Key Features
- Slim and Low profile (26mm)
- Fanless design, 200W convection cooling
- Withstands 300VAC surge input for 5 seconds
- Built-in active PFC function
- Operating temperature range: -30°C to +70°C
- Protections: Short circuit, Overload, Over voltage, Over temperature
- DC OK active signal and redundant function (optional)
- Operating altitude up to 5000 meters (Note 5)
- LED indicator for power on
- 3 years warranty
Product Description
The UHP-200 series is a 200W single-output slim type power supply featuring a 26mm low profile design. It accepts a full range 90~264VAC input and offers output voltages from 3.3V to 55V. With high efficiency up to 94%, it operates from -30°C to +70°C under air convection without a fan. The UHP-200 series provides comprehensive protection functions and 5G anti-vibration capability. It complies with international safety regulations including TUV BS EN/EN62368-1, BS EN/EN60335-1, UL 62368-1, and GB 4943.1, making it a high-performance power supply solution for various industrial applications.
Applications
- Industrial automation machinery
- Industrial control systems
- Mechanical and electrical equipment
- Electronic instruments, equipment, or apparatus
- Household appliances
- LED display applications
- Power Source Equipment for PoE (55V model)
Specifications
Model Encoding
The model is encoded as UHP - 200 - [Output Voltage]. For example, UHP-200-24 for a 24V output.
GTIN CODE: MW Search: https://www.meanwell.com/serviceGTIN.aspx
General Specifications
Model | DC Voltage | Rated Current | Rated Power | Ripple & Noise (max.) Note.2 | Voltage Adj. Range | Voltage Tolerance Note.3 | Line Regulation | Load Regulation | Setup, Rise Time | Hold Up Time (Typ.) | Voltage Range Note.4 | Frequency Range | Power Factor (Typ.) | Efficiency (Typ.) | AC Current (Typ.) | Inrush Current (Typ.)Note.8 | Leakage Current |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
UHP-200-3.3 | 3.3V | 40A | 132W | 150mVp-p | 3.2~3.5V | ±2.0% | ±0.5% | ±1.0% | 2000ms, 80ms/230VAC; 3000ms, 80ms/115VAC at full load; 550ms/230VAC for 55V setup time | 10ms/230VAC | 90~264VAC | 47~63Hz | PF>0.94/230VAC | 89% | 2.2A/115VAC | Cold start 40A/115VAC | <0.75mA/240VAC |
UHP-200-4.2 | 4.2V | 40A | 168W | 150mVp-p | 3.6~4.4V | ±2.0% | ±0.5% | ±1.0% | (See above) | 10ms/115VAC | (See above) | (See above) | PF>0.98/115VAC at full load | 90% | 1.1A/230VAC | 80A/230VAC | (See above) |
UHP-200-5 | 5V | 40A | 200W | 200mVp-p | 4.5~5.5V | ±2.0% | ±0.5% | ±1.0% | (See above) | (See above) | (See above) | (See above) | (See above) | 91% | (See above) | (See above) | (See above) |
UHP-200-12 | 12V | 16.7A | 200.4W | 240mVp-p | 11.4~12.6V | ±1.0% | ±0.3% | ±0.5% | (See above) | (See above) | (See above) | (See above) | (See above) | 93% | (See above) | (See above) | (See above) |
UHP-200-15 | 15V | 13.4A | 201W | 240mVp-p | 14.3~15.8V | ±1.0% | ±0.3% | ±0.5% | (See above) | (See above) | (See above) | (See above) | (See above) | 94% | (See above) | (See above) | (See above) |
UHP-200-24 | 24V | 8.4A | 201.6W | 240mVp-p | 22.8~25.2V | ±1.0% | ±0.3% | ±0.5% | (See above) | (See above) | (See above) | (See above) | (See above) | 94% | (See above) | (See above) | (See above) |
UHP-200-36 | 36V | 5.6A | 201.6W | 240mVp-p | 34.2~37.8V | ±1.0% | ±0.3% | ±0.5% | (See above) | (See above) | (See above) | (See above) | (See above) | 94% | (See above) | (See above) | (See above) |
UHP-200-48 | 48V | 4.2A | 201.6W | 300mVp-p | 45.6~50.4V | ±1.0% | ±0.3% | ±0.5% | (See above) | (See above) | (See above) | (See above) | (See above) | 94% | (See above) | (See above) | (See above) |
UHP-200-55 | 55V | 3.6A | 201.6W | 360mVp-p | 45~58V | ±1.0% | ±0.3% | ±0.5% | (See above) | (See above) | (See above) | (See above) | (See above) | 94% | (See above) | (See above) | (See above) |
Protection Specifications
Protection | Type | Details |
---|---|---|
Overload | Hiccup mode | Recovers automatically after fault condition is removed |
Over Voltage | Shut down O/P voltage | Re-power on to recover |
Over Temperature | Shut down O/P voltage or Hiccup mode | Recovers automatically after temperature goes down |
Function Specifications
