Schneider Electric Altivar Process ATV630D18N4
Variable Speed Drive
Product Specifications: 18.5kW, 25hp, 380 to 480V, IP21, UL Type 1
Main Specifications
Range of Product | Altivar Process ATV600 |
Product Specific Application | Process and utilities |
Product or Component Type | Variable speed drive |
Variant | Standard version |
Device short name | ATV630 |
Mounting Mode | Wall mount |
Communication Port Protocol | Modbus TCP, Modbus serial, Ethernet |
[Us] rated supply voltage | 380...480 V - 15...10% |
[Us] rated supply voltage | 380...480 V |
Relative symmetric mains voltage tolerance | 10% |
Relative symmetric network frequency tolerance | 5% |
Nominal output current | 39.2 A |
IP degree of protection | IP21 |
Product destination | Asynchronous motors, Synchronous motors |
EMC filter | Integrated 164.04 ft (50 m) IEC 61800-3 category C2, Integrated 492.1 ft (150 m) IEC 61800-3 category C3 |
IP degree of protection | IP21 IEC 61800-5-1 |
Degree of protection | IP21 IEC 60529, UL type 1 UL 508C |
Type of cooling | Forced convection |
Supply frequency | 50...60 Hz - 5...5% |
Motor power kW | 18.5 kW (normal duty), 15 kW (heavy duty) |
Maximum Horse Power Rating | 25 hp (normal duty), 20 hp (heavy duty) |
Line current | 33.4 A (380 V normal duty), 28.9 A (480 V normal duty), 27.7 A (380 V heavy duty), 24.4 A (480 V heavy duty) |
Continuous output current | 39.2 A (4 kHz normal duty), 31.7 A (4 kHz heavy duty) |
Speed drive output frequency | 0.1...500 Hz |
Safety function | STO (safe torque off) SIL 3 |
Complementary Specifications
Discrete input number | 8 |
Discrete input type | DI1...DI6: Programmable as pulse input 0...30 kHz, 24 V DC (<= 30 V) |
Discrete input logic | 16 preset speeds |
Discrete output number | 0 |
Discrete output type | Relay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA; Relay outputs R2A, R2C 30 V DC 5000 mA; Relay outputs R3A, R3C 250 V AC 5000 mA; Relay outputs R3A, R3C 30 V DC 5000 mA |
Analogue input number | 3 |
Analogue input type | Al1, Al2, Al3 software-configurable voltage 0...10 V DC (31.5 kOhm, 12 bits); Al1, Al2, Al3 software-configurable current 0...20 mA (250 Ohm, 12 bits); Al2 voltage analog input -10...10 V DC (31.5 kOhm, 12 bits) |
Analogue output number | 2 |
Analogue output type | Software-configurable voltage AQ1, AQ2 0...10 V DC (470 Ohm, 10 bits); Software-configurable current AQ1, AQ2 0...20 mA (10 bits) |
Relay output number | 3 |
Relay output type | Configurable relay logic R1 fault relay NO/NC (100000 cycles); Configurable relay logic R2 sequence relay NO (100000 cycles); Configurable relay logic R3 sequence relay NO (100000 cycles) |
Maximum switching current | Relay output R1, R2, R3 resistive, cos phi = 1: 3 A 250 V AC; Relay output R1, R2, R3 resistive, cos phi = 1: 3 A 30 V DC; Relay output R1, R2, R3 inductive, cos phi = 0.4 (7 ms): 2 A 250 V AC; Relay output R1, R2, R3 inductive, cos phi = 0.4 (7 ms): 2 A 30 V DC; Relay output R1, R2, R3: 5 mA 24 V DC |
Minimum switching current | Relay output R1, R2, R3: 5 mA 24 V DC |
Phase | 3 phase |
Physical interface | Ethernet |
Method of access | 2-wire RS 485, Slave Modbus TCP |
Transmission Rate | 10, 100 Mbits; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps |
Transmission frame | RTU |
Output voltage | <= power supply voltage |
Permissible temporary current boost | 1.1 x In (60 s, normal duty); 1.5 x In (60 s, heavy duty) |
Data format | 8 bits, configurable odd, even or no parity |
Type of polarization | No impedance |
Frequency resolution | Display unit: 0.1 Hz; Analog input: 0.012/50 Hz |
Electrical Characteristics
Electrical connection | Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16; Line side screw terminal 10...16 mm² AWG 8...AWG 6; Motor screw terminal 10...16 mm² AWG 8...AWG 6 |
Connector type | RJ45 on the remote graphic terminal: Ethernet/Modbus TCP; RJ45 on the remote graphic terminal: Modbus serial |
Exchange mode | Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
Number of addresses | 1...247 Modbus serial |
Supply | External supply for digital inputs 24 V DC (19...30 V), <1.25 mA overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5%, <10 mA overload and short-circuit protection; Internal supply for digital inputs and STO 24 V DC (21...27 V), <200 mA overload and short-circuit protection |
Local signalling | 3 LEDs for local diagnostic; 3 LEDs (dual colour) for embedded communication status; 4 LEDs (dual colour) for communication module status; 1 LED (red) for presence of voltage |
Input compatibility | DI1...DI6 discrete input level 1 PLC IEC 61131-2; D15, D16 discrete input level 1 PLC IEC 65A-68; STOA, STOB discrete input level 1 PLC IEC 61131-2 |
Discrete input logic | Positive logic (source) DI1...DI8), < 5 V, > 11 V; Negative logic (sink) DI1...DI8), > 16 V, < 10 V |
Sampling duration | 2 ms +/- 0.5 ms (DI1...DI4) - discrete input; 5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 0.1 ms (Al1, Al2, A13) - analog input; 10 ms +/- 1 ms (AO1) - analog output |
Accuracy | +/- 0.6% Al1, Al2, Al3 for a temperature variation 60 °C analog input; +/-1% AO1, AO2 for a temperature variation 60 °C analog output |
Linearity error | Al1, Al2, Al3 +/- 0.15% of maximum value analog input; AO1, AO2 +/- 0.2% analog output |
