Indoor Unit Features
- Unique blow-through design for simple coil cleaning when the blower is removed.
- Selectable external static pressure (0.30, 0.50, 0.80 in.WG) with 3 fan speeds.
- Positive pressure cabinet with air leakage less than 1.0% at 1.0 in.WG.
- Optional humidifier control and ERV control.
- Optional electric heat kit for additional heat capacity.
- Multiple control options: comfort app, third-party interfaces, wired and wireless controllers.
- Multi-zone capability for temperature management of multiple zones.
- Multi-position installation: horizontal (left/right), vertical (up/down).
- Fiberglass-free insulation (1 inch R4.2) reduces condensation and boosts efficiency.
- Enclosed ECM motor for high efficiency.
- Ducted air handler design for cooling and heating large zones.
Outdoor Unit Features
- Blue Fin Coating: Anti-corrosion treatment on heat exchanger fins protects against salt, sulfur, and airborne contaminants.
- High-performance grooved piping for increased heat exchange efficiency.
- Hot-Start Technology: Fan activates only when the heat exchanger is warm to prevent cold air blasts.
- INVERTER-driven compressor for precise capacity control and stable temperature.
- Joint Lap DC Motor for high efficiency and reliability.
- Pulse Amplitude Modulation technology enhances energy efficiency and optimizes compressor performance.
- Quiet operation: Units are as quiet as a typical conversation.
- Single-zone capability: Connects one outdoor unit to one indoor unit for single-space comfort.
Specifications
Cooling & Heating Specifications
Parameter | Unit | Cooling at 95°F | Heating at 47°F | Heating at 17°F | Heating at 5°F | Heating at -4°F |
---|---|---|---|---|---|---|
Maximum Capacity | Btu/h | 60,000 | 67,000 | 42,500 | 34,600 | 31,000 |
Rated Capacity | Btu/h | 60,000 | 66,500 | 42,500 | 34,600 | 31,000 |
Minimum Capacity | Btu/h | 18,500 | 14,600 | |||
Maximum Power Input | W | 6,070 | 6,740 | 5,415 | 5,070 | |
Rated Power Input | W | 5,490 | 6,720 | 5,415 | 5,070 | |
Moisture Removal | Pints/h | 14.3 | ||||
Sensible Heat Factor | - | 0.74 | ||||
Power Factor [208V/230V] | % | 99/99 | 97/97 |
Efficiency Specifications
Parameter | Unit | Value |
---|---|---|
SEER2 | 17 | |
EER21 | 9 | |
HSPF2 [IV] | 8 | |
COP at 47°F | 2.9 | |
COP at 17°F at Maximum Capacity | 2.3 | |
COP at 5°F at Maximum Capacity | 2 | |
COP at -4°F at Maximum Capacity | 1.88 | |
ENERGY STAR® Certified | No |
Electrical Specifications
Parameter | Unit | Value |
---|---|---|
Voltage, Phase, Frequency | VAC/VAC, Ø, Hz | 208 / 230, 1, 60 |
Guaranteed Voltage Range | VAC | 198 - 253 |
Voltage: Indoor - Outdoor, S1-S2 | VAC | IDU Powered Separately |
Voltage: Indoor - Outdoor, S2-S3 | V DC | 12-24 |
Short-circuit Current Rating [SCCR] | kA | 5 |
Recommended Fuse/Breaker Size (Outdoor) | A | 40 |
Recommended Wire Size [Indoor - Outdoor] | AWG | 14 |
MCA | A | 9.3 |
Indoor Unit Specifications
Parameter | Unit | Value |
---|---|---|
Fan Motor Output | W | 750 |
Airflow Rate at Cooling, Dry | CFM | 1,155, 1,400, 1,650 |
Airflow Rate at Cooling, Wet | CFM | 1,155, 1,400, 1,650 |
Airflow Rate at Heating, Dry | CFM | 1,225, 1,485, 1,750 |
Sound Pressure Level [Cooling] | dB (A) | 48, 55, 56 |
Sound Pressure Level [Heating] | dB (A) | 48, 55, 56 |
External Static Pressure | in.WG | 0.30, 0.50, 0.80 |
Drain Pipe Size O.D. | inch [mm] | 3/4 [19.05] |
External Finish Color | 6.2PB 9/0.9 | |
Unit Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 25 x 21-5/8 x 59-1/2 [635 x 548 x 1,511] |
Package Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 26 x 28-3/4 x 66 [660 x 730 x 1,675] |
Unit Weight | lbs [kg] | 176 [80] |
Package Weight | lbs [kg] | 200 [91] |
Fan Motor Type | DC Motor | |
IDU Operating Temp. Range | °FDB, °FWB / °FDB, °FWB °FDB | 90, 73 / 66, 59 82 / 50 |
Outdoor Unit Specifications
Parameter | Unit | Value |
---|---|---|
MCA | A | 38 |
MOCP | A | 67 |
Fan Motor Output | W | 213+213 |
Airflow Rate Cooling | CFM | 4,020 |
Airflow Rate Heating | CFM | 4,020 |
Defrost Method | Reverse Cycle | |
Coating on Heat Exchanger (Bluefin, Sea Coast) | Yes, Yes | |
Sound Pressure Level, Cooling¹ | dB (A) | 60 |
Sound Pressure Level, Heating² | dB (A) | 62 |
Compressor Type | Twin Rotary | |
Compressor Model | MRK53FFJMC-L | |
Compressor Oil [Type // Charge] | Type // oz | RM68EH // 60 |
External Finish Color | Munsell 3Y 7.8/1.1 | |
Base Pan Heater | Not applicable | |
Unit Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 41-11/32 x 14 x 52-43/64 [1,050 x 355 x 1,338] |
