Schneider Electric Altivar Process ATV630 Variable Speed Drive
Product Data Sheet for ATV630U22Y6
Specifications
Product Name: Altivar Process ATV630
Product Type: Variable speed drive
Variant: Standard version
Device Short Name: ATV630
Mounting Mode: Wall mount
Communication Port Protocol: Ethernet, Modbus serial, Modbus TCP
Rated Supply Voltage: 500...690 V
Relative Symmetric Mains Voltage Tolerance: ±10%
Relative Symmetric Network Frequency Tolerance: ±5%
Nominal Output Current: 3.1 A
Degree of Protection: IP00 (IEC 61800-5-1), IP20 (with kit VW3A9705)
Product Destination: Asynchronous motors, Synchronous motors
EMC Filter: Integrated 82.02 ft (25 m) IEC 61800-3 category C3
Type of Cooling: Forced convection
Supply Frequency: 50...60 Hz
Motor Power (kW): 1.5 kW (500 V normal duty), 1.1 kW (500 V heavy duty), 2.2 kW (690 V normal duty), 1.5 kW (690 V heavy duty)
Maximum Horse Power Rating: 2 hp (500 V normal duty), 1.5 hp (500 V heavy duty), 3 hp (690 V normal duty), 2 hp (690 V heavy duty)
Line Current: 3.4 A (500 V normal duty), 3.6 A (690 V normal duty), 2.6 A (500 V heavy duty), 2.6 A (690 V heavy duty)
Continuous Output Current: 3.1 A (4 kHz normal duty), 2.4 A (4 kHz heavy duty)
Complementary Specifications
Discrete Input Number: 8
Discrete Input Type: DI1-DI8 programmable as pulse input (0...30 kHz, 24 V DC)
Discrete Input Logic: 16 preset speeds
Discrete Output Number: 0
Discrete Output Type: Relay outputs (R1A, R1B, R1C; R2A, R2C; R3A, R3C) with various voltage and current ratings.
Analogue Input Number: 3
Analogue Input Type: Software-configurable voltage (0...10 V DC) or current (0...20 mA)
Analogue Output Number: 2
Analogue Output Type: Software-configurable voltage (0...10 V DC) or current (0...20 mA)
Relay Output Number: 3
Relay Output Type: Configurable relay logic (R1 fault relay, R2/R3 sequence relay)
Maximum Switching Current: 3 A (resistive, cos phi = 1)
Minimum Switching Current: 5 mA (24 V DC)
Phase: 3 phase
Physical Interface: Ethernet, 2-wire RS 485
Method of Access: Slave Modbus TCP
Transmission Rate: 10, 100 Mbits
Transmission Frame: RTU
Permissible Temporary Current Boost: 1.1 x In (60 s normal duty), 1.5 x In (60 s heavy duty)
Data Format: 8 bits, configurable parity
Electrical Characteristics
Type of Polarization: No impedance
Frequency Resolution: Display unit 0.1 Hz, Analog input 0.012/50 Hz
Electrical Connection: Control removable screw terminals (0.5...1.5 mm²), Motor screw terminal (4...10 mm²), Line side screw terminal (4...10 mm²)
Connector Type: RJ45
Exchange Mode: Half duplex, full duplex, autonegotiation
Number of Addresses: 1...247 (Modbus serial)
Supply: External supply for digital inputs (24 V DC, 19...30 V), <1.25 mA; Internal supply for reference potentiometer (10.5 V DC +/- 5%), <10 mA; Internal supply for digital inputs and STO (24 V DC, 21...27 V), <200 mA
Local Signalling: 3 LEDs for local diagnostic, 3 LEDs for embedded communication status, 4 LEDs for communication module status, 1 LED for presence of voltage.