Refresh time | Relay output R1, R2, R3: 5 ms +/- 0.5 ms |
Isolation | Between power and control terminals |
Environmental Data
Environment |
|
Product Certifications and Standards
Product Certifications | CSA, ATEX zone 2/22, ATEX INERIS, DNV-GL, UL, TÜV |
Marking | CE |
Standards | UL 508C; IEC 61800-3; EN/IEC 61800-3 environment 1 category C2; EN/IEC 61800-3 environment 2 category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1 |
Maximum THDI | <48% from 80...100% of load IEC 61000-3-12 |
Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 μs - 8/20 μs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
Dimensions
Drives with IP21 Top Cover
Front and Left Views:
Width: 8.3 in (211 mm)
Depth: 9.13 in (232 mm)
Height: 21.5 in (545.9 mm)
Drives Without IP21 Top Cover
Left and Rear Views:
Width: 7.7 in (195 mm)
Depth: 9.13 in (232 mm)
Height: 21.5 in (545.9 mm)
Dimensions (Alternate Views)
Width: 9 in (228.3 mm)
Depth: 8.68 in (220.5 mm)
Height: 8.27 in (210 mm) to 8.72 in (221.5 mm)
Mounting and Clearance
Clearances
X1: ≥ 100 mm (3.94 in.)
X2: ≥ 100 mm (3.94 in.)
X3: ≥ 10 mm (0.39 in.)
Mounting Types
Mounting Type A: Individual IP21
Requires clearance 'a' ≥ 100 mm (3.94 in.)
Mounting Type B: Side by Side IP20
Mounting Type C: Individual IP20
Requires clearance 'a' ≥ 0
Connections and Schema
Three-Phase Power Supply with Upstream Breaking via Line Contactor
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1.
Diagram Description:
The diagram shows a three-phase power supply connected to the drive (ATV6) via a line contactor (KM1). It includes circuit breakers (Q2, Q3), pushbuttons (S1, S2), and a transformer (T1) for the control part. Notes indicate that a line choke may be used, and relay R1 can be set to the 'Fault' state to switch off the product upon error detection.
Three-Phase Power Supply with Downstream Breaking via Contactor
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1.
Diagram Description:
Similar to the upstream breaking diagram, this shows a three-phase power supply with downstream breaking via a contactor. It also includes circuit breakers, pushbuttons, and a control transformer. Notes regarding line choke usage and relay R1 function for error detection are present.
Control Block Wiring Diagram
The diagram illustrates the control block wiring for the drive, showing connections for digital inputs (DI1-DI6), analog inputs (AI1-AI3), analog outputs (AQ1-AQ2), and safety functions like Safe Torque Off (STO). It also details relay connections (R1A, R1B, R1C; R2A, R2C; R3A, R3C) and a reference potentiometer connection.
Sensor Connection: It is possible to connect either 1 or 3 sensors on terminals Al2 or Al3.
Sink / Source Switch Configuration
This switch adapts the operation of logic inputs to the technology of the programmable controller outputs.
- Set the switch to Source (factory setting) if using PLC outputs with PNP transistors.
- Set the switch to Ext if using PLC outputs with NPN transistors.
Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs
Diagram showing digital inputs connected to the drive with the switch in the SRC position, using the drive's output power supply.
Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs
Diagram showing digital inputs connected to the drive with the switch in the SRC position, using an external power supply.
Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs
Diagram showing digital inputs connected to the drive with the switch in the SK position, using the drive's output power supply.
Switch Set to EXT Position Using an External Power Supply for the DIs
Diagram showing digital inputs connected to the drive with the switch in the EXT position, using an external power supply.
Performance Curves
Derating Curves
The graph shows derating curves based on ambient temperature and switching frequency (SF) for different mounting types (A, B, C).
- 40 °C (104 °F) - Mounting type A, B and C
- 50 °C (122 °F) - Mounting type A, B and C
- 60 °C (140 °F) - Mounting type B and C
Legend:
In: Nominal Drive Current
SF: Switching Frequency
Environmental Data Summary
Schneider Electric aims to achieve Net Zero status by 2050. This product's environmental footprint includes a carbon footprint of 18275 kg CO2 eq (Total Life cycle). The packaging is made with recycled cardboard and without single-use plastic. The product complies with EU RoHS Directive and REACH regulations. California Proposition 65 warning applies regarding lead exposure.
Energy Efficiency: The product contributes to saved and avoided emissions.
Circularity: The product must be disposed of in European Union markets following specific waste collection and never end up in rubbish bins.
Ordering and Shipping Details
Category | US1CP4E22206 |
Discount Schedule | CP4E |
GTIN | 3606480701399 |
Returnability | Yes |
Country of origin | IN |
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 13.19 in (33.500 cm)
Package 1 Width: 10.24 in (26.000 cm)
Package 1 Length: 28.94 in (73.500 cm)
Package 1 Weight: 37.966 lb(US) (17.221 kg)
Unit Type of Package 2: P06
Number of Units in Package 2: 4
Package 2 Height: 35.43 in (90.000 cm)
Package 2 Width: 23.62 in (60.000 cm)
Package 2 Length: 31.50 in (80.000 cm)
Package 2 Weight: 178.839 lb(US) (81.120 kg)