Coyote C-series 42-Inch 5-Burner Built-In Gas Grill

PDF preview unavailable. Download the PDF instead.

Coyote-C-series-42-Inch-5-Burner-Built-In-Gas-Grill-Install-Guide
C2C42 INSTALL GUIDE
DIMENSIONAL RENDERINGS

Overall Product Dimensions

Model No. C2C42
CJAKTCS42

Height 23" 11"

Width 42 1/2" 44 1/8"

Depth 25 1/2"
23"

Cutout Dimensions for Island

Model No. C2C42
CJAKTCS42

Height 10 1/4"
11"

Width 39 1/2" 42 1/4"

Depth 20 1/2" 22 1/8"

 When using a Coyote insulated jacket, you will want to build your island to the jackets Cutout and Overall Dimensions listed above. Once the jacket is installed, the grill will rest on/inside the insulated jacket

Model No. C2C42LP C2C42NG

Gas Supply BTU's

Regulator

WC Pressure Max PSI

Propane 100,000 20 lb Tank Regulator

11"

.5 PSI

Natural Gas 100,000 1/2" Female Pipe

4"

.5 PSI

Electrical Requirements ty 1 - 120 VAC 0 Hz Grounded Plug ty 1 - 120 VAC 0 Hz Grounded Plug

Important Note to Installer: This file is not intended to replace your Owners' Manual which contains specific safety requirements and consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in grill.

www.coyoteoutdoor.com

C2C42 INSTALL GUIDE

NON-COMBUSTIBLE CONSTRUCTION
Insulated Jacket NOT Required

COMBUSTIBLE CONSTRUCTION
Insulated Jacket Required - Model # CJAKTCS42

1 1/2"

TOP VIEW

GRILL OPENING

1 5/8"

24"

24"

2 1/2"

G

24"

20 1/2" OPENING
DEPTH

GAS CONNECTION
2 1/2"

1 1/2" GRILL OVERHANG

TOP VIEW

LINER OPENING

7/8" 1 3/4"

221/8" OPENING
DEPTH

4 1/8"

G

GAS CONNECTION

4 1/8"

7/8" JACKET OVERHANG

10 1/4" OPENING HEIGHT
INCLUDING COUNTERTOP

39 1/2" OPENING WIDTH
21/2" 2" G

1 1/2" MIN

DOORS / DRAWERS OPENING WIDTH

OPENING HEIGHT

11" OPENING HEIGHT
INCLUDING COUNTERTOP

42 1/4" OPENING WIDTH
4 1/8" 2 3/4" G

1 1/2" MIN

DOORS / DRAWERS OPENING WIDTH

OPENING HEIGHT

FRONT VIEW  Combustible material can not be within 24" of the grills frame  This applies to all directions - horizontal & vertical  Shaded area above on "TOP VIEW" illustrates the 24" minimum
requirement (not to scale for rendering purposes)  The grill is designed to hang from the counter top with no support
underneath  Minimum rear clearance for the hood to open is 2"  If you have a wall/partition behind the grill, the minimum rear clearance
to that wall should be at least 7" to allow for ventilation of the exhaust

FRONT VIEW  If using combustible material within 24" of the grill frame, you MUST use
the corresponding Coyote Insulated Jacket  Using a insulated jacket, does not waive any other standard installation
procedure (ventilation, connections, etc)  The jacket is designed to hang from the counter top with no support
underneath  Minimum clearance for hood to open is 2"  If you have a wall/partition behind the grill, the minimum rear clearance
to that wall should be at least 7" to allow for ventilation of the exhaust

Ventilation Requirements:  Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within
the island.  These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.  For a propane setup, the vents should be installed lower as propane is heavier than air.  For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.  Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped
gas to dissipate.
Important Note to Installer: This file is not intended to replace your Owners' Manual which contains specific safety requirements and consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in grill.

www.coyoteoutdoor.com


GPL Ghostscript 9.52 Adobe InDesign CC 2015 (Macintosh)