Function | Details |
---|---|
DC OK Signal (Optional) | Contact rating (max.): 15Vdc/10mA resistive load. Indicates output status. |
Redundant Function (Optional) | For parallel applications, enables automatic switchover if one PSU fails, ensuring system reliability. |
Environmental Specifications
Environment | Parameter | Value |
---|---|---|
Working Temp. | Temperature | -30 ~ +70°C (Refer to "Derating Curve") |
Humidity | 20 ~ 95% RH non-condensing | |
Storage Temp., Humidity | Temperature | -40 ~ +85°C |
Humidity | 10 ~ 95% RH non-condensing | |
Temp. Coefficient | (0~50°C) | ±0.03%/°C |
Vibration | 10~500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
Safety & EMC Specifications
Category | Standard/Compliance |
---|---|
Safety Standards | UL 62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1 (Except for 55V), GB 4943.1, EAC TP TC 004, KC62368-1 (only for UHP-200-24), BIS IS13252 (Part1): 2010/IEC 60950-1: 2005 (NOTE 10), BS EN/EN61558-1, BS EN/EN61558-2-16, BSMI CNS15598-1 approved |
Withstand Voltage | I/P-O/P: 3.75KVAC; I/P-FG: 2KVAC; O/P-FG: 1.25KVAC |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25°C/70%RH |
EMC Emission | Compliance to BS EN/EN55032, GB17625.1, GB/T 9254.1, Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, EAC TP TC 020, BSMI CNS15936 |
EMC Immunity | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN55035, heavy industry level, EAC TP TC 020 |
Other Specifications
Item | Value |
---|---|
MTBF | 2472.1 K hrs min. (Telcordia SR-332); 257.0K hrs min. (MIL-HDBK-217F) |
Dimension | 194*55*26mm (L*W*H) |
Packing | 0.468kg; 24pcs/12.2kg/0.49CUFT |
Notes:
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor.
- 3. Tolerance: includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. The ambient temperature derating of 5°C/1000m is needed for operating altitude greater than 2000m (6500ft).
- 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf).
- 7. R type efficiency slightly less than the Blank type, according to the actual measurement.
- 8. Inrush current parameter has 10% tolerance.
- 9. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
- 10. Some models or factory may not have the BIS marking, please contact MEAN WELL's sales for more details.
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
The block diagram illustrates the internal signal flow of the UHP-200 series power supply. Input power (I/P) first passes through an EMI Filter & Rectifier, followed by a PFC Circuit. This is then fed into the Power Switching stage, which is regulated by a Control circuit. The output is processed by Rectifiers & Filter to produce the final DC output (+V, -V). The diagram also shows a Detection Circuit monitoring Over Temperature Protection (O.T.P.), Over Load Protection (O.L.P.), and Over Voltage Protection (O.V.P.). Optional DC OK Function and Redundant Function are indicated. The switching frequencies are noted as PFC fosc: 100KHz and PWM fosc: 90KHz~110KHz.
Derating Curves
Derating curves illustrate the relationship between rated current percentage and ambient temperature for optimal performance. Three primary curves are presented:
- Ambient Temperature (°C) vs. Rated Current (%): Shows derating for "for other" models and "for 55V" models under general conditions.
- Ambient Temperature Without Aluminum Plate (°C) vs. Rated Current (%): Details derating for various input voltages (100Vac, 230Vac) and model types ("for 55V", "for other"), indicating reduced performance at higher temperatures without proper heat sinking.
- Tcase (°C) vs. Rated Current (%): Depicts the derating based on the case temperature, showing limits for "for 55V" and "for other" models, with a maximum operating range extending to 90°C.
Note 5 specifies that ambient temperature derating of 5°C/1000m is needed for operating altitudes greater than 2000m (6500ft).
Static Characteristic
The static characteristic graph shows the relationship between Input Voltage (V) at 60Hz and the Load (%). It indicates that the power supply operates efficiently across a wide input voltage range from 90VAC to 264VAC, maintaining full load capacity (100%) within this range.
