INSTALLATION MANUAL

MYALARM2 Rev4

Remote control GSM/GPRS advanced device

MODULE LAYOUT

CASE DIMENSIONS

Dimensions: 108 mm (height) x 80 mm (width) x 8 mm (depth) x 32 mm (thickness)

Weight: 150 g

Case Material: Polycarbonate / ABS

SYMBOLS ON THE ENCLOSURE

  • ON / OFF power button
  • GPS antenna
  • Menu access button
  • SIM Slot for mini SIM
  • SD Slot for micro SD card
  • Micro USB connector

SIGNALS VIA LED ON FRONT PANEL

LED STATUS LED meaning
GSM (Yellow) Slow flashing The device is connected to the GSM network
Fast flashing GSM network search / no signal / GPRS connection
PWR (Green) ON Device ON
OFF Device OFF
Fast flashing Access to micro SD card
Medium flashing Device in datalogger function

PRELIMINARY WARNINGS

WARNING indicates conditions or actions that put the user's safety at risk.

ATTENTION indicates conditions or actions that might damage the instrument or the connected equipment.

The warranty becomes null and void in the event of improper use or tampering with the module or devices supplied by the manufacturer, or if the instructions contained in this manual are not followed.

TECHNICAL SPECIFICATIONS

GPS CARD SPECIFICATIONS (OPTION)

RELAY EXPANSION CARD SPECIFICATIONS (OPTIONAL)

INITIAL POWERING ON OF THE DEVICE

MyAlarm2 is supplied in “shipping mode”. This mode prevents any unnecessary discharge of the battery during transport as well as any accidental switch-ons.

To exit this mode, simply power the device via the cable supplied.

N.B.: During "shipping mode” the power button is disabled.

ON/OFF BUTTON AND SCROLL DISPLAY BUTTON

The device is equipped with a PWR button located on the top left side (front panel view). Pressing this button turns the module on and off. To switch it off, hold the PWR key down for a few seconds.

The device is also equipped with a SCR button, located on the top right side (front panel view). Pressing this key displays the parameters.

[PWR Button] [ANTENNA] [SCR Button]

MICRO USB PORT AND POWER SUPPLY

The device has a micro USB connector on the left side of its enclosure, which can be used for configuration, firmware updates and to recharge the internal battery.

To recharge the internal battery, use:

Power supply through the USB jack is not suitable for fixed installations, or configurations where relays and/or digital inputs are used.

[Micro USB Port] [ANTENNA]

AUTO POWER-OFF

If the display shows “LOW BAT”, it means that the internal battery is low, after 60 seconds the device switches off automatically.

To restore the battery charge to an appropriate value, recharge the device using one of the recommended modes.

INSERTING THE SIM CARD AND SD CARD

INSERTING THE SIM CARD

MyAlarm2 has a slot for mini SIM located in the right side of the enclosure. To insert the card in its corresponding slot, make sure the metal contacts are facing right (as seen in the figure).

[SIM card slot]

INSERTING THE SD CARD

MyAlarm2 is equipped with an SD card input that can be used to update the device's firmware and the information and connection parameters with the world's best known telephony operators. Note: DO NOT REMOVE THE CONTENT OF THE SD CARD PROVIDED. THIS MAY RESULT IN FAILED DATA CONNECTION WITH THE SERVICE.

MyAlarm2. The input for micro SD card is located on the right side of the enclosure. To insert the SD card in its corresponding slot, make sure the metal contacts are facing right (as seen in the figure).

[SD card slot]

ASSEMBLY REGULATIONS

The device has been designed for vertical installation or on a DIN IEC EN 60715 omega rail. Avoid mounting the device inside metal cabinets or on top of heat-generating equipment.

INSTALLATION ON DIN IEC EN 60715 RAIL AND WALL FIXING

1. Insert the hooks of the support for DIN IEC EN 60715 rail into the corresponding slots on the back of the container.

2. Hook the support to the DIN IEC EN 60715 rail.

Alternatively:

1. Through the two holes on the support for DIN IEC EN 60715 rail it is possible to fix it to the wall with the two anchors supplied.

2. MyAlarm2 can be fixed to the support by inserting the hooks of the support into the slots on the back.

[Diagram of DIN rail mounting]

ASSEMBLY RULES FOR VERSION WITH GPS (OPTIONAL)

For optimal reception of the GPS signal given by the satellites, MyAlarm2 should be positioned in an area not covered by metal structures. If this is not possible or if the satellite reception is no good, an optional external antenna with 3m cable (code A-GPS) is available. Follow the procedure supplied with the package for the installation of the external antenna.

SAFETY INFORMATION

MyAlarm2 has a terminal block inside its enclosure. To access the internal terminal block of the device, unscrew the screw at the centre of the black cover positioned at the bottom of the enclosure and lift up. In the side figure, the cover has been removed.

IMPORTANT: With the relay card, mobile wiring of cables connected to terminals is not permitted. To make the cables from the terminals safe, use the break-out passages in the back of the enclosure. When the wiring is complete, fasten the protective cover on the device with the screw to prevent any accidental contact.

[Diagram of terminal block with connections]

ELECTRICAL CONNECTIONS

INSERTION AND EXTRACTION FROM TERMINALS WITH A PUSH-WIRE CONNECTION

Insertion of a rigid cable: [Press down] then [insert cable]. Recommended stripping: 8-9 mm.

Insertion of a thin cable: A: press with a screwdriver, B: insert the cable.

Extraction of a rigid cable: A: press with a screwdriver, B: extract the cable.

PUSH-WIRE TERMINAL BLOCK

KEY:

Terminal Block Diagram:

1: Digital output 1, relay N.O. (*) (Available with the relay board (optional))

2: Common to the two relays (*)

3: Digital output 2, relay N.O. (*)

4: Digital Input 1

5: Digital Input 2

6: Digital Input 3

7: Digital Input 4

8: 12 Vdc output (50 mA max)

9: Ground

10: Analogue input 1

11: Analogue input 2

12: Ground

13: Input for NTC external sensor

Power supply 6-15 Vdc(**)

Ground

(**) Tip: connect a 1 A protection fuse.

DISPLAY FUNCTIONS AND USE

The main MyAlarm2 display page provides the following information:

[Display showing OFF status for GSM, OUT 1, OUT 2, IN 1, IN 2, IN 3, IN 4, and battery level]

A - GSM signal level

B - output 1 status

C - output 2 status

D - digital input 1 status

E - digital input 2 status

F - digital input 3 status

G - digital input 4 status

H - battery level

To change the page on the display, use the SCR key as shown in the “INITIAL POWERING” paragraph.

By holding the PWR key for a few seconds you will have access to the main menu:

POWER OFF

UNMOUNT SD

CANCEL

To choose the desired command use the SCR key which allows you to scroll through the various options, to confirm the desired option press the PWR key.

It is also possible to call up the contextual menu of a page by holding down the SCR key for a few seconds. Through a contextual menu it is possible to display other sub-pages and / or information. Pages with contextual menus are identifiable by a triangle in the display top right corner.

PRODUCT ID CODE

A label will be applied to the product packaging that allows you to recognize the model purchased. Find below the meaning of the codes applied to the packaged instrument:

MY2-BSG-0R-0W-M -BG

EQUIPMENT NAME

MODEL: B: BASIC, S: SECURITY, G: GPS

RELAY: 0: ABSENT, R: PRESENT

RADIO: 0: ABSENT, W: PRESENT

TERMINALS: G: PRESENT

COLOUR: B: BLUE, G: PRESENT

ACCESSORIES

CODE DESCRIPTION
A-GPS External GPS antenna with 3 m cable
A-GSM/QUAD-N External GSM / QUAND-N antenna with 5 m cable
EXTERNAL NTC THERMISTOR

CONTACT INFORMATION

Technical support: support@seneca.it

Product information: sales@seneca.it

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The content of this document corresponds to the described products and technologies. Stated data may be modified or supplemented for technical and/or sales purposes.

Models: MYALARM2 Rev4 Remote Control GSM-GPRS Advanced Device, MYALARM2, Rev4 Remote Control GSM-GPRS Advanced Device, Control GSM-GPRS Advanced Device, GSM-GPRS Advanced Device, Advanced Device, Device

File Info : application/pdf, 8 Pages, 915.05KB

PDF preview unavailable. Download the PDF instead.

MY2B-X-X-M-G-Installation-Guide-en

References

Adobe PDF Library 15.0 Adobe InDesign 15.0 (Macintosh)

Related Documents

Preview Manual de Instalación MyAlarm3 Cloud - SENECA
Guía completa de instalación y configuración para el sistema de monitorización remota MyAlarm3 Cloud de SENECA. Incluye especificaciones técnicas, conexiones, gestión Cloud y solución de problemas.
Preview MyAlarm3 Cloud Installation Manual
Installation manual for the Seneca MyAlarm3 Cloud, an intelligent remote monitoring control unit. Covers product description, setup, electrical connections, cloud service activation, GPS and NTC probe installation, and troubleshooting.
Preview T201DC100 DC Current Transducer Installation Manual
Installation manual for the SENECA T201DC100 DC current transducer, covering preliminary warnings, module schematics, technical specifications, electrical connections, and DIP switch configurations.
Preview SENECA T201DC100 Installation Manual
Installation manual for the SENECA T201DC100 AC/DC current transducer, detailing technical specifications, electrical connections, and usage instructions.
Preview SENECA T201DC100 Installation Manual and Technical Specifications
This document provides comprehensive installation instructions, technical specifications, and usage guidelines for the SENECA T201DC100 DC current transducer. It covers electrical connections, module layout, safety precautions, and performance data for industrial applications.
Preview SENECA R-KEY-LT / R-KEY-LT-P Installation Manual
Installation manual for SENECA R-KEY-LT and R-KEY-LT-P industrial gateways, detailing module layout, LED signals, device configuration, technical specifications, DIP-switch settings, and electrical connections.
Preview SENECA R-KEY-LT / R-KEY-LT-P Installation Manual - Industrial Gateway
Comprehensive installation manual for SENECA R-KEY-LT and R-KEY-LT-P industrial gateways. Covers setup, configuration, technical specifications, and electrical connections.
Preview Manuel d'installation T201DC100 de SENECA | Guide d'installation et spécifications techniques
Découvrez le manuel d'installation complet pour le transducteur de courant SENECA T201DC100. Ce guide fournit des instructions détaillées, des avertissements de sécurité et des spécifications techniques pour une installation correcte.