Mitsubishi Electric MSZ-EX09NLW & SUZ-AA09NLHZ Hyper Heat Pump System
Job Name:
System Reference:
Date:
Indoor Unit Features (MSZ-EX09NLW)
- Dual Barrier Coating: Patented coating reduces contaminant buildup on the heat exchanger for optimal airflow and easier maintenance.
- Econo Cool: Automatically adjusts airflow based on heat exchanger temperature, slightly increasing the set temperature to save energy while maintaining comfort.
- Modern Design: Sleek and modern aesthetic.
- Multiple Control Options: Includes a back-lit screen hand-held remote controller, comfort app, third-party interfaces, and wired/wireless controllers.
Outdoor Unit Features (SUZ-AA09NLHZ)
- Blue Fin Coating: Anti-corrosion treatment on aluminum fins of the heat exchanger protects against airborne contaminants, especially in coastal and industrial areas.
- Built-in Base Pan Heater: Prevents ice buildup in the base pan.
- Hot-Start Technology: Ensures the fan only activates when the heat exchanger is warm, preventing cold air blasts during start-up.
- Hyper-Heating INVERTER® (H2i®): Provides 100% heating capacity down to 5°F and guaranteed heating down to -13°F.
- Joint Lap DC Motor: High efficiency and reliability.
- Outdoor Unit Directed Power: The outdoor unit powers the indoor unit; the system automatically restarts after a power outage.
- Pulse Amplitude Modulation Technology: Enhances energy efficiency by optimizing compressor power supply for precise capacity control and reduced energy consumption.
- Quiet Operation: Units operate quietly, comparable to a typical conversation.
Specifications
Cooling Performance
Parameter | Unit | Value |
---|---|---|
Maximum Capacity | Btu/h | 9,000 |
Rated Capacity | Btu/h | 9,000 |
Minimum Capacity | Btu/h | 4,800 |
Maximum Power Input | W | 710 |
Rated Power Input | W | 710 |
Moisture Removal | Pints/h | 0.3 |
Sensible Heat Factor | - | 0.96 |
Power Factor [208V/230V] | % | 91/91 |
Heating Performance
Parameter | Unit | Value |
---|---|---|
Heating at 47°F Max Capacity | Btu/h | 15,000 |
Heating at 47°F Rated Capacity | Btu/h | 12,000 |
Heating at 47°F Min Capacity | Btu/h | 8,300 |
Heating at 47°F Max Power Input | W | 1,160 |
Heating at 47°F Rated Power Input | W | 900 |
Heating at 47°F Power Factor [208V/230V] | % | 94/94 |
Heating at 17°F Max Capacity | Btu/h | 12,000 |
Heating at 17°F Rated Capacity | Btu/h | 7,300 |
Heating at 17°F Max Power Input | W | 1,250 |
Heating at 17°F Rated Power Input | W | 860 |
Heating at 5°F Max Capacity | Btu/h | 12,000 |
Heating at 5°F Max Power Input | W | 1,758 |
Heating at -13°F Max Capacity | Btu/h | 7,300 |
Efficiency
Parameter | Unit | Value |
---|---|---|
SEER2 | - | 17.4 |
EER2¹ | - | 12.6 |
HSPF2 [IV] | - | 10 |
COP at 47°F² | - | 3.9 |
COP at 17°F at Maximum Capacity³ | - | 2.8 |
COP at 5°F at Maximum Capacity⁴ | - | 2 |
ENERGY STAR® Certified | - | Yes |
Electrical
Parameter | Unit | Value |
---|---|---|
Voltage, Phase, Frequency | VAC/VAC,, Hz | 208/230, 1, 60 |
Guaranteed Voltage Range | VAC | 198-253 |
Voltage: Indoor - Outdoor, S1-S2 | VAC | 208/230 |
Voltage: Indoor - Outdoor, S2-S3 | V DC | 12-24 |
Short-circuit Current Rating [SCCR] | KA | 5 |
Recommended Fuse/Breaker Size (Outdoor) | A | 25 |
Recommended Wire Size [Indoor - Outdoor] | AWG | 14 |
Indoor Unit
Parameter | Unit | Value |
---|---|---|
Fan Motor Output | W | 30 |
Airflow Rate at Cooling, Dry | CFM | 143, 164, 228, 305, 391 |
Airflow Rate at Cooling, Wet | CFM | 128, 147, 205, 274, 352 |
Airflow Rate at Heating, Dry | CFM | 143, 164, 205, 244, 448 |
Sound Pressure Level [Cooling] | dB (A) | 21, 23, 29, 36, 42 |
Sound Pressure Level [Heating] | dB (A) | 21, 24, 29, 37, 45 |
Drain Pipe Size O.D. | inch [mm] | 5/8 [16] |
Dual Barrier Coating on Heat Exchanger | - | Yes |
External Finish Color | - | 0.7PB 9.2/0.4 |
