LEDVANCE EMERGENCY SPOT E 1.3W 3H AT
Emergency lighting fixture with 3-hour emergency operation.
Product Specifications
EAN | Ø x h (mm) | W | Vac | Hz | Im | K |
---|---|---|---|---|---|---|
4099854230653 | 104 x 66 | 1.3 | 220-240 | 50/60 | 200 | 5700 |
EAN | BATTERY | IP | (°C) | Weight | ||
4099854230653 | 3h | IP20 | 0...+45 | 0.21kg |
A detailed illustration of the LEDVANCE EMERGENCY SPOT E 1.3W 3H AT fixture, showing its compact, recessed design with a flexible cable for connection.
Dimensions
Diagram illustrating the fixture's dimensions: 'a' represents the cutout diameter (Ø 95 mm), 'b' is the outer diameter (Ø 104 mm), 'c' is the mounting depth (5-15 mm), 'd' is the height (43.5 mm), and 'e' and 'f' indicate minimum ceiling clearance requirements (≥ 90 mm).
Label | Dimension |
---|---|
a (Cutout Diameter) | Ø 95 mm |
b (Outer Diameter) | Ø 104 mm |
c (Mounting Depth) | 5-15 mm |
d (Height) | 43.5 mm |
e (Min. Ceiling Clearance) | ≥ 90 mm |
f (Min. Ceiling Clearance) | ≥ 90 mm |
Installation Instructions
- Ensure the power supply is switched OFF at the circuit breaker [Power Switch OFF symbol]. A warning symbol ⚠️ indicates electrical hazard.
- Prepare the ceiling cutout (Ø 95 mm). Insert the fixture into the cutout. Incorrect insertion is indicated by a crossed-out symbol ❌.
- Connect the wiring: The fixture has a brown wire for Live and a blue wire for Neutral. Connect these to the corresponding supply wires.
- Secure the fixture in place, often by rotating it until it locks.
- The fixture is mounted into the ceiling cutout.
- Diagram showing the fixture's internal components or assembly.
- After installation, switch the power supply ON [Power Switch ON symbol] to test the unit.
Testing Procedures
Details on the fixture's testing modes:
Test Type | Description | Procedure | Indicator/Action |
---|---|---|---|
Initialization | ≥ 48h Normal | Automatic 8) | [Battery status indicators] |
Daily check of Control LED | - | - | Green ?️☀️ |
Functional test | 5s | Automatic test once every 7 days or 1x click on test switch for 5-8s 24) | [Test Switch] 10) |
Duration test | [3h] | Automatic test once every 26 weeks or 1x click on test switch for 3-5s 26) | [Test Switch] 10) |
Key Terminology (English)
Explanation of key terms related to the product's operation and testing:
- 1) Battery
- 2) Test
- 3) Maintained
- 4) Non-maintained
- 5) Automatic
- 6) Testing Instructions
- 7) Test switch
- 8) Control LED
- 9) Luminaire Status
- 10) Normal
- 11) Green
- 12) Emergency
- 13) Testing
- 14) Battery connection fault
- 15) Red
- 16) Battery capacity fault
- 17) Luminaire fault
- 18) Initialization
- 19) Daily check of Control LED
- 20) Monthly/Weekly functional test
- 21) Automatic test once every 7 days or 1x click on test switch for 2s
- 22) Yearly duration test
- 23) Automatic test once every 52 weeks or 1x click on test switch for 5s
Certifications and Recycling
The product bears CE, EAC, and UKCA certification marks, indicating compliance with relevant standards. Recycling symbols for paper (PAP), French waste directive (FR), and general recycling (Recicla Al Azul) are also present, with instructions to check local disposal guidelines and points of collection.
Company Information:
LEDVANCE SASU, CQM, 5 rue d'Altorf, 67120 Molsheim France. Website: www.ledvance.com
LEDVANCE Ltd, Sterling House, 810 Mandarin Court, Warrington, Cheshire, WA1 1GG, United Kingdom.