DocumentDocumentJob Name: System Reference: PEAD-A30AA9 & SUZ-KA30NA2 MID STATIC HORIZONTAL-DUCTED INDOOR UNIT 30,000 BTU/H HEAT PUMP UNIVERSAL OUTDOOR UNIT Indoor Unit Outdoor Unit Date: PEAD-A30AA9 SUZ-KA30NA2 INDOOR UNIT FEATURES · Unobtrusive ceiling-concealed design for short-run ductwork · Wide ranging external static pressure (0.14-0.60 in. WG) · Built-in condensate lift mechanism (up to 27-9/16") · Auto fan speed mode · Optional FB Series filter boxes for easy access and service · Ideal for residential homes, retail shopping centers, larger classrooms, office complexes, conference rooms, ballrooms, fitness centers, and more · Multiple control options available: kumo cloud® smart device app for remote access Third-party interface options Wired or wireless controllers OUTDOOR UNIT FEATURES · Variable speed INVERTER-driven compressor · Innovative Joint Lap DC Motor leads to high efficiency and reliability · Pulse Amplitude Modulation technology · High-performance grooved piping for increased heat exchange efficiency Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: PEAD-A30AA9 & SUZ-KA30NA2 test Cooling at 95°F1 Heating at 47°F2 Heating at 17°F3 Efficiency Electrical Indoor Unit Indoor Unit Operating Temperature Range Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Moisture Removal Sensible Heat Factor Power Factor [208V / 230V] Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Power Factor [208V / 230V] Maximum Capacity Rated Capacity Maximum Power Input Rated Power Input SEER2 EER21 HSPF2 [IV] COP at 47°F2 COP at 17°F at Maximum Capacity3 ENERGY STAR® Certified Voltage, Phase, Frequency Guaranteed Voltage Range Voltage: Indoor - Outdoor, S1-S2 Voltage: Indoor - Outdoor, S2-S3 Short-circuit Current Rating [SCCR] Recommended Fuse/Breaker Size (Outdoor) Recommended Wire Size [Indoor - Outdoor] Power Supply MCA Fan Motor Full Load Amperage Fan Motor Output Fan Motor Type Airflow Rate at Cooling, Dry Airflow Rate at Heating, Dry Sound Pressure Level [Cooling] Sound Pressure Level [Heating] External Static Pressure Drain Pipe Size Condensate Lift Mechanism, Maximum Distance Coating on Heat Exchanger External Finish Color Unit Dimensions Package Dimensions Unit Weight Package Weight Cooling Intake Air Temp [Maximum / Minimum]* Heating Intake Air Temp [Maximum / Minimum] BTU/H BTU/H BTU/H W W Pints/h % BTU/H BTU/H BTU/H W W % BTU/H BTU/H W W V AC V AC V DC kA A AWG A A W CFM CFM dB[A] dB[A] in.WG In. [mm] In. [mm] W x D x H: In. [mm] W x D x H: In. [mm] Lbs. [kg] Lbs. [kg] °F °F 27,000 27,000 12,800 2,240 2,240 3.9 0.84 98.0 / 98.0 33,000 30,000 15,800 2,810 2,460 98.0 / 98.0 26,500 24,800 2,250 1,960 19.4 12.0 11.7 3.5 3.4 Yes 208/230, 1, 60 187 - 253 208/230 24 5 20 14 Indoor unit is powered by the outdoor unit 2.25 1.80 121 DC Motor 618671742883 618671742883 30323438 30323438 0.140.20.280.40.6 1-1/4 [32] 27-9/16 [700] -- Galvanized 43-5/16 x 28-7/8 x 9-7/8 [1,100 x 732 x 250] 53-15/16 x 35-7/16 x 13 [1,370 x 900 x 330] 67 [30] 78 [35] 95 DB, 71 WB / 67 DB, 57 WB 80 DB / 70 DB NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): · Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): · System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: PEAD-A30AA9 & SUZ-KA30NA2 test Outdoor Unit Outdoor Unit Operating Temperature Range Refrigerant Piping MCA MOCP Fan Motor Full Load Amperage Fan Motor Output Airflow Rate [Cooling / Heating] Refrigerant Control Defrost Method Coating on Heat Exchanger Sound Pressure Level, Cooling1 Sound Pressure Level, Heating2 Compressor Type Compressor Model Compressor Rated Load Amps Compressor Locked Rotor Amps Compressor Oil [Type // Charge] External Finish Color Base Pan Heater Unit Dimensions Package Dimensions Unit