Product Data Sheet

Schneider Electric Altivar Process ATV600, ATV630, 250kW, 400hp, 380 to 480V, IP00

Image of the Schneider Electric Altivar Process ATV630 variable speed drive.

Main Specifications

Range of ProductAltivar Process ATV600
Product Specific ApplicationProcess and utilities
Product or Component TypeVariable speed drive
VariantStandard version
Device short nameATV630
Mounting ModeWall mount
Communication Port ProtocolModbus TCP, Modbus serial, Ethernet
[Us] rated supply voltage380...480 V - 15...10%
Relative symmetric mains voltage tolerance10%
Relative symmetric network frequency tolerance5%
nominal output current481.0 A
IP degree of protectionIP21
Product destinationEMC filter Integrated 164.04 ft (50 m) IEC 61800-3 category C3
IP degree of protection (with kit)IP00 IEC 61800-5-1, IP00 IEC 60529, IP21 with kit VW3A9113 IEC 61800-5-1, IP21 with kit VW3A9113 IEC 60529
type of coolingForced convection
Supply frequency50...60 Hz - 5...5%
Motor power kW250 kW normal duty, 220 kW heavy duty
Maximum Horse Power Rating400 hp normal duty, 300 hp heavy duty
Line current451 A 380 V normal duty, 366 A 480 V normal duty, 365 A 380 V heavy duty, 301 A 480 V heavy duty
Continuous output current481 A 2.5 kHz normal duty, 387 A 2.5 kHz heavy duty
Speed drive output frequency0.1...500 Hz
Safety functionSTO (safe torque off) SIL 3

Complementary Specifications

FeatureDetails
Discrete input number8
Discrete input typeD17, DI8 programmable as pulse input 0...30 kHz, 24 V DC <= 30 V
Discrete input logic16 preset speeds
Discrete output number0
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA; Relay outputs R2A, R2C 30 V DC 5000 mA; Relay outputs R3A, R3C 250 V AC 5000 mA; Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number3
Analogue input typeAl1, Al2, Al3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits; Al1, Al2, Al3 software-configurable current 0...20 mA 250 Ohm 12 bits; Al2 voltage analog input -10...10 V DC 31.5 kOhm 12 bits
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits; Software-configurable current AQ1, AQ2 0...20 mA 10 bits; Software-configurable current DQ-, DQ+ 30 V DC; Software-configurable current DQ-, DQ+ 100 mA
Relay output number3
Relay output typeConfigurable relay logic R1 fault relay NO/NC 100000 cycles; Configurable relay logic R2 sequence relay NO 100000 cycles; Configurable relay logic R3 sequence relay NO 100000 cycles
Maximum switching currentRelay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC; Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC; Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC; Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching currentRelay output R1, R2, R3 5 mA 24 V DC
Phase3 phase
Physical interfaceEthernet, 2-wire RS 485
Method of accessSlave Modbus TCP
Transmission Rate10, 100 Mbits
Transmission frameRTU
Output voltage<= power supply voltage
Permissible temporary current boost1.1 x In 60 s normal duty, 1.5 x In 60 s heavy duty
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance
Frequency resolutionDisplay unit 0.1 Hz, Analog input 0.012/50 Hz