Input Compatibility: DI1-DI6 level 1 PLC IEC 61131-2; STOA, STOB level 1 PLC IEC 61131-2
Discrete Input Logic: Positive logic (source) or Negative logic (sink)
Sampling Duration: 2 ms +/- 0.5 ms (DI1-DI4), 5 ms +/- 1 ms (DI5, DI6), 5 ms +/- 0.1 ms (Al1, Al2, Al3), 10 ms +/- 1 ms (AO1)
Accuracy: +/- 0.6% (Al1, Al2, Al3) for temperature variation; +/-1% (AO1, AO2) for temperature variation
Linearity Error: +/- 0.15% (analog input), +/- 0.2% (analog output)
Refresh Time: Relay output R1, R2, R3: 5 ms +/- 0.5 ms
Isolation: Between power and control terminals
Enclosure Mounting: Wall mounted
4 Quadrant Operation Possible: False
Asynchronous Motor Control Profile: Optimized torque mode, Variable torque standard, Constant torque standard
Synchronous Motor Control Profile: Permanent magnet motor, Synchronous reluctance motor
Maximum Output Frequency: 500 kHz
Acceleration and Deceleration Ramps: S, U or customized, Linear adjustable separately from 0.01...9999 s
Motor Slip Compensation: Adjustable
Switching Frequency: 2...8 kHz adjustable (4...8 kHz with derating factor)
Nominal Switching Frequency: 4 kHz
Braking to Standstill: By DC injection
Brake Chopper Integrated: False
Environmental Data
Environmental Footprint: Carbon footprint: 2901 kg CO2 eq. (Total Life cycle)
Materials and Substances: Packaging made with recycled cardboard: Yes. Packaging without single use plastic: No.
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
SCIP Number: 075941f9-bf60-4e63-ae5c-6fe3c8035357
REACH Regulation: REACH Declaration
California Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Energy Efficiency: Product contributes to saved and avoided emissions: Yes
Circularity Profile: Take-back: No. WEEE: The product must be disposed of in European Union markets following specific waste collection and never end up in rubbish bins.
Dimensions
Width: 9.7 in (246 mm)
Height: 16.5 in (420 mm)
Depth: 9.5 in (242 mm)
Product Weight: 48.5 lb(US) (22 kg)
Mounting and Clearances
Clearances:
- X1 (Top/Bottom): ≥ 100 mm (3.94 in.)
- X2 (Sides): ≥ 100 mm (3.94 in.)
- X3 (Rear): ≥ 10 mm (0.39 in.)
Mounting Types:
- Mounting Type A: Individual IP21 (requires clearance 'a' ≥ 0)
- Mounting Type B: Side by Side IP20
- Mounting Type C: Individual IP20 (requires clearance 'a' ≥ 0)
Connections and Schemas
Three-Phase Power Supply with Upstream Breaking via Line Contactor
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1.
Diagram Description: Shows a three-phase power supply connected through a line contactor (KM1), circuit breakers (Q2, Q3), and pushbuttons (S1, S2). Includes a line choke (if used) and a transformer for the control part (T1). Relay R1 is used for fault detection.
Three-Phase Power Supply with Downstream Breaking via Contactor
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1.
Diagram Description: Similar to the upstream breaking diagram, but the contactor (KM1) is placed downstream of the drive.
Control Block Wiring Diagram
Diagram Description: Illustrates the wiring for digital inputs (DI1-DI6), digital outputs (STO A, STO B), analog inputs (AI1, AI2, AI3), analog outputs (AQ1, AQ2), and relay outputs (R1A, R1B, R1C; R2A, R2C; R3A, R3C). It also shows connections for a reference potentiometer and external power supply.
Sensor Connection: It is possible to connect either 1 or 3 sensors on terminals Al2 or Al3.
Sink / Source Switch Configuration
This switch adapts the operation of the logic inputs to the technology of the programmable controller outputs.
- Set to Source (factory setting) for PLC outputs with PNP transistors.
- Set to Ext for PLC outputs with NPN transistors.
Diagrams illustrate:
- Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs
- Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs
- Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs
- Switch Set to EXT Position Using an External Power Supply for the DIs
Performance Curves
Derating Curves
The graph shows derating curves based on ambient temperature and switching frequency for mounting types A, B, and C.
- 40 °C (104 °F) - Mounting type A, B and C
- 50 °C (122 °F) - Mounting type A, B and C
- 60 °C (140 °F) - Mounting type B and C
In: Nominal Drive Current
SF: Switching Frequency
Ordering and Shipping Details
Category: US1CP4E22276
Discount Schedule: CP4E
GTIN: 3606481325099
Returnability: No
Country of Origin: IN
Packing Units:
- Unit Type of Package 1: PCE
- Number of Units in Package 1: 1
- Package 1 Height: 18.90 in (48.000 cm)
- Package 1 Width: 15.75 in (40.000 cm)
- Package 1 Length: 31.50 in (80.000 cm)
- Package 1 Weight: 70.548 lb(US) (32.000 kg)