C1FTG30 INSTALL GUIDE
Dimensional Renderings
Detailed diagrams illustrate the physical dimensions and installation requirements for the Coyote C1FTG30 grill.
Diagram Views:
- Top View: Shows the grill's width and depth, gas connection point, and overhang.
- Side View: Shows height and depth.
- Rear View: Shows width.
- Front View: Displays the grill's front profile, including opening heights and widths for installation into cabinetry or islands.
Overall Product Dimensions
Model No. | Height | Width | Depth |
---|---|---|---|
C1FTG30 | 13 1/2" | 30" | 25 1/2" |
CJAKTCS30 | 11" | 32 3/8" | 23" |
Cutout Dimensions for Island
Model No. | Height | Width | Depth |
---|---|---|---|
C1FTG30 | 10 1/4" | 27 1/4" | 20 1/2" |
CJAKTCS30 | 11" | 30 3/4" | 22 1/8" |
Note: When using a Coyote insulated jacket, build your island to the jacket's Cutout and Overall Dimensions. The grill rests on/inside the insulated jacket once installed.
Specifications
Model No. | Gas Supply | BTU's | Regulator | WC Pressure | Max PSI | Electrical Requirements |
---|---|---|---|---|---|---|
C1FTGLP | Propane | 34,000 | 20 lb Tank Regulator | 11" | .5 PSI | Qty 1 - 120 VAC 60 Hz Grounded Plug |
C1FTGNG | Natural Gas | 34,000 | 1/2" Female Pipe | 4" | .5 PSI | Qty 1 - 120 VAC 60 Hz Grounded Plug |
Installation Requirements
Non-Combustible Construction
An insulated jacket is NOT required for non-combustible construction.
Diagram Descriptions:
- Top View: Illustrates the required opening dimensions, gas connection location, and grill overhang for installation.
- Front View: Shows the necessary opening height, width for doors/drawers, and overall opening height including the countertop.
Key Requirements:
- Combustible material must be kept at least 12 inches away from the grill frame in all directions (horizontal & vertical).
- The grill is designed to hang from the countertop with no under-support.
- A minimum rear clearance of 7 inches is required to the wall/partition behind the grill for exhaust ventilation.
Combustible Construction
An insulated jacket IS REQUIRED for combustible construction (Model # CJAKTCS30).
Diagram Descriptions:
- Top View: Details the opening dimensions, gas connection, and grill overhang when using the insulated jacket.
- Front View: Shows the required opening height, width for doors/drawers, and overall opening height, ensuring proper fit with the insulated jacket.
Key Requirements:
- If using combustible material within 12 inches of the grill frame, the corresponding Coyote Insulated Jacket must be used.
- Using an insulated jacket does not exempt users from other standard installation procedures (e.g., ventilation, connections).
- The jacket is designed to hang from the countertop with no under-support.
- A minimum rear clearance of 7 inches is required to the wall/partition behind the grill for exhaust ventilation.
Ventilation Requirements
Proper ventilation is crucial for safe operation. Ensure the following:
- Include at least two vents within the island, each with a minimum area of 20 square inches.
- These vents must allow fresh air to move from the grill cabinet to the exterior environment.
- For propane setups, install vents lower in the island as propane is heavier than air.
- For natural gas setups, install vents higher in the island as natural gas is lighter than air.
- Do not place both vents on the same wall; cross-ventilation is essential for dissipating excess heat or trapped gas.
Important Note to Installer: This document is not a substitute for the Owner's Manual, which contains specific safety requirements and consumer guidelines. Please refer to your Owner's Manual prior to installing or operating your built-in grill.