Electrical and Control Specifications

FeatureDetails
Electrical connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16; Line side screw terminal 4 x 185 mm² 3 x 350 kcmil; Motor screw terminal 4 x 185 mm² 3 x 350 kcmil
Connector typeRJ45 on the remote graphic terminal Ethernet/Modbus TCP; RJ45 on the remote graphic terminal Modbus serial
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses1...247 Modbus serial
SupplyExternal supply for digital inputs 24 V DC 19...30 V), <1.25 mA overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5%, <10 mA overload and short-circuit protection; Internal supply for digital inputs and STO 24 V DC 21...27 V), <200 mA overload and short-circuit protection
Local signalling3 LEDs for local diagnostic; 3 LEDs (dual colour) for embedded communication status; 4 LEDs (dual colour) for communication module status; 1 LED (red) for presence of voltage
Input compatibilityDI1...DI6 discrete input level 1 PLC IEC 61131-2; D15, D16 discrete input level 1 PLC IEC 65A-68; STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete input logicPositive logic (source) DI1...DI8), < 5 V, > 11 V; Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Sampling duration2 ms +/- 0.5 ms DI1...DI4) - discrete input; 5 ms +/- 1 ms DI5, DI6) - discrete input; 5 ms +/- 0.1 ms Al1, Al2, A13) - analog input; 10 ms +/- 1 ms AO1) - analog output
Accuracy+/- 0.6% Al1, Al2, Al3 for a temperature variation 60 °C analog input; +/-1% AO1, AO2 for a temperature variation 60 °C analog output
Linearity errorAl1, Al2, Al3 +/- 0.15% of maximum value analog input; AO1, AO2 +/- 0.2% analog output
Refresh timeRelay output R1, R2, R3) 5 ms +/- 0.5 ms
IsolationBetween power and control terminals
Discrete and process manufacturing applicationsBuilding - HVAC compressor centrifugal; Food and beverage processing other application; Mining mineral and metal fan; Mining mineral and metal pump; Oil and gas fan; Water and waste water other application; Building - HVAC screw compressor; Food and beverage processing pump; Food and beverage processing fan; Food and beverage processing atomization; Oil and gas electro submersible pump (ESP); Oil and gas water injection pump; Oil and gas jet fuel pump; Oil and gas compressor for refinery; Water and waste water centrifuge pump; Water and waste water positive displacement pump; Water and waste water electro submersible pump (ESP); Water and waste water screw pump; Water and waste water lobe compressor; Water and waste water screw compressor; Water and waste water compressor centrifugal; Water and waste water fan; Water and waste water conveyor; Water and waste water mixer
Power range250...500 kW 380...440 V 3 phase; 250...500 kW 480...500 V 3 phase
Enclosure mountingWall mounted
4 quadrant operation possibleFalse
Asynchronous motor control profileVariable torque standard; Constant torque standard; Optimized torque mode
Synchronous motor control profilePermanent magnet motor; Synchronous reluctance motor
Maximum output frequency500 kHz
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Motor slip compensationAutomatic whatever the load; Not available in permanent magnet motor law; Can be suppressed
Switching frequency2.5...8 kHz with derating factor; 2...8 kHz adjustable
Nominal switching frequency2.5 kHz
Braking to standstillBy DC injection
Brake chopper integratedFalse
Maximum Input Current per Phase451.0 A
Maximum output voltage480.0 V
Apparent power279 kVA 480 V normal duty; 229 kVA 480 V heavy duty
Maximum transient current529 A 60 s normal duty; 581 A 60 s heavy duty
Network Frequency50-60 Hz
Prospective line Isc50 kA
Base load current at high overload387.0 A
Base load current at low overload481.0 A
Power dissipation in WForced convection 5773 W; Natural convection 606 W 380 V 2.5 kHz
Safety FunctionsSafely Limited Speed (SLS): False; Safe brake management (SBC/SBT): False; Safe Operating Stop (SOS): False; Safe Position (SP): False; Safe programmable logic: False; Safe Speed Monitor (SSM): False; Safe Stop 1 (SS1): False; Safe Stop 2 (SS2): False; Safe torque off (STO): True; Safely Limited Position (SLP): False; Safe Direction (SDI): False

Environment and Certifications

FeatureDetails
Protection typeThermal protection motor; Safe torque off motor; Motor phase break motor; Thermal protection drive; Safe torque off drive; Overheating drive; Overcurrent between output phases and earth drive; Overload of output voltage drive; Short-circuit protection drive; Motor phase break drive; Overvoltages on the DC bus drive; Line supply overvoltage drive; Line supply undervoltage drive; Line supply phase loss drive; Overspeed drive; Break on the control circuit drive
Quantity per Set1
Dimensions (W x H x D)23.5 in (598 mm) x 47.05 in (1195 mm) x 15.0 in (380 mm)
Net Weight447.5 lb(US) (203 kg)
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Noise level68 dB IEC 60068-2-6
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn 11 ms IEC 60068-2-27
Relative humidity5...95% without condensation IEC 60068-2-3
Ambient air temperature for operation14...104 °F (-10...40 °C) (without derating); 104...140 °F (40...60 °C) (with derating factor)
Operating altitude<= 3280.84 ft (1000 m) without derating; 3280.84...9842.52 ft (1000...3000 m) with current derating 1% per 100 m
Operating positionVertical +/- 10 degree
Product CertificationsCSA, UL, TÜV, CE
MarkingCF
StandardsUL 508C; IEC 61800-3; EN/IEC 61800-3 environment 1 category C2; EN/IEC 61800-3 environment 2 category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1
Maximum THDI<48% full load IEC 61000-3-12
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 μs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Environmental footprintCarbon footprint (kg CO2 eq, Total Life cycle): 184862
Materials and SubstancesPackaging made with recycled cardboard: Yes; Packaging without single use plastic: No; EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope); SCIP Number: 405cb612-8eb2-47cb-8883-95e373eada5f; REACH Regulation: REACH Declaration; California proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Energy efficiencyProduct contributes to saved and avoided emissions: Yes
Repack and remanufactureNo
Take-backThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
WEEENo

Dimensions and Mounting

Dimensions

Diagrams showing rear, right, and front views of the drive with dimensions.

ViewWidthHeightDepth
Rear540 mm (21.26 in)920 mm (36.22 in)150 mm (5.91 in)
Right Side379.88 mm (14.96 in)N/A377.38 mm (14.86 in)
Front598 mm (23.54 in)1195.38 mm (47.06 in)N/A

Mounting and Clearance

Diagram illustrating required clearances for mounting.

ClearanceRequirement
X1≥ 200 mm (7.87 in.)
X2≥ 150 mm (5.91 in.)
X3≥ 10 mm (0.39 in.)

Diagrams showing different mounting types.

Mounting Type A: Individual IP21

Description: Individual mounting with IP21 protection. Units can be installed side-by-side with a minimum spacing 'a' (a ≥ 0).