Function Manual
1. DC OK Signal
The DC OK signal is an optocoupler output that indicates the power supply's output status. When the optocoupler's C-E pins conduct, the PSU is turned on and the DC OK signal is active (DC ok). When the optocoupler's C-E pins are open, the PSU is turned off, and the DC OK signal indicates a DC fail. The optocoupler has a maximum rating of 15Vdc/10mA resistive load.
2. Redundant Function
The UHP-200R models feature a built-in redundant function, allowing two units to be connected in parallel for increased reliability. In parallel operation, the total load should not exceed the rated power of a single PSU.
Mechanical Specification
The UHP-200 series has a slim profile with dimensions of 194mm (Length) x 55mm (Width) x 26mm (Height). The unit case number is 249B, with a tolerance of ±1mm.
Terminal Assignments
AC Input Terminal (TB1)
- Pin 1: AC/L
- Pin 2: AC/N
- Terminal: (DEGSON) DG28C-B-03P
- Max mounting torque: 5Kgf-cm
DC Output Terminal (TB2, TB3)
- Pins 1, 2: -V
- Pins 3, 4: +V
- Terminal: (MW) TB-HTP-200-40A
- Max mounting torque: 8Kgf-cm
DC OK Connector (CN10)
- Pin 1: DC COM
- Pin 2: DC OK +V
- Mating Housing: JST PHR-2 or equivalent
- Terminal: JST SPH-002T-P0.5S or equivalent
Note: tc indicates Max. Case Temperature.
Installation
1. Operation with Additional Aluminum Plate
To meet the derating curves and static characteristics, the UHP-200 series must be installed onto an aluminum plate or a cabinet of equivalent size on the bottom. The suggested aluminum plate size is 300mm x 300mm. For optimal thermal performance, the aluminum plate should have an even and smooth surface, potentially coated with thermal grease. The UHP-200 series must be firmly mounted at the center of this plate. Mounting is done using M3 screws (4 required).
Related Documents
![]() |
MEAN WELL UHP-200A Series: 200W Single Output PFC Power Supply Explore the MEAN WELL UHP-200A series, a 200W single output AC-DC power supply with active PFC. This fanless, ultra-low profile unit is ideal for LED signage, moving signs, LED channel letters, and LED TV walls, offering high efficiency and reliability. |
![]() |
MEAN WELL UHP-350 Series 350W Slim Type Switching Power Supply Datasheet Technical datasheet for the MEAN WELL UHP-350 series, a 350W slim type, single-output switching power supply with PFC. Features include wide input range, high efficiency, -30~+70°C operation, and comprehensive protection functions. Suitable for industrial automation, control systems, and more. |
![]() |
MEAN WELL LRS-200 Series 200W Single Output Power Supply Datasheet Comprehensive datasheet for the MEAN WELL LRS-200 Series 200W single output enclosed power supply, detailing features, applications, electrical specifications, dimensions, and safety compliance. |
![]() |
MEAN WELL LRS-200 Series 200W Single Output Switching Power Supply Specifications Comprehensive technical specifications for the MEAN WELL LRS-200 series 200W single output switching power supplies. Details include electrical characteristics, features, applications, environmental specifications, safety compliance, and mechanical dimensions for models ranging from 3.3V to 48V. |
![]() |
MEAN WELL LRS-200 Series 200W Single Output Switching Power Supply Datasheet Comprehensive technical datasheet for the MEAN WELL LRS-200 series of 200W single-output enclosed switching power supplies. This document details features, applications, electrical specifications, environmental conditions, safety compliance, block diagrams, derating curves, static characteristics, and mechanical dimensions for models LRS-200-3.3 through LRS-200-48. |
![]() |
MEAN WELL MSP-200 Series 200W Single Output Medical Type Power Supply Specifications Detailed specifications, features, and technical data for the MEAN WELL MSP-200 series 200W single output medical type power supply, including electrical characteristics, environmental specifications, and safety approvals. |
![]() |
MEAN WELL LRS-200 Series 200W Single Output Switching Power Supply Detailed specifications and features for the MEAN WELL LRS-200 series, a 200W single-output enclosed switching power supply. Covers applications in industrial automation, control systems, and electronic equipment, with features like wide input range, high efficiency, low no-load power consumption, and robust protection. |
![]() |
MEAN WELL LRS-200 Series 200W Single Output Switching Power Supply Specifications Detailed specifications for the MEAN WELL LRS-200 series of 200W single-output enclosed switching power supplies. Features include wide AC input range, high efficiency, low no-load power consumption, and compliance with international safety standards. Ideal for industrial automation, control systems, and electronic equipment. |