Unit Dimensions (W x D x H) | inch [mm] | 34-13/16 x 7-11/16 x 11-3/4 [885 x 195 x 299] |
Package Dimensions (W x D x H) | inch [mm] | 35-5/8 x 14-3/16 x 10-11/16 [980 x 360 x 270] |
Unit Weight | lbs [kg] | 26 [11.50] |
Package Weight | lbs [kg] | 29 [13] |
Fan Motor Type | - | DC Motor |
Cooling Intake Air Temp [Maximum / Minimum] | °FDB, °FWB / °FDB, °FWB | 90, 73/67, 57 |
Heating Intake Air Temp [Maximum / Minimum] | °FDB | 80/70 |
Outdoor Unit
Parameter | Unit | Value |
---|---|---|
MCA | A | 24 |
MOCP | A | 41 |
Fan Motor Output | W | 50 |
Airflow Rate Cooling | CFM | 2,193 |
Airflow Rate Heating | CFM | 1,949 |
Defrost Method | - | Reverse Cycle |
Coating on Heat Exchanger (Bluefin, Sea Coast) | - | Yes, Yes |
Sound Pressure Level, Cooling¹ | dB (A) | 54 |
Sound Pressure Level, Heating² | dB (A) | 55 |
Compressor Type | - | Twin Rotary |
Compressor Model | - | SRB172FQHMT |
Compressor Oil [Type // Charge] | Type // oz | RM68EH // 14.54 |
External Finish Color | - | Munsell No.3Y 7.8/1.1 |
Base Pan Heater | - | Built-in |
Unit Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 33-1/16 x 13 x 34-5/8 [840 x 330 x 880] |
Package Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 38-5/8 x 16-9/16 x 39 [980 x 420 x 990] |
Unit Weight | lbs [kg] | 115 [52.16] |
Package Weight | lbs [kg] | 133 [60.33] |
Cooling Intake Maximum Air Temp [Maximum / Minimum*] | °FDB | 115/14 |
Cooling Thermal Lock-out / Re-start Temperatures** | °FDB, °FWB / °FDB, °FWB | -1/3 |
Heating Air Temp [Maximum / Minimum] | °FWB | 75, 65/-13, -14 |
Heating Thermal Lock-out / Re-start Temperatures** | °FDB | -22.5/-14 |
Refrigerant
Parameter | Unit | Value |
---|---|---|
Type | - | R454B |
Pre-Charged Refrigerant Amount | Ibs | 3 |
Maximum Pre-Charged Piping Length | ft [m] | 25 [7.60] |
Additional Refrigerant Charge Per Additional Piping Length | oz/ft | 0.22 |
Piping
Parameter | Unit | Value |
---|---|---|
Gas Pipe Size O.D. [Flared] | inch [mm] | 3/8 [9.52] |
Liquid Pipe Size O.D. [Flared] | inch [mm] | 1/4 [6.35] |
Maximum Piping Length | ft [m] | 100 [30] |
Maximum Height Difference | ft [m] | 50 [15] |
Maximum Number of Bends | - | 10 |
Indoor Unit Accessories
Control Interface
- Airzone Wired Blueface Controller Black (AZZBSBLUEZEROCN)
- Airzone Wired Blueface Controller White (AZZBSBLUEZEROCB)
- Airzone Wireless Lite Controller Black (AZZBSLITERN)
- Airzone Wireless Lite Controller White (AZZBSLITERB)
- Airzone Wireless Think Controller Black (AZZBSTHINKRN)
- Airzone Wireless Think Controller White (AZZBSTHINKRB)
- IT Extender for kumo station (PAC-WHS01IE-E)
- kumo station for the Comfort app (PAC-WHS01HC-E)
- M-Net I/O Control Interface for M-Series 2 (MAC-334IF-E)
- Procon BACnet and Modbus Interface (PAC-UKPRC001-CN-1)
- Thermostat Interface for 3rd Party Thermostats (PAC-US445CN-1)
- Wireless Interface Adapter for the Comfort app (PAC-USWHS002-WF-2)
Wired Remote Controller
- Deluxe Wired MA Remote Controller 1 (PAR-42MAAUB)
- Simple Direct Wired Remote Controller (PAC-SDW01RC-1)
- Simple MA Remote Controller 1 (PAC-YT53CRAU-J)
- Touch MA Wired Remote Controller 1 (PAR-CT01MAU-SB)
Filter
- Electro Static Anti-allergy Enzyme Filter (MAC-2320FT-E)
- Microparticle Filter (MAC-EMF515FT-E)
Condensate
- Blue Diamond (Slim Fascia Kit) Condensate Pump w/ Reservoir & Sensor (X86-011)
- Blue Diamond Advanced Mini Condensate Pump w Reservoir Sensor 208230V recommended (X87-721)
- Blue Diamond MaxiBlue Advanced Mini Condensate Pump w Reservoir Sensor 110V up to 48000 BTUH recommended (X87-711)
- Blue Diamond MegaBlue Advanced Condensate Pump w Reservoir Sensor (X87-835)
- Blue Diamond MicroBlue Mini Condensate Pump 110/208/230V up to 18000 BTUH (X86-003)
- Blue Diamond Sensor Extension Cable 15 Ft (C13-103)
- Drain Pan Level SensorControl (SS610E)
- Refco Condensate Pump 100-240 VAC (GOBI-II)