Weight Package Weight Cooling Air Temp [Maximum / Minimum]* Cooling Thermal Lock-out / Re-start Temperatures** Heating Air Temp [Maximum / Minimum] Heating Thermal Lock-out / Re-start Temperatures** Type Pre-Charged Refrigerant Amount Maximum Pre-Charged Piping Length Additional Refrigerant Charge Per Additional Piping Length Gas Pipe Size O.D. [Flared] Liquid Pipe Size O.D. [Flared] Maximum Piping Length Maximum Number of Bends A A A W CFM dB(A) dB(A) A A oz. W x D x H: In. [mm] W x D x H: In. [mm] Lbs. [kg] Lbs. [kg] °F °F °F °F Lbs, oz Ft. [m] oz./Ft. [g/m] In.[mm] In.[mm] Ft. [m] 17.0 31 1.0 60 2020 / 1930 Linear expansive valve Reverse Cycle Blue Fin Coating 55 55 DC INVERTER-driven Twin Rotary SNB220FQGM1T 13 16.0 FV50S Ivory Munsell 3Y 7.8/1.1 Optional 33-1/16 x 13 x 34-5/8 [840 x 330 x 880] 38-3/4 x 16-3/4 x 39 [980 x 420 x 990] 129 [58.5] 148 [67] 115 DB / 14 DB 1 / 5 75 DB, 65 WB / 14 DB, 12 WB 4 / 14 R410A 4.0, 14.0 25.0 [7.5] 2.69 [50] 5/8 [15.88] 3/8 [9.52] 100 [30] 10 NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): · Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): · System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. INDOOR UNIT ACCESSORIES: PEAD-A30AA9 Control Interface Remote Sensor Wired Remote Controller Wireless Remote Controller Condensate Control Wire Disconnect Switch Filter Box Lineset 3-Pin Connector Airzone Wired Blueface Principal Controller White Airzone Wired Lite Controller White Airzone Wireless Lite Controller White Airzone Wireless Think Controller White Airzone ZBS Wired Blueface Principal Controller White CN24 Relay Kit IT Extender kumo station® for kumo cloud® Procon BACnet® and Modbus® Interface Remote Operation Adapter Thermostat Interface USNAP Adapter Wireless Interface for kumo cloud® Flush Mount Remote Temperature Sensor Remote Temperature Sensor Wireless temperature and humidity sensor for kumo cloud® Deluxe Wired MA Remote Controller Simple Ductless Wired Remote Controller Simple MA Remote Controller Touch MA Controller kumo touchTM RedLINKTM Wireless Controller Lockdown bracket for remote controller Wireless MA Receiver Wireless MA Remote Controller Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor Blue Diamond Sensor Extension Cable -- 15 Ft. Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H 20/2PR, 1PR shielded + 1PR plenum wire for Airzone, 100 ft reel 20/2PR, shielded + 1PR plenum wire for Airzone, 500 ft reel (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White Filter Box with MERV 13 Filter 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation) NOTES: PAC-SF40RM-E (Unable to use with wireless remote controller) PAC-715AD AZZBSBLUEZEROCB AZZBSLITECB AZZBSLITERB AZZBSTHINKRB AZZBSBLUEFACECB CN24RELAY-KIT-CM3 PAC-WHS01IE-E PAC-WHS01HC-E PAC-UKPRC001-CN-1 PAC-SF40RM-E PAC-US445CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 PAC-USSEN002-FM-1 PAC-SE41TS-E PAC-USWHS003-TH-1 PAR-40MAAU PAC-SDW01RC-1 PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2 RCMKP1CB PAR-FA32MA-W PAR-FL32MA-E X87-721 X87-835 C13-103 COMBI CW2042S2-100 CW2042S2-500 TAZ-MS303 TAZ-MS303W FBM2-3-A MPLS385812T-10 MPLS385812T-100 MPLS385812T-15 MPLS385812T-30 MPLS385812T-50 MPLS385812T-65 Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Control/Service Tool Drain Socket Mini-Split Wire Mounting Pad Optional Defrost Heater Snow/Rain Diverter Stand OUTDOOR UNIT ACCESSORIES: SUZ-KA30NA2 Air Outlet Guide M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection) Drain Socket 14 Gauge, 4 wire MiniSplit Cable--250 ft. roll 14 Gauge, 4 wire MiniSplit Cable--250 ft. roll 14 Gauge, 4 wire MiniSplit Cable--50 ft. roll 14 Gauge, 4 wire MiniSplit Cable--50 ft. roll 16 Gauge, 4 wire MiniSplit Cable--250 