MEAN WELL HRPG-200 Series 200W Single Output Power Supply
Key Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 89%
- Withstands 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- 1U low profile 38mm height
- Built-in remote ON-OFF control
- Standby 5V@0.3A
- Built-in remote sense function
- No load power consumption < 0.5W (Note 6)
- 5 years warranty
Specifications
GTIN CODE: Search MEAN WELL products at www.meanwell.com/serviceGTIN.aspx.
MODEL | HRPG-200-3.3 | HRPG-200-5 | HRPG-200-7.5 | HRPG-200-12 | HRPG-200-15 | HRPG-200-24 | HRPG-200-36 | HRPG-200-48 |
---|---|---|---|---|---|---|---|---|
DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 40A | 35A | 26.7A | 16.7A | 13.4A | 8.4A | 5.7A | 4.3A |
CURRENT RANGE | 0 ~ 40A | 0 ~ 35A | 0 ~ 26.7A | 0 ~ 16.7A | 0 ~ 13.4A | 0 ~ 8.4A | 0 ~ 5.7A | 0 ~ 4.3A |
RATED POWER | 132W | 175W | 200.3W | 200.4W | 201W | 201.6W | 205.2W | 206.4W |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 90mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 250mVp-p | 250mVp-p |
VOLTAGE ADJ. RANGE | 2.8 ~ 3.8V | 4.3 ~ 5.8V | 6.8 ~ 9V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 28.8 ~ 39.6V | 40.8 ~ 55.2V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
LOAD REGULATION | ±1.5% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
SETUP, RISE TIME | 1000ms, 50ms/230VAC; 2500ms, 50ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 16ms/230VAC; 16ms/115VAC at full load | |||||||
VOLTAGE RANGE Note.5 | 85 ~ 264VAC; 120 ~ 370VDC | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC; PF>0.99/115VAC at full load | |||||||
EFFICIENCY (Typ.) | 80% | 84% | 86% | 88% | 88% | 88% | 89% | 89% |
AC CURRENT (Typ.) | 2.1A/115VAC; 1.1A/230VAC | |||||||
INRUSH CURRENT (Typ.) | 35A/115VAC; 70A/230VAC | |||||||
LEAKAGE CURRENT | <1.2mA / 240VAC |
Protections
Overload: 105 ~ 135% rated output power. Protection type: Constant current limiting, recovers automatically after fault condition is removed.
Over Voltage: Protection type: Shut down o/p voltage, re-power on to recover.
Over Temperature: Shut down o/p voltage, recovers automatically after temperature goes down.
Functions
5V Standby: 5VSB: 5V@0.3A; tolerance ±5%, ripple: 50mVp-p (max.).
Remote Control: RC+/RC-: 4~10V or open = power on; 0~0.8V or short = power off.
Environmental Specifications
Working Temperature: -40 ~ +70°C (Refer to Derating Curve).
Working Humidity: 20 ~ 90% RH non-condensing.
Storage Temperature, Humidity: -40 ~ +85°C, 10 ~ 95% RH.
Temperature Coefficient: ±0.03%/°C (0 ~ 50°C).
Vibration: 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes.
Safety & EMC
Safety Standards: UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved.
Safety & Withstand Voltage: I/P-O/P: 3KVAC, I/P-FG: 2KVAC, O/P-FG: 0.5KVAC.
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25°C / 70% RH.
EMC Emission: Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020.
EMC Immunity: Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020.
Other Specifications
MTBF: 1612.1K hrs min. (Telcordia SR-332); 189.1K hrs min. (MIL-HDBK-217F at 25°C).
Dimension: 199mm x 98mm x 38mm (L*W*H).
Packing: 0.77Kg; 18pcs/14.9Kg/0.87CUFT.
Notes
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (available at www.meanwell.com//Upload/PDF/EMI_statement_en.pdf).
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- No load power consumption < 0.5W when RC+ & RC- (CN100 pin1,2) is 0 ~ 0.8V or short.
- The ambient temperature derating of 3.5°C/1000m for fanless models and 5°C/1000m for fan models for operating altitude higher than 2000m (6500ft).
Product Liability Disclaimer: For detailed information, please refer to www.meanwell.com/serviceDisclaimer.aspx.
Mechanical Specification
(Unit: mm, tolerance ± 1mm)
Terminal Pin Assignment
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | AC/L | 4,5 | DC OUTPUT -V |
2 | AC/N | 6,7 | DC OUTPUT +V |
3 | FG |
CN100 Connector Pin Assignment
Connector: HRS DF11-6DP-2DS or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | RC+ | HRS DF11-6DS or equivalent | |
2 | RC- | ||
3 | AUX | ||
4 | AUXG | HRS DF11-**SC or equivalent | |
5 | +S | ||
6 | -S |
The unit has overall dimensions of 199mm x 98mm x 38mm (Length x Width x Height). Mounting is facilitated by four M3 screws.
Block Diagram
The block diagram illustrates the internal architecture of the HRPG-200 series power supply. It shows the signal flow starting from the AC input, passing through an EMI filter, active inrush current limiting, and a PFC (Power Factor Correction) stage. This is followed by power switching, rectification, and filtering for the main DC output. Auxiliary power is also generated. Detection circuits for Over Temperature Protection (OTP), Overload Protection (OLP), and Over Voltage Protection (OVP) are integrated. Control signals for PFC and PWM are managed, along with Remote Control and Remote Sense functionalities.
Derating Curves
Ambient Temperature Derating Curve
This curve shows the relationship between ambient temperature and the maximum allowable load percentage. The power supply can operate at 100% load from -40°C up to approximately 50°C. Beyond 50°C, the maximum load capacity decreases linearly, reaching 0% load at 70°C.
Output Derating VS Input Voltage
This curve illustrates the load percentage versus input voltage at 60Hz. The power supply operates at 100% load from 85VAC up to approximately 135VAC. As the input voltage increases from 135VAC to 264VAC, the maximum allowable load decreases linearly, reaching 0% load at 264VAC.
Function Manual
CN100 Pin Description
- Pin 1 (RC+): Controls the output ON/OFF via electrical or dry contact with Pin 2 (RC-). Short circuit: Power OFF; Open circuit: Power ON.
- Pin 2 (RC-): Remote control ground.
- Pin 3 (AUX): Auxiliary voltage output (4.75~5.25V), referenced to Pin 4 (AUXG). Maximum load current is 0.3A. This output is not affected by the "remote ON/OFF control".
- Pin 4 (AUXG): Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
- Pin 5 (+S): Positive sensing. Connect to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up. Maximum line drop compensation is 0.5V.
- Pin 6 (-S): Negative sensing. Connect to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up. Maximum line drop compensation is 0.5V.
Remote Control Operation
The PSU can be turned ON/OFF using the "Remote ON/OFF" function by connecting Pin 1 (RC+) and Pin 2 (RC-).
- SW ON (Short between RC- and RC+): Output OFF
- SW OFF (Open between RC- and RC+): Output ON
Diagram Description: A simple circuit shows the RC+ and RC- pins connected to a switch. When the switch is closed (short), the output is OFF. When the switch is open, the output is ON.
Remote Sense Function
The remote sensing feature compensates for voltage drop on the load wiring, up to 0.5V. It requires connecting the +S and -S pins (Pin 5 and Pin 6) directly to the positive and negative terminals of the load, respectively. It is recommended to twist the sense wires (+S and -S) together to minimize noise interference.
Diagram Description: A diagram shows the +S and -S pins connected to the positive and negative terminals of the load, respectively. The sense lines are depicted as twisted pairs.