Package Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 42-15/16 x 17-3/4 x 58-5/16 [1,090 x 450 x 1,480] |
Unit Weight | lbs [kg] | 264.60 [120] |
Package Weight | lbs [kg] | 291 [132] |
Cooling Intake Air Temp [Maximum / Minimum*] | °FDB | 115 / 23 |
ODU Operating Temp. Range | °FDB, °FWB / °FDB, °FWB | 70, 59 / -4, -4 |
Heating Intake Air Temp [Maximum / Minimum] | °FDB | -13 / -4 |
Refrigerant Type | R454B | |
Pre-Charged Refrigerant Amount | lbs, oz | 11, 7 |
Maximum Pre-Charged Piping Length | ft [m] | 100 [30] |
Additional Refrigerant Charge Per Additional Piping Length | oz/ft | 0.6 |
Gas Pipe Size O.D. [Flared] | inch [mm] | 3/4 [19.05] |
Liquid Pipe Size O.D. [Flared] | inch [mm] | 3/8 [9.52] |
Maximum Piping Length | ft [m] | 245 [75] |
Maximum Height Difference | ft [m] | 100 [30] |
Maximum Number of Bends | 15 |
Accessories
Indoor Unit Accessories (SVZ-AP60NL)
- Wireless Remote Controller: Lockdown Bracket, RedLINK Wireless Remote Controller, Universal Wireless MA Handheld Remote Controller, Universal Wireless Receiver
- Power Supplies & Auxiliary Components: 3-Pin Wiring Harness, 5-Pin Wiring Harness, ERV On/Off Input Adapter
- Electric Kit Heats: 10kW, 15kW, 17kW, 19kW Electric Heaters
- Control Interface: Airzone Wired Blueface Controllers (Black/White), Airzone Wired Lite Controllers (White), Airzone Wireless Lite Controller (White), Airzone Wireless Think Controllers (Black/White), IT Extender for kumo station, kumo station, Operation and Error Status Output Adapter, Procon BACnet and Modbus Interface, Thermostat Interface, Wireless Interface Adapter
- Remote Sensor: Flush Mount Remote Temperature Sensor, Wall Mount Remote Temperature Sensor, Wireless temperature and humidity sensor
- Condensate: Blue Diamond Advanced Mini Condensate Pump, Blue Diamond MegaBlue Advanced Condensate Pump, Blue Diamond Sensor Extension Cable, Refco Condensate Pump, Sauermann Condensate Pump
- Wired Remote Controller: Deluxe Wired MA Remote Controller, Simple Direct Wired Remote Controller, Simple MA Remote Controller, Touch MA Wired Remote Controller
- Disconnect Switch: 30A600VUL fits 2 X 4 utility box (Black/White)
- Power Supplies and Auxiliary Components: Backup Heat Relay Kit Adapter
- Control Wire: 202PR 1PR shielded 1PR plenum wire (100 ft, 500 ft reels)
- Downflow Kit: Condensate Management Kit for downflow installation
- Lineset: 15 x 3/8 x 15 x 3/4 Lineset Twin-Tube Insulation, 50 x 3/8 x 50 x 3/4 Lineset Twin-Tube Insulation
- Electric Heat Lockout: Electric Heat Lockout
- Terminal Block: Separate Terminal Power Block
Outdoor Unit Accessories (SUZ-AK60NL)
- Control/Service Tool: ControlService Tool, M- & P-Series Maintenance Tool Cable Set, Maintenance Tool Interface
- Stand: 18 Dual Fan Stand, 24 Dual Fan Stand
- Optional Defrost Heater: Optional Defrost Heater
- Snow/Rain Diverter: Snow/Rain Diverter
- Wind Baffle: Front Wind Baffle, Rear Wind Baffle, Side Advanced Wind Baffle
- Mounting Pad: Condensing Unit Mounting Pad 24 x 42 x 3
- Hail Guards: Hail Guard
- Mini-Split Wire: 14 Gauge 4 wire Armored MiniSplit Cable (250 ft, 50 ft rolls)
- Centralized Drain Pan: Centralized Drain Pan
- Power Supplies & Auxiliary Components: 3-Pin Wiring Harness, 5-Pin Wiring Harness
- Drain Socket: Drain Socket
- Air Outlet Guide: Air Outlet Guide 1 Piece
- M-NET Converter: M-Net Interface for P-Series
Dimensions
Detailed diagrams illustrate the physical dimensions and connection points for both the indoor (SVZ-AP60NL) and outdoor (SUZ-AK60NL) units. These diagrams provide measurements for width, depth, height, and the location of piping, wiring, and drain connections.
Indoor Unit (SVZ-AP60NL) Key Dimensions:
- Nominal Filter Size: 508 x 609.6 x 25.4 mm (20 x 24 x 1 inches)
- Duct Connection: 579 x 402 mm (22-13/16 x 15-7/8 inches)
- Overall Dimensions (W x D x H): 635 x 579 x 1511 mm (25 x 22-13/16 x 59-1/2 inches)
- Gas Pipe Size: 15.88 mm (5/8 inch)
- Liquid Pipe Size: 9.52 mm (3/8 inch)
Outdoor Unit (SUZ-AK60NL) Key Dimensions:
- Overall Dimensions (W x D x H): 1,050 x 355 x 1,338 mm (41-11/32 x 14 x 52-43/64 inches)
- Service Space Requirements: Minimum 1000mm (39-3/8 inches) clearance for service access.
- Foundation Bolt Size: M10 (3/8 inch)
- Piping/Wiring Connections: Available from Front, Right, Rear, and Below directions.
Specifications are subject to change without notice.
© 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Contact: 1340 Satellite Boulevard Suwanee, GA 30024 | Toll Free: 800-433-4822 | Website: https://mitsubishicomfort.com