ft. roll 16 Gauge, 4 wire MiniSplit Cable--250 ft. roll 16 Gauge, 4 wire MiniSplit Cable--50 ft. roll 16 Gauge, 4 wire MiniSplit Cable--50 ft. roll Condensing Unit Mounting Pad: 16" x 36" x 3" Base Heater Snow/Rain Diverter 18" Single Fan Stand 24" Single Fan Stand Condenser Wall Bracket Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Outdoor Unit Stand -- 12" High MAC-886SG-E M21EC0397 M21EC1397 MAC-871DS S144-250 SW144-250 S144-50 SW144-50 S164-250 SW164-250 S164-50 SW164-50 ULTRILITE1 MAC-642BH-U1 SRD-3 QSMS1801M QSMS2401M QSWB2000M-1 DSD-400P QSMS1201M Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 40(1-5/8) 200(7-7/8) A B (Suspension bolt pitch) C G D (Duct) 100(3-15/16)×(E-1)=F 100(3-15/16) INDOOR UNIT DIMENSIONS: PEAD-A30AA9 INDOOR UNIT PEAD-A09, 12, 15, 18, 24, 30, 36, 42AA9 Specifications are subject to change without notice. Opposite piping side view Outlet air side view 15(5/8) Bottom Top 2×E-ø2.9(1/8) Top view 378(14-15/16) Drain pipe (O.D ø32(1-1/4) (Emergency drain) 120° (4ø-11255/16) 120° 135 (5-3/8) 153(6-1/16) Fresh air intake ø100(3-15/16) knock out hole Note 5 3-ø2.9(1/8) mount hole 18(3/4) Inlet air side view 210(8-5/16) Notes 1.Use an M10 screw for the suspension bolt (field supply). 2.Keep the service space for maintenance at the bottom. 3.This drawing is for PEAD-A09·12·15·18·24· 30AA9 models,which have 2 fans. PEAD-A36·42AA9 models have 3 fans. 4.If the inlet duct is used,remove the air filter(supplied with the unit),then install the filter(field supply) at the suction side. 5.Heat air to 0°C(32°F) or higher when taking fresh air with a fresh air intake. 58(2-5/16) J±3(J±1/8) H±3(H±1/8) 40(1-5/8) 23(15/16) 40(1-5/8) 122(4-13/16) 178(7-1/16) (DUCT) 100(3-15/16) 33(1-5/16) © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Air outlet inlet 10(7/16) 21(7/8) 23(15/16) 20(13/16) 30(1-3/16) 57(2-1/4) 32(1-5/16) 2×2-ø2.9(1/8) 2 Refrigerant piping(liquid) 1 Refrigerant piping (gas) (Suspension bolt pitch) 643(25-3/8) 732(28-7/8) 700(27-9/16) 238(9-3/8) Drain pipe Drain pump 10(7/16) (Integral lift pump outlet) (O.D ø32(1-1/4) Top 41(1-5/8) 217(8-9/16) 250(9-7/8) Piping side view (5-3/8) (2-11/16) 136 67 356(14-1/16) Control box Bottom Terminal block(Transmission) Terminal block(Power source) Drain pipe(O.Dø32(1-1/4))(Gravity drain) Air filter Model PEAD-A09AA9 PEAD-A12,15, 18AA9 PEAD-A24,30AA9 PEAD-A36,42AA9 J 62 (2-1/2) 66 (2-5/8) Unit:mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52 (3/8) ø6.35 ø12.7 (1/4) (1/2) ø15.88 (5/8) ø9.52 (3/8) Unit:mm(in.) Model A B C DEF G H PEAD-A09,12, 900 954 1000 15,18AA9 (35-7/16) (37-9/16) (39-3/8) 860 (33-7/8) 9 800 858 72 (31-1/2) (33-13/16) (2-7/8) PEAD-A24,30AA9 1100 1154 (43-5/16) (45-7/16) 1200 (47-1/4) 1060 (41-3/4) 11 1000 1058 (39-3/8) (41-11/16) 78 PEAD-A36,42AA9 1400 (55-1/8) 1454 (57-1/4) 1500 1360 (59-1/16) (53-9/16) 14 1300 (51-3/16) 1358 (53-1/2) (3-1/8) 13 2 14-3/16 Clear *1 OUTDOOR UNIT DIMENSIONS: SUZ-KA30NA2 16-7/16 Air in Air in REQUIRED SPACE *1 20 in. (500 mm) or more when front and sides of the unit are clear Drain hole 1-5/8 1-9/16 4 or mino. r(e100 mm) Unit: inch 4 oinr.m(1o0r0e mm) 6-7/8 Air out 19-11/16 33-1/16 4-5/16 2-holes 13/32 13/16 3-3/16 20orinm. (o5r0e0*2mm) o1r 4mionr.e(350 mm) *2 When any 2 sides of left, right and rear of the unit are clear Service panel Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 (KA18) Refrigerant pipe (flared) Ø 3/8 (KA24/30/36) 35 44 6-1/2 3-29/32 7-11/16 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 1/2 (KA18) Refrigerant pipe (flared) Ø 5/8 (KA24/30/36) 34-5/8 17-25/32 FORM# PEAD-A30AA9 & SUZ-KA30NA2 - 202404 Specifications are subject to change without notice. 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.