detailing their descriptions and the manufacturer's declaration of sole responsibility.
Preview LEDVANCE ENDURA FLOOD SOLAR SENSOR 10W: Installation, Operation & Safety Guide
Comprehensive guide for the LEDVANCE ENDURA FLOOD SOLAR SENSOR 10W, covering installation, operation modes, remote control functions, technical specifications, and important safety warnings regarding battery handling.
Preview LEDVANCE ENDURA® STYLE WALL WIDE SENSOR: Installation Guide and Specifications
Comprehensive guide for installing and using the LEDVANCE ENDURA® STYLE WALL WIDE SENSOR. Includes technical specifications, dimensions, wiring instructions, and safety information.
Preview LEDVANCE EMERGENCY SPOT E 1.3W 3H AT - Technical Data and Installation Guide
Comprehensive technical specifications, installation instructions, and testing procedures for the LEDVANCE EMERGENCY SPOT E 1.3W 3H AT emergency lighting fixture.