- Refco Condensate Pump 100-240 VAC up to 120000 BTUH (COMBI)
- Sauermann Condensate Pump (S130-230)
Lineset
- 15 x 1/4 x 15 3/8 Lineset Twin-Tube Insulation (MLS143812T-15)
- 30 x 1/4 x 30 3/8 Lineset Twin-Tube Insulation (MLS143812T-30)
- 50 x 1/4 x 50 3/8 Lineset Twin-Tube Insulation (MLS143812T-50)
- 65 x 1/4 x 65 3/8 Lineset Twin-Tube Insulation (MLS143812T-65)
Disconnect Switch
- 30A 600V UL fits 2 X 4 utility box - Black (TAZ-MS303)
- 30A 600V UL fits 2 X 4 utility box - White (TAZ-MS303W)
Wireless Remote Controller
- Lockdown Bracket for Wireless Handheld Remote Controllers (RCMKP1CB)
- RedLINK Wireless Remote Controller (MHK2)
Remote Sensor
- Remote Temperature Sensor for MFZ, MLZ and MSZ models (M21EAA307)
- Wireless temperature and humidity sensor for the Comfort app (PAC-USWHS003-TH-1)
Power Supplies and Auxiliary Components
- Backup Heat Relay Kit Adapter for CN24 or CN152 Connector (CN24RELAY-KIT-CM3)
Drain Hose
- Flexible Mini-Split Drain Hose (DRX-16)
Outdoor Unit Accessories
Stand
- 18 Single Fan Stand (QSMS1801M)
- 24 Single Fan Stand (QSMS2401M)
- Condenser Wall Bracket (QSWB2000M-1)
- Condenser Wall Bracket - Stainless Steel Finish (QSWBSS)
- Outdoor Unit 3-14 inch Mounting Base Pair - Plastic (DSD-400P)
- Outdoor Unit Stand 12 High (QSMS1201M)
Muffler
- Muffler for Connection to SLZ (MAC-001MF-E)
Mini-Split Wire
- 14 Gauge 4 wire Armored MiniSplit Cable 250 ft roll (SW144-250)
- 14 Gauge 4 wire Armored MiniSplit Cable 50 ft roll (SW144-50)
- 14 Gauge 4 wire MiniSplit Cable 250 ft roll (S144-250)
- 14 Gauge 4 wire MiniSplit Cable 50 ft roll (S144-50)
Drain Socket
- Drain Socket (MAC-871DS)
Mounting Pad
- Condensing Unit Mounting Pad 16 x 36 x 3 (ULTRILITE 1)
Control/Service Tool
- M- & P-Series Maintenance Tool Cable Set (M21EC0397)
- Maintenance Tool Interface (PAC-USCMS-MN-1)
Air Outlet Guide
- Air Outlet Guide (MAC-886SG-E)
Snow/Rain Diverter
- Snow/Rain Diverter (SRD-3)
Indoor Unit Dimensions (MSZ-EX09NLW)
Diagram showing the dimensions of the MSZ-EX09NLW indoor unit. Key dimensions include width, height, depth, and the placement of air intake and outlet, as well as piping and drain hose connections. The diagram also indicates required clearances and installation plate hole dimensions.
MSZ-EX09/12NL Dimensions:
- Piping Insulation: 1-7/16 in O.D.
- Liquid line: 1/4 in (Flared connection 1/4)
- Gas line: 3/8 in (Flared connection 3/8)
- Drain hose: Insulation 1-1/8 in, Connected part 5/8 in O.D., active length 15-3/8 in.
MSZ-EX15/18NL Dimensions:
- Piping Insulation: 1-7/16 in O.D.
- Liquid line: 1/4 in (Flared connection 1/4)
- Gas line: 1/2 in (Flared connection 1/2)
- Drain hose: Insulation 1-1/8 in, Connected part 5/8 in O.D., active length 15-3/8 in.
Note: Extension pipe size refers to the specifications table.
Outdoor Unit Dimensions (SUZ-AA09NLHZ)
Diagram illustrating the required space and dimensions for the SUZ-AA09NLHZ outdoor unit. It shows top, side, and front views with measurements for air intake, air outlet, service panel, valve cover, and pipe joints. Required clearances are indicated for different sides of the unit.
Required Space:
- Basically open: 20 inches or more without any obstruction in front and both sides of the unit.
- Sides: 4 inches or more.
- Rear: 14 inches or more.
- Front: 20 inches or more.
- Open two sides of right or rear side.
Pipe Joint Dimensions:
- Liquid Refrigerant Pipe: FLARED Ø6.35 (1/4")
- Gas Refrigerant Pipe (AA09/12): FLARED Ø9.52 (3/8")
- Gas Refrigerant Pipe (AA15/18): FLARED Ø12.7 (1/2")
- Gas Refrigerant Pipe (AA24/30/36): FLARED Ø15.88 (5/8")
Contact Information:
- Address: 1340 Satellite Boulevard Suwanee, GA 30024
- Toll Free: 800-433-4822
- Website: https://mitsubishicomfort.com
Certifications: AHRi CERTIFIED®, Unitary Small HP, AHR Standard 210/240, C LISTED, Intertek.