Mounting Type B: Side by Side IP20

Description: Side-by-side mounting with IP20 protection.

Mounting Type C: Individual IP20

Description: Individual mounting with IP20 protection. Units can be installed side-by-side with a minimum spacing 'a' (a ≥ 0).

Connections and Schema

Three-Phase Power Supply with Upstream Breaking via Line Contactor

Connection diagram showing upstream breaking using a line contactor (KM1), circuit breakers (Q2, Q3), pushbuttons (S1, S2), and transformer (T1). Relay R1 is used for fault indication.

Three-Phase Power Supply with Downstream Breaking via Contactor

Connection diagram showing downstream breaking using a contactor (KM1) placed after the drive.

Control Block Wiring Diagram

Diagram illustrating the control block wiring. Shows connections for digital inputs (DI1-DI6), Safe Torque Off (STO) inputs (STOA, STOB), 24V supply, analog inputs (AI1, AI2, AI3), analog outputs (AQ1, AQ2), and relay outputs (R1A/R1B/R1C, R2A/R2C, R3A/R3C).

Sensor Connection: It is possible to connect either 1 or 3 sensors on terminals AI2 or AI3.

Sink / Source Switch Configuration

This switch adapts the operation of the logic inputs to the technology of the programmable controller outputs.

  • Set the switch to Source (factory setting) if using PLC outputs with PNP transistors.
  • Set the switch to Ext if using PLC outputs with NPN transistors.

Diagrams illustrating different switch configurations: SRC (Source) with output power supply, SRC (Source) with external power supply, SK (Sink) with output power supply, and EXT (External) with external power supply for Digital Inputs (DIs).

Performance Curves

Derating Curves

Graph showing derating curves for Nominal Drive Current (In) versus Switching Frequency (SF) at different ambient temperatures (40°C, 50°C, 60°C).

Ordering and Shipping Details

FeatureDetails
CategoryUS1CP4E22207
Discount ScheduleCP4E
GTIN3606481154729
ReturnabilityYes
Country of originID

Packing Units

Package DetailValue
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.96 in (38.000 cm)
Package 1 Width23.54 in (59.800 cm)
Package 1 Length47.05 in (119.500 cm)
Package 1 Weight500.450 lb(US) (227.000 kg)

PDF preview unavailable. Download the PDF instead.

Generatepdf.aspx?salesorgid=78&dist=849&lang=42&form=no&documenttype=plain&productid=ATV630C25N4 cairo 1.15.12 (http://cairographics.org)

Related Documents

Preview Schneider Electric Altivar Process ATV630D18Y6 Variable Speed Drive - 18.5kW, 690V
Technical data sheet for the Schneider Electric Altivar Process ATV630D18Y6 variable speed drive, detailing specifications, features, dimensions, environmental data, and ordering information for this 18.5kW (25hp), 690V industrial AC drive.
Preview Schneider Electric Altivar Process ATV630 Variable Speed Drive - 2.2kW, 3hp, 500-690V, IP00
Detailed product data sheet for the Schneider Electric Altivar Process ATV630 variable speed drive. Includes specifications, electrical data, environmental information, dimensions, mounting types, connection diagrams, and performance curves for the ATV630U22Y6 model.
Preview Schneider Electric Altivar Process ATV630, 4kW Variable Speed Drive - Product Data Sheet
Detailed product data sheet for the Schneider Electric Altivar Process ATV630, a 4kW variable speed drive. Includes specifications, dimensions, mounting types, electrical connections, performance curves, and environmental data.
Preview Schneider Electric Altivar Process ATV630D18N4 Variable Speed Drive - Technical Data
Detailed technical specifications for the Schneider Electric Altivar Process ATV630D18N4 variable speed drive, including electrical, environmental, and performance data. This 18.5kW (25hp) drive operates at 380-480V with IP21 protection and UL Type 1 rating.
Preview Schneider Electric Altivar Process ATV630 Variable Speed Drive - Product Data Sheet
Detailed technical specifications, dimensions, environmental data, and connection diagrams for the Schneider Electric Altivar Process ATV630 variable speed drive, including models ATV600, ATV630, 55kW, 75hp, 500-690V, IP00.
Preview Schneider Electric Altivar Process ATV630D30Y6 Variable Speed Drive Data Sheet
Detailed technical specifications and data for the Schneider Electric Altivar Process ATV630D30Y6 variable speed drive, including electrical characteristics, performance curves, dimensions, and environmental data.
Preview Schneider Electric Altivar Process ATV630U55S6X Variable Speed Drive Data Sheet
Comprehensive data sheet for the Schneider Electric Altivar Process ATV630U55S6X variable speed drive, detailing specifications, features, dimensions, environmental data, and electrical connections for a 7.5hp, 600V, IP21 rated drive.
Preview Schneider Electric Altivar Process ATV600, ATV630, 45kW Variable Speed Drive Data Sheet
Detailed technical specifications for the Schneider Electric Altivar Process ATV600 and ATV630 variable speed drives, including power ratings, electrical characteristics, environmental data, and dimensions.