Approved Acuity Dimming Systems
Electronic Low Voltage - Reverse Phase Dimming
Dimmable using Acuity nLight dimming controls when combined with an nLight nPP PCD EFP ELV or rPP PCD EFP G2 ELV Phase Adaptive Power Pack at the track input. Dimming range of 100% down to as low as 1% typical* with a minimum load of one fixture and maximum load of 1920W @ 120VAC.
*Typical dimming range based on laboratory evaluation - actual installation conditions and results may vary.
Approved Acuity & Non-Acuity Dimming Methods
Incandescent and Magnetic Low Voltage - Forward Phase Dimming
Dimmable with the use of most forward phase dimmers. Dimming range of 100% down to as low as 2% with a minimum load of one fixture and a maximum load of 50% of the dimmer rated load (see example); both dimming range and maximum rated load may vary depending on dimmer model.
Example: Fixture Rating = 24W
Dimmer Rating = 600W
Equivalent Incandescent Load (EIL) = 50%
(600/24W) X 0.5 = 12 Fixtures per Dimmer
Manuf. | Product Family | Series | Type | Min Light (%) |
---|---|---|---|---|
Acuity | Synergy | ISD 600 LV | MLV | 9 |
Acuity | Synergy | ISD 1000 LV | INC | 7 |
Acuity | Synergy | ISD 600 I | INC | 10 |
Acuity | Synergy | ISD 1000 I | INC | 8 |
Control4 | FP Wall Dimmer | C4-FPD 120* | MLV | 2 |
Insteon | Keypad Dimmer | 2334-232* | INC | 2 |
Insteon | Dimmer Switch | 2477D* | INC | 2 |
Insteon | Dimmer Micro Module | 2442-222* | INC | 2 |
Leviton | SureSlide | 6613-PLW* | MLV | 2 |
Leviton | IllumaTech | IPL06-10Z* | INC | 2 |
Leviton | SureSlide | 6633* | INC | 2 |
Lutron | Maestro | MA* | INC | 2 |
Lutron | RadioRA | 2 6D* | INC | 2 |
Lutron | RadioRA | 2 10ND* | INC | 2 |
Lutron | Diva | DVCL-153P* | INC | 2 |
Lutron | Glyder | GLV* | MLV | 3 |
Lutron | Rotary | D* | INC | 2 |
Lutron | Diva | DVLV | MLV | 6 |
Lutron | Nova T | NT* | INC | 2 |
Lutron | Diva | DV* | INC | 2 |
Lutron | Skylark | SLV* | MLV | 4 |
*Juno recommended dimmers |
Electronic Low Voltage - Reverse Phase Dimming
Dimmable with the use of most electronic low voltage dimmers. Electronic low voltage dimmers require a neutral wire in the wall box. Dimming range of 100% down to as low as 2% with a minimum load of one fixture and a maximum load of 75% of the dimmer rated load (see example); both dimming range and maximum rated load may vary depending on dimmer model.
Example: Fixture Rating = 24W
Dimmer Rating = 600W
Equivalent Incandescent Load (EIL) = 75%
(600/24W) X 0.75 = 18 Fixtures per Dimmer
Manuf. | Product Family | Series | Type | Min Light (%) |
---|---|---|---|---|
Control4 | Adaptive Phase Dimmer | C4-APD 120* | PHA | 2 |
Leviton | Vizia | VPE06-1LX* | ELV | 3 |
Leviton | Illumatech | IPE04* | ELV | 4 |
Lutron | Nova T | NTELV | ELV | 6 |
Lutron | Diva | DVELV* | ELV | 2 |
Lutron | Maestro | MAELV* | ELV | 5 |
Lutron | RadioRA2 | RRD-6NA* | PHA | 2 |
Lutron | Power Module | PHPM-PA-120* | PHA | 2 |
*Juno recommended dimmers |
Integrated Control Systems
Manuf. | Product Family | Series | Type | Min Light (%) |
---|---|---|---|---|
Acuity | nLight | nPP PCD EFP ELV* | ELV | 1 |
Acuity | nLight | rPP PCD EFP ELV* | ELV | 1 |
Lutron | LP | LP-RPM-4U* | MLV | 2 |
Lutron | LP | LP-RPM-4A* | PHA | 2 |
Lutron | GRAFIK EYE | QSGRJ-3P* | MLV | 2 |
*Juno recommended dimmers |