MEAN WELL HRPG-200 Series 200W Single Output Power Supply

Key Features

Specifications

GTIN CODE: Search MEAN WELL products at www.meanwell.com/serviceGTIN.aspx.

MODELHRPG-200-3.3HRPG-200-5HRPG-200-7.5HRPG-200-12HRPG-200-15HRPG-200-24HRPG-200-36HRPG-200-48
DC VOLTAGE3.3V5V7.5V12V15V24V36V48V
RATED CURRENT40A35A26.7A16.7A13.4A8.4A5.7A4.3A
CURRENT RANGE0 ~ 40A0 ~ 35A0 ~ 26.7A0 ~ 16.7A0 ~ 13.4A0 ~ 8.4A0 ~ 5.7A0 ~ 4.3A
RATED POWER132W175W200.3W200.4W201W201.6W205.2W206.4W
RIPPLE & NOISE (max.) Note.280mVp-p90mVp-p100mVp-p120mVp-p150mVp-p150mVp-p250mVp-p250mVp-p
VOLTAGE ADJ. RANGE2.8 ~ 3.8V4.3 ~ 5.8V6.8 ~ 9V10.2 ~ 13.8V13.5 ~ 18V21.6 ~ 28.8V28.8 ~ 39.6V40.8 ~ 55.2V
VOLTAGE TOLERANCE Note.3±2.0%±2.0%±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%±0.3%±0.3%±0.2%±0.2%±0.2%
LOAD REGULATION±1.5%±1.0%±1.0%±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE TIME1000ms, 50ms/230VAC; 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)16ms/230VAC; 16ms/115VAC at full load
VOLTAGE RANGE Note.585 ~ 264VAC; 120 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.95/230VAC; PF>0.99/115VAC at full load
EFFICIENCY (Typ.)80%84%86%88%88%88%89%89%
AC CURRENT (Typ.)2.1A/115VAC; 1.1A/230VAC
INRUSH CURRENT (Typ.)35A/115VAC; 70A/230VAC
LEAKAGE CURRENT<1.2mA / 240VAC

Protections

Overload: 105 ~ 135% rated output power. Protection type: Constant current limiting, recovers automatically after fault condition is removed.

Over Voltage: Protection type: Shut down o/p voltage, re-power on to recover.

Over Temperature: Shut down o/p voltage, recovers automatically after temperature goes down.

Functions

5V Standby: 5VSB: 5V@0.3A; tolerance ±5%, ripple: 50mVp-p (max.).

Remote Control: RC+/RC-: 4~10V or open = power on; 0~0.8V or short = power off.

Environmental Specifications

Working Temperature: -40 ~ +70°C (Refer to Derating Curve).

Working Humidity: 20 ~ 90% RH non-condensing.

Storage Temperature, Humidity: -40 ~ +85°C, 10 ~ 95% RH.

Temperature Coefficient: ±0.03%/°C (0 ~ 50°C).

Vibration: 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes.

Safety & EMC

Safety Standards: UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved.

Safety & Withstand Voltage: I/P-O/P: 3KVAC, I/P-FG: 2KVAC, O/P-FG: 0.5KVAC.

Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25°C / 70% RH.

EMC Emission: Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020.

EMC Immunity: Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020.

Other Specifications

MTBF: 1612.1K hrs min. (Telcordia SR-332); 189.1K hrs min. (MIL-HDBK-217F at 25°C).

Dimension: 199mm x 98mm x 38mm (L*W*H).

Packing: 0.77Kg; 18pcs/14.9Kg/0.87CUFT.

Notes

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (available at www.meanwell.com//Upload/PDF/EMI_statement_en.pdf).
  5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. No load power consumption < 0.5W when RC+ & RC- (CN100 pin1,2) is 0 ~ 0.8V or short.
  7. The ambient temperature derating of 3.5°C/1000m for fanless models and 5°C/1000m for fan models for operating altitude higher than 2000m (6500ft).

Product Liability Disclaimer: For detailed information, please refer to www.meanwell.com/serviceDisclaimer.aspx.

Mechanical Specification

(Unit: mm, tolerance ± 1mm)

Terminal Pin Assignment

Pin No.AssignmentPin No.Assignment
1AC/L4,5DC OUTPUT -V
2AC/N6,7DC OUTPUT +V
3FG

CN100 Connector Pin Assignment

Connector: HRS DF11-6DP-2DS or equivalent

Pin No.AssignmentMating HousingTerminal
1RC+HRS DF11-6DS or equivalent
2RC-
3AUX
4AUXGHRS DF11-**SC or equivalent
5+S
6-S

The unit has overall dimensions of 199mm x 98mm x 38mm (Length x Width x Height). Mounting is facilitated by four M3 screws.

Block Diagram

The block diagram illustrates the internal architecture of the HRPG-200 series power supply. It shows the signal flow starting from the AC input, passing through an EMI filter, active inrush current limiting, and a PFC (Power Factor Correction) stage. This is followed by power switching, rectification, and filtering for the main DC output. Auxiliary power is also generated. Detection circuits for Over Temperature Protection (OTP), Overload Protection (OLP), and Over Voltage Protection (OVP) are integrated. Control signals for PFC and PWM are managed, along with Remote Control and Remote Sense functionalities.

Derating Curves

Ambient Temperature Derating Curve

This curve shows the relationship between ambient temperature and the maximum allowable load percentage. The power supply can operate at 100% load from -40°C up to approximately 50°C. Beyond 50°C, the maximum load capacity decreases linearly, reaching 0% load at 70°C.

Output Derating VS Input Voltage

This curve illustrates the load percentage versus input voltage at 60Hz. The power supply operates at 100% load from 85VAC up to approximately 135VAC. As the input voltage increases from 135VAC to 264VAC, the maximum allowable load decreases linearly, reaching 0% load at 264VAC.

Function Manual

CN100 Pin Description

Remote Control Operation

The PSU can be turned ON/OFF using the "Remote ON/OFF" function by connecting Pin 1 (RC+) and Pin 2 (RC-).

Diagram Description: A simple circuit shows the RC+ and RC- pins connected to a switch. When the switch is closed (short), the output is OFF. When the switch is open, the output is ON.

Remote Sense Function

The remote sensing feature compensates for voltage drop on the load wiring, up to 0.5V. It requires connecting the +S and -S pins (Pin 5 and Pin 6) directly to the positive and negative terminals of the load, respectively. It is recommended to twist the sense wires (+S and -S) together to minimize noise interference.

Diagram Description: A diagram shows the +S and -S pins connected to the positive and negative terminals of the load, respectively. The sense lines are depicted as twisted pairs.

Models: HRPG-200 Series Single Output with PFC Function, HRPG-200 Series, Single Output with PFC Function, Output with PFC Function, PFC Function, Function

File Info : application/pdf, 3 Pages, 123.52KB

PDF preview unavailable. Download the PDF instead.

HRPG-200-SPEC

References

Acrobat Distiller 9.0.0 (Windows)

Related Documents

Preview MEAN WELL HRPG-300 Series 300W Single Output PFC Power Supply Datasheet
Detailed technical specifications, features, mechanical dimensions, and functional descriptions for the MEAN WELL HRPG-300 series 300W single output AC/DC power supplies with active PFC. Includes electrical characteristics, protections, and environmental data.
Preview MEAN WELL HRPG-1000N3 Series: 1000W Ultra-High Peak Power Supply Datasheet
Detailed specifications, features, applications, and functional descriptions for the MEAN WELL HRPG-1000N3 series of 1000W ultra-high peak power supplies. Includes technical data, block diagrams, and connection details for industrial applications.
Preview MEAN WELL LRS-200 Series 200W Single Output Power Supply Datasheet
Comprehensive datasheet for the MEAN WELL LRS-200 Series 200W single output enclosed power supply, detailing features, applications, electrical specifications, dimensions, and safety compliance.
Preview MEAN WELL UHP-200 Series 200W Slim Type PFC Switching Power Supply
Comprehensive technical specifications, features, applications, and installation guidelines for the MEAN WELL UHP-200 series 200W slim type, fanless switching power supply with active PFC, suitable for various industrial applications.
Preview MEAN WELL LRS-200 Series 200W Single Output Switching Power Supply Specifications
Comprehensive technical specifications for the MEAN WELL LRS-200 series 200W single output switching power supplies. Details include electrical characteristics, features, applications, environmental specifications, safety compliance, and mechanical dimensions for models ranging from 3.3V to 48V.
Preview MEAN WELL LRS-200 Series 200W Single Output Switching Power Supply Datasheet
Comprehensive technical datasheet for the MEAN WELL LRS-200 series of 200W single-output enclosed switching power supplies. This document details features, applications, electrical specifications, environmental conditions, safety compliance, block diagrams, derating curves, static characteristics, and mechanical dimensions for models LRS-200-3.3 through LRS-200-48.
Preview MEAN WELL LRS-200 Series 200W Single Output Switching Power Supply Specifications
Detailed specifications for the MEAN WELL LRS-200 series of 200W single-output enclosed switching power supplies. Features include wide AC input range, high efficiency, low no-load power consumption, and compliance with international safety standards. Ideal for industrial automation, control systems, and electronic equipment.
Preview MEAN WELL LRS-200 Series 200W Single Output Switching Power Supply
Detailed specifications and features for the MEAN WELL LRS-200 series, a 200W single-output enclosed switching power supply. Covers applications in industrial automation, control systems, and electronic equipment, with features like wide input range, high efficiency, low no-load power consumption